Type 455 3.3 To 33KV To AS/NZS 2802

Type 455 3.3 to 33KV to AS/NZS 2802ApplicationsThese cables are designed with reduced insulation and sheath thickness,Website:, no cradle, 2 earth and 1 pilotcore (each earth and pilot are the same size) in the outer interstices. These cablesare suitable for reeling and trailingapplications where minimal diameter and mass is desired, particularly suited to stacker-reclaimer applications.StandardsAS/NZS 2802:2000AS/NZS 1125AS/NZS 3808AS/NZS 5000.1Construction3×ConductorsFlexible stranded tinned annealed copper conductor.Conductor ScreenSemiconductive compound (for cables having a voltage rating of 3.3/3.3kV and above).InsulationEPR.Insulation ScreenSemiconductive elastomer.FillerElastomer centre filler.2×Interstitial Earth ConductorCSP insulated flexible stranded tinned copper conductor.1×Interstitial PilotEPR covered flexible stranded tinned copper conductor.Textile ReinforcementOpen-weave braid reinforcement.SheathExtra-heavy duty PCP sheath.Extra-heavy duty CPE/CSP sheath can be offered upon request.Dimensions and WeightNominal Conductor AreaStrand SizeInsulation ThicknessPilot/Earth ConductorThickness of SheathNominal Overall DiameterNominal WeightStrand SizeThickness of Coveringmm2No/mmmmNo/mmmmmmmmkg/100mType 455.3 Class116126/0.402.2120/0.301.44.239.422425209/0.402.2120/0.301.44.543.328135285/0.402.2120/0.301.44.846.733650380/0.402.4183/0.301.45.351.942470203/0.672.454/0.671.45.757.055695259/0.672.470/0.671.66.160.5646120336/0.672.484/0.671.66.465.6786150427/0.672.4112/0.671.66.569.7931185518/0.672.4132/0.671.66.674./0.672.4168/0.671.66.880./0.672.4228/0.671.66.986.31600Type 455.6 Class116126/0.403.0120/0.301.44.743.926625209/0.403.0120/0.301.65.047.833235285/0.403.0120/0.301.65.351.338750380/0.403.0183/0.301.65.655.146670203/0.673.054/0.671.66.060.359795259/0.673.070/0.671.86.363.5692120336/0.673.084/0.671.86.568.5826150427/0.673.0112/0.671.86.672.6977185518/0.673.0132/0.671.86.777./0.673.0168/0.671.86.983./0.673.0228/0.671.87.089.11652Type 455.11 Class116126/0.405.0120/0.302.05.855.139225209/0.405.0120/0.302.06.159.046235285/0.405.0120/0.302.06.362.252750380/0.405.0183/0.302.06.465.660770203/0.675.054/0.672.06.570.274295259/0.675.070/0.672.26.773.2837120336/0.675.084/0.672.26.877.9982150427/0.675.0112/0.672.26.982./0.675.0132/0.672.27.086./0.675.0168/0.672.27.292.81553Type 455.22 Class116126/0.407.6120/0.302.56.668.557825209/0.407.6120/0.302.56.671.765335285/0.407.6120/0.302.56.774.771950380/0.407.6183/0.302.56.878.281070203/0.677.654/0.672.57.082.995695259/0.677.670/0.672.57.185./0.677.684/0.672.57.290./0.677.6112/0.672.57.394./0.677.6132/0.672.57.499.31564Type 455.33 Class116126/0.4010.5120/0.302.57.083.082225209/0.4010.5120/0.302.57.186.492035285/0.4010.5120/0.302.57.289.499350380/0.4010.5183/0.302.57.392.8109270203/0.6710.554/0.672.57.497.4125495259/0.6710.570/0.672.57.6100./0.6710.584/0.672.57.7105./0.6710.5112/0.672.57.8109.21720
Other supplier products
|
|
|
450/750V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (Multicore) CU/XLPE/CUTO/PVC 450/750V Class 2Application:The cables are mainl... |
|
|
|
XLPE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Single Pair)RE-2X(St)H 90°C / 300VSTANDARDSBasic design to EN 502... |
|
|
|
S13 BU(i) 250 V Individual Shielding fire resistant NEK606 Instrument cableApplications :These cables are fire resistant,Website:, flame retardant,... |
|
|
|
S1 or S1/S5 RFOU(i) 250V Individual Shielding &Armour NEK606 Instrument cableApplications :These cables are flame retardant,Website:, low smoke, ha... |
|
|
|
NTSKCGERLOEU Medium-Voltage Coal Cutter Cable VDE 0250 Part 813ApplicationsThese cables are used for the connection of mobile electrical equipment ... |