150/250V XLPE Insulated, LSOH (SHF1) Sheathed, Overall Screened Flame Retardant Instrumentation Control Cables (Multipair/Multitriple)
150/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Overall Screened Flame Retardant Instrumentation & Control Cables (Multipair/Multitriple)ApplicationThese cables are used on board of ships at all locations for fixed installations not subject to mechanical risk complying with IEC standards 60092-352. These cables are flame retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial vessels.StandardsIEC 60092-350/351/376/359IEC 60332-1IEC 60332-3-22IEC 60754-1/2IEC 61034ConstructionConductorsClass 2 stranded copper conductor.InsulationXLPE.Cabling ElementPair/Triple.Overall ScreenAl/polyester tape.Drain WireTinned copper wire.Outer SheathLSOH (SHF1). SHF2 can be offered upon request.Core IdentificationPair: White/blue with printed pair number and core number.Triple: White/blue/red with printed triple number.Mechanical and Thermal PropertiesBending Radius for Fixed Installations: 6×ODTemperature Range: -30℃ ~ +80℃Dimensions and WeightPart No.ConstructionNo. of elements×No. of cores in element×Crosssection(mm²)Nominal Insulation Thickness mmNominal Sheath Thickness mmNominal OverallDiameter mmNominal Weight kg/kmM092-RE-2X(St)H-2P0.52×2×0.50.41.08.575M092-RE-2X(St)H-4P0.54×2×0.50.41.110.0110M092-RE-2X(St)H-7P0.57×2×0.50.41.112.0160M092-RE-2X(St)H-10P0.510×2×0.50.41.215.0225M092-RE-2X(St)H-14P0.514×2×0.50.41.316.5290M092-RE-2X(St)H-19P0.519×2×0.50.41.318.0370M092-RE-2X(St)H-24P0.524×2×0.50.41.420.5460M092-RE-2X(St)H-1P0.751×2×0.750.51.06.960M092-RE-2X(St)H-2P0.752×2×0.75*0.51.07.880M092-RE-2X(St)H-3P0.753×2×0.750.51.110.8130M092-RE-2X(St)H-4P0.754×2×0.750.51.211.7160M092-RE-2X(St)H-7P0.757×2×0.750.51.314.1240M092-RE-2X(St)H-8P0.758×2×0.750.51.315.0270M092-RE-2X(St)H-10P0.7510×2×0.750.51.416.9320M092-RE-2X(St)H-12P07.512×2×0.750.51.417.6360M092-RE-2X(St)H-14P0.7514×2×0.750.51.418.3410M092-RE-2X(St)H-16P0.7516×2×0.750.51.519.8470M092-RE-2X(St)H-19P0.7519×2×0.750.51.520.7530M092-RE-2X(St)H-24P0.7524×2×0.750.51.623.5670M092-RE-2X(St)H-30P0.7530×2×0.750.51.726.3820M092-RE-2X(St)H-32P0.7532×2×0.750.51.726.8860M092-RE-2X(St)H-37P0.7537×2×0.750.51.828.3990M092-RE-2X(St)H-1P1.01×2×1.00.51.07.370M092-RE-2X(St)H-2P1.02×2×1.0*0.51.08.3100M092-RE-2X(St)H-3P1.03×2×1.00.51.211.8160M092-RE-2X(St)H-4P1.04×2×1.00.51.212.5190M092-RE-2X(St)H-7P1.07×2×1.00.51.315.1290M092-RE-2X(St)H-8P1.08×2×1.00.51.316.1320M092-RE-2X(St)H-10P1.010×2×1.00.51.418.2390M092-RE-2X(St)H-12P1.012×2×1.00.51.418.9450M092-RE-2X(St)H-14P1.014×2×1.00.51.519.8510M092-RE-2X(St)H-16P1.016×2×1.00.51.521.3570M092-RE-2X(St)H-19P1.019×2×1.00.51.622.4670M092-RE-2X(St)H-24P1.024×2×1.00.51.725.5830M092-RE-2X(St)H-30P1.030×2×1.00.51.828.61030M092-RE-2X(St)H-32P1.032×2×1.00.51.829.11080M092-RE-2X(St)H-37P1.037×2×1.00.51.930.71230M092-RE-2X(St)H-1P1.51×2×1.50.61.08.390M092-RE-2X(St)H-2P1.52×2×1.5*0.61.19.7140M092-RE-2X(St)H-3P1.53×2×1.50.61.213.6210M092-RE-2X(St)H-4P1.54×2×1.50.61.314.7260M092-RE-2X(St)H-7P1.57×2×1.50.61.417.8400M092-RE-2X(St)H-8P1.58×2×1.50.61.419.0450M092-RE-2X(St)H-10P1.510×2×1.50.61.521.5540M092-RE-2X(St)H-12P1.512×2×1.50.61.622.6630M092-RE-2X(St)H-14P1.514×2×1.50.61.623.4710M092-RE-2X(St)H-16P1.516×2×1.50.61.725.4820M092-RE-2X(St)H-19P1.519×2×1.50.61.726.5930M092-RE-2X(St)H-24P1.524×2×1.50.61.930.41180M092-RE-2X(St)H-30P1.530×2×1.50.62.034.11460M092-RE-2X(St)H-32P1.532×2×1.50.62.034.71540M092-RE-2X(St)H-37P1.537×2×1.50.62.136.61760M092-RE-2X(St)H-1T0.751×3×0.750.51.07.270M092-RE-2X(St)H-2T0.752×3×0.750.51.111.0130M092-RE-2X(St)H-3T0.753×3×0.750.51.211.8170M092-RE-2X(St)H-4T0.754×3×0.750.51.212.9210M092-RE-2X(St)H-7T0.757×3×0.750.51.316.2330M092-RE-2X(St)H-8T0.758×3×0.750.51.417.5380M092-RE-2X(St)H-10T0.7510×3×0.750.51.519.9460M092-RE-2X(St)H-12T07.512×3×0.750.51.520.9520M092-RE-2X(St)H-14T0.7514×3×0.750.51.521.8590M092-RE-2X(St)H-16T0.7516×3×0.750.51.623.3670M092-RE-2X(St)H-19T0.7519×3×0.750.51.725.3790M092-RE-2X(St)H-24T0.7524×3×0.750.51.828.1980M092-RE-2X(St)H-30T0.7530×3×0.750.51.931.11200M092-RE-2X(St)H-32T0.7532×3×0.750.51.932.21270M092-RE-2X(St)H-37T0.7537×3×0.750.52.033.91450M092-RE-2X(St)H-1T1.01×3×1.00.51.07.780M092-RE-2X(St)H-2T1.02×3×1.00.51.212.1160M092-RE-2X(St)H-3T1.03×3×1.00.51.212.8200M092-RE-2X(St)H-4T1.04×3×1.00.51.314.2260M092-RE-2X(St)H-7T1.07×3×1.00.51.417.8410M092-RE-2X(St)H-8T1.08×3×1.00.51.419.0460M092-RE-2X(St)H-10T1.010×3×1.00.51.521.6560M092-RE-2X(St)H-12T1.012×3×1.00.51.623.0660M092-RE-2X(St)H-14T1.014×3×1.00.51.624.0740M092-RE-2X(St)H-16T1.016×3×1.00.51.725.6840M092-RE-2X(St)H-19T1.019×3×1.00.51.827.8990M092-RE-2X(St)H-24T1.024×3×1.00.51.930.81230M092-RE-2X(St)H-30T1.030×3×1.00.52.034.21510M092-RE-2X(St)H-32T1.032×3×1.00.52.035.41600M092-RE-2X(St)H-37T1.037×3×1.00.52.137.31830M092-RE-2X(St)H-1T1.51×3×1.50.61.18.9110M092-RE-2X(St)H-2T1.52×3×1.50.61.213.8210M092-RE-2X(St)H-3T1.53×3×1.50.61.314.9280M092-RE-2X(St)H-4T1.54×3×1.50.61.316.3350M092-RE-2X(St)H-7T1.57×3×1.50.61.520.8570M092-RE-2X(St)H-8T1.58×3×1.50.61.622.4660M092-RE-2X(St)H-10T1.510×3×1.50.61.725.5790M092-RE-2X(St)H-12T1.512×3×1.50.61.726.9920M092-RE-2X(St)H-14T1.514×3×1.50.61.828.31050M092-RE-2X(St)H-16T1.516×3×1.50.61.830.01180M092-RE-2X(St)H-19T1.519×3×1.50.61.932.51390M092-RE-2X(St)H-24T1.524×3×1.50.62.136.31740M092-RE-2X(St)H-30T1.530×3×1.50.62.240.32150M092-RE-2X(St)H-32T1.532×3×1.50.62.341.92300M092-RE-2X(St)H-37T1.537×3×1.50.62.444.12620
Other supplier products
|
|
Multipair Individually Screened Cables-Belden Equivalent 9732ApplicationsThese cables have individually screened pairs laid up. Each individually s... |
|
|
PE Insulated,Website:, LSZH Sheathed, Individual and Overall Screened Instrumentation Cables (Multipair)RE-2Y(St)H Pimf 90°C / 300VSTANDARDSBasic d... |
|
|
P18 RU 0.6/1kV NEK606 CableApplications :These cables are flame retardant,Website:, low smoke, halogen free and mud resistant, used for control, po... |
|
|
600/1000V LSZH Insulated (single core) Application:The cables are mainly used in power stations,Website:, mass transit underground passenger system... |
|
|
(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber OpticsApplicationsThese cables are used for For laying alongside the conveyor belts... |
供应产品
Same products