Type 455 3.3 To 33KV To AS/NZS 2802

Type 455 3.3 to 33KV to AS/NZS 2802ApplicationsThese cables are designed with reduced insulation and sheath thickness,Website:, no cradle, 2 earth and 1 pilotcore (each earth and pilot are the same size) in the outer interstices. These cablesare suitable for reeling and trailingapplications where minimal diameter and mass is desired, particularly suited to stacker-reclaimer applications.StandardsAS/NZS 2802:2000AS/NZS 1125AS/NZS 3808AS/NZS 5000.1Construction3×ConductorsFlexible stranded tinned annealed copper conductor.Conductor ScreenSemiconductive compound (for cables having a voltage rating of 3.3/3.3kV and above).InsulationEPR.Insulation ScreenSemiconductive elastomer.FillerElastomer centre filler.2×Interstitial Earth ConductorCSP insulated flexible stranded tinned copper conductor.1×Interstitial PilotEPR covered flexible stranded tinned copper conductor.Textile ReinforcementOpen-weave braid reinforcement.SheathExtra-heavy duty PCP sheath.Extra-heavy duty CPE/CSP sheath can be offered upon request.Dimensions and WeightNominal Conductor AreaStrand SizeInsulation ThicknessPilot/Earth ConductorThickness of SheathNominal Overall DiameterNominal WeightStrand SizeThickness of Coveringmm2No/mmmmNo/mmmmmmmmkg/100mType 455.3 Class116126/0.402.2120/0.301.44.239.422425209/0.402.2120/0.301.44.543.328135285/0.402.2120/0.301.44.846.733650380/0.402.4183/0.301.45.351.942470203/0.672.454/0.671.45.757.055695259/0.672.470/0.671.66.160.5646120336/0.672.484/0.671.66.465.6786150427/0.672.4112/0.671.66.569.7931185518/0.672.4132/0.671.66.674./0.672.4168/0.671.66.880./0.672.4228/0.671.66.986.31600Type 455.6 Class116126/0.403.0120/0.301.44.743.926625209/0.403.0120/0.301.65.047.833235285/0.403.0120/0.301.65.351.338750380/0.403.0183/0.301.65.655.146670203/0.673.054/0.671.66.060.359795259/0.673.070/0.671.86.363.5692120336/0.673.084/0.671.86.568.5826150427/0.673.0112/0.671.86.672.6977185518/0.673.0132/0.671.86.777./0.673.0168/0.671.86.983./0.673.0228/0.671.87.089.11652Type 455.11 Class116126/0.405.0120/0.302.05.855.139225209/0.405.0120/0.302.06.159.046235285/0.405.0120/0.302.06.362.252750380/0.405.0183/0.302.06.465.660770203/0.675.054/0.672.06.570.274295259/0.675.070/0.672.26.773.2837120336/0.675.084/0.672.26.877.9982150427/0.675.0112/0.672.26.982./0.675.0132/0.672.27.086./0.675.0168/0.672.27.292.81553Type 455.22 Class116126/0.407.6120/0.302.56.668.557825209/0.407.6120/0.302.56.671.765335285/0.407.6120/0.302.56.774.771950380/0.407.6183/0.302.56.878.281070203/0.677.654/0.672.57.082.995695259/0.677.670/0.672.57.185./0.677.684/0.672.57.290./0.677.6112/0.672.57.394./0.677.6132/0.672.57.499.31564Type 455.33 Class116126/0.4010.5120/0.302.57.083.082225209/0.4010.5120/0.302.57.186.492035285/0.4010.5120/0.302.57.289.499350380/0.4010.5183/0.302.57.392.8109270203/0.6710.554/0.672.57.497.4125495259/0.6710.570/0.672.57.6100./0.6710.584/0.672.57.7105./0.6710.5112/0.672.57.8109.21720
Other supplier products
|
|
|
450/750V SR Insulated fire resistant control cables (2-5 cores)(PH60) (CU/SR/LSZH 450/750V Class 2)Application:The cables are designed,Website:, ma... |
|
|
|
150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Individually Screened Unarmoured Flame Retardant Instrumentation & Control CablesApplication:... |
|
|
|
0.6/1 kV HEPR Insulated,Website:, LSOH (SHF1) Sheathed Flame Retardant Power & Control Cables (Multicore)ApplicationThese cables are used for fixed... |
|
|
|
German Standard Industrial Cables LiFY Application and DescriptionLiFY is highly flexible lead wire,Website:, it can be used as super flexible insu... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9830ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |