Type MP-GC Three-Conductor Mine Power Feeder Cable, CPE Jacket, 15kV To ICEA S-75-381

Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Sheath, 5kV ICEA S-75-381ApplicationsThese cables are designed for connections between units of mine distribution systems, suitable forinstalled in duct, conduit or open air and for direct burial in wet and dry locations.StandardsICEA S-75-381/NEMA WC 58ASTM B-8CAN/CSA-C22.2 No.96ConstructionConductorsStranded annealed bare copper conductor.Conductor ShieldConducting layer.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldConducting layer + copper tape.Ground Check ConductorCopper conductor with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketChlorinated Polyethylene(CPE), black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 12×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround CheckConductor SizeNominal Insulation ThicknessNominal JacketThicknessNominal Overall DiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×671080.092.30.112.81.3033.×47880.092.30.112.81.4135.×27680.092.30.112.81.4737.×119580.092.30.112.81.5439.×1/019480.092.30.112.81.6341.×2/019380.092.30.112.81.7243.×3/019280.092.30.143.61.8948.×4/019180.092.30.143.62.0151.×250371/080.092.30.143.62.1053.×350372/080.092.30.143.62.3158.×500374/080.092.30.143.62.5965.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Other supplier products
|
|
|
CAN BUS CABLES 120ΩApplicationThese cables are dedicated to the shipbuilding industry.StandardsIEC 60092-350/351/352/353/359/370/376IEC 60332-1-2IE... |
|
|
|
(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber OpticsApplicationsThese cables are used for For laying alongside the conveyor belts... |
|
|
|
Fire Resistant RS485 Databus Cables Application:The cables are designed for RS485 data connections where continued functionality is required during... |
|
|
|
300/500V Mica+XLPE or SR Insulated & Overall screened Multicore fire resistant Instrumentation cablesRE-2X(St)H...CI. FE 180 PH30 ( CU/MGT+XLPE/OS/... |
|
|
|
Harmonized Code Industrial Cables H05V-R/H07V-RApplication and DescriptionThese cables are preferably for installation indoors,Website:, in cable d... |