Harmonized Code Industrial Cables H05VV5-F(NYSLYÖ-JZ)

Harmonized Code Industrial Cables H05VV5-F(NYSLYÖ-JZ)Application and DescriptionThese cables are suitable for dry,Website:, damp and wet locations but not in tde open-air. They are used as screened termination and connection cable in tde control, measuring and signal technology. The copper braiding optimises protection against external interferences, like electromagnetic fields and stray frequencies. Suitable as a signal and impulse cable for control and inspection of industrial plants, machinery and working processes.Standard and ApprovalHD 21.13 S1VDE-0281 Part-13CEI 20-20/13CEI 20-35 (EN60332-1)CEI 20-52UL 2464Cable Construction1 Fine bare copper strandsStrands to VDE-0295 Class-5, IEC 60228 Class-52 PVC insulation T12 to DIN VDE 0281 part 1Green-yellow grounding (3 conductors and above)Cores to VDE-0293 colors3 PVC sheatd TM5 to DIN VDE 0281 part 1Technical CharacteristicsWORKING VOLTAGE: 300/500vTEST VOLTAGE: 2000voltsFLEXING BENDING RADIUS: 7.5 x ØSTATIC BENDING RADIUS: 4 x ØFLEXING TEMPERATURE: -5 ºC to +70 ºCSTATIC TEMPERATURE: -40 ºC to +70 ºCSHORT CIRCUIT TEMPERATURE: +150 ºCFLAME RETARDANT: IEC 60332.1INSULATION RESISTANCE: 20 MΩ x kmCable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREANOMINAL THICKNESS OF INSULATIONNOMINAL THICKNESS OF SHEATHNOMINAL OVERALL DIAMETERNOMINAL COPPER WEIGHTNOMINAL WEIGHT# X MM²MMMMMMKG/KMKG/KM20(16/32)2x0.500.60.75.69.74618(24/32)2x0.750.60.86.214.45217(32/32)2x10.60.86.619.26616(30/30)2x1.50.70.87.6297714(50/30)2x2.50.80.99./32)3x0.500.60.75.914.45418(24/32)3x0.750.60.86.621.66817(32/32)3x10.60./30)3x1.50.70.98.2439714(50/30)3x2.50./32)4x0.500.60.86.6196518(24/32)4x0.750.60.87.228.88217(32/32)4x10.60.87.838.410416(30/30)4x1.50.70.99./30)4x2.50.81.110./32)5x0.500.60.87.3248018(24/32)5x0.750.60./32)5x10.60.98./30)5x1.50.7110./30)5x2.50.81.112./32)6x0.500.60.98.128.810418(24/32)6x0.750.60.98.743.213217(32/32)6x10.619./30)6x1.50.71.111./30)6x2.50.81.213./32)7x0.500.60.98.133.611918(24/32)7x0.750.618.950.514517(32/32)7x10.619./30)7x1.50.71.211./30)7x2.51.30.813./32)12x0.500.61.110./32)12x0.750.61.111./32)12x10.61.212./30)12x1.50.71./30)12x2.51.50.817./32)18x0.500.61.212./32)18x0.750.61.314./32)18x10.61.315./30)18x1.50.71./30)18x2.51.80.821./32)25x0.500.61.415./32)25x0.750.61.516./32)25x10.61./30)25x1.50.71.821./30)25x2.50.82.125./32)36x0.500.61.517./32)36x0.750.61.619./32)36x10.61.720./30)36x1.50./30)36x2.50.82.329./32)50x0.500.61.721./32)50x0.750.61.823./32)50x10.61.924./30)50x1.50.7228./30)50x2.50.82./32)61x0.500.61.823./32)61x0.750.6225./32)61x10.62./30)61x1.50.72.430./30)61x2.50.82.437.114642724
Other supplier products
|
|
|
50/250V XLPE Insulated,Website:, LSOH (SHF1) Sheathed, Armoured Flame Retardant Instrumentation & Control Cables (Multicore)ApplicationThese armour... |
|
|
|
Belden8355
Website: |
|
|
|
VDE Standard Industrial Cables H03V2V2-F/H03V2V2H2-F Application and DescriptionThese cables are suitable for domestic premises,Website:, kitchen, ... |
|
|
|
Type 441 (class 1) 3.3 to 22KV to AS/NZS 2802ApplicationsType 441 Class 1 series cable has lower insulation and sheath radials than Class 2 cables,... |
|
|
|
450/750V PVC Insulated,Website:, Non-sheathed Power Cables (Single Core) CU/PVC 450/750V Class 2Application:The cables are mainly used in power sta... |
供应产品
Same products