Type MP-GC Three-Conductor Mine Power Feeder Cable, CPE Jacket, 15kV To ICEA S-75-381

Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Sheath, 5kV ICEA S-75-381ApplicationsThese cables are designed for connections between units of mine distribution systems, suitable forinstalled in duct, conduit or open air and for direct burial in wet and dry locations.StandardsICEA S-75-381/NEMA WC 58ASTM B-8CAN/CSA-C22.2 No.96ConstructionConductorsStranded annealed bare copper conductor.Conductor ShieldConducting layer.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldConducting layer + copper tape.Ground Check ConductorCopper conductor with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketChlorinated Polyethylene(CPE), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 12×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround CheckConductor SizeNominal Insulation ThicknessNominal JacketThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×671080.092.30.112.81.3033.×47880.092.30.112.81.4135.×27680.092.30.112.81.4737.×119580.092.30.112.81.5439.×1/019480.092.30.112.81.6341.×2/019380.092.30.112.81.7243.×3/019280.092.30.143.61.8948.×4/019180.092.30.143.62.0151.×250371/080.092.30.143.62.1053.×350372/080.092.30.143.62.3158.×500374/080.092.30.143.62.5965.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Other supplier products
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8334ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
Type W Two-Conductor Round Portable Power Cable 2kVApplicationsThese cables are designed for general use where baregrounding conductors are not req... |
|
|
|
German Standard Industrial Cables NYCWYApplication and DescriptionNYCWY Power cables is for energy supply,Website:, preferably used for underground... |
|
|
|
Multipair Individually Screened Cables-Belden Equivalent 9732ApplicationsThese cables have individually screened pairs laid up. Each individually s... |
|
|
|
Type 275 1.1/1.1KV to AS/NZS 1802ApplicationsThese cables are mainly used as a flexible feeder for shuttle cars and pump. Earth cores designed to r... |