Type MP-GC Three-Conductor Mine Power Feeder Cable, CPE Jacket, 15kV To ICEA S-75-381

Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Sheath, 5kV ICEA S-75-381ApplicationsThese cables are designed for connections between units of mine distribution systems, suitable forinstalled in duct, conduit or open air and for direct burial in wet and dry locations.StandardsICEA S-75-381/NEMA WC 58ASTM B-8CAN/CSA-C22.2 No.96ConstructionConductorsStranded annealed bare copper conductor.Conductor ShieldConducting layer.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldConducting layer + copper tape.Ground Check ConductorCopper conductor with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketChlorinated Polyethylene(CPE), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 12×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround CheckConductor SizeNominal Insulation ThicknessNominal JacketThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×671080.092.30.112.81.3033.×47880.092.30.112.81.4135.×27680.092.30.112.81.4737.×119580.092.30.112.81.5439.×1/019480.092.30.112.81.6341.×2/019380.092.30.112.81.7243.×3/019280.092.30.143.61.8948.×4/019180.092.30.143.62.0151.×250371/080.092.30.143.62.1053.×350372/080.092.30.143.62.3158.×500374/080.092.30.143.62.5965.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Other supplier products
|
|
|
(N)TSCGECWOEU Medium-Voltage Trailing Cable VDE 0250 Part 813ApplicationsThese cables are used for the connection of electrical equipment,Website:,... |
|
|
|
VDE Standard Industrial Cables H05Z-K/H07Z-KApplication and DescriptionThese cables are designed for tde internal wiring of switchboards and distri... |
|
|
|
NSSHOEU-O/J 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812ApplicationsThese cables are designed for the connection of mobile equipment and mac... |
|
|
|
300/500V Mica+XLPE Insulated Individual And Overall Screened fire resistant Instrumentation CablesRE-2X(St)H PiMF...CI. FE 180 PH30 ( CU/MGT+XLPE/I... |
|
|
|
0.6/1KV [FA-] DPY,Website:, TPY, FPY, 5PY, 6PY [FA-] DPYC, TPYC, FPYC, 5PYC, 6PYC [FA-] DPYCY, TPYCY, FPYCY, 5PYCY, 6PYCYStandards:JISC 3410-1999
... |