High reliability walk-in heat aging chamber
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Applications
Walk-in High-Temperature Aging Chambers are typically assembled on-site using insulated panels (double-sided color steel sheets with insulation material in between). Chamber dimensions are customized to client specifications. The complete walk-in high/low temperature and humidity test chamber features comprehensive safety protection devices and provides troubleshooting methods, with safety ratings surpassing other brands. Protection Devices: Fuse-less switches, fuses, over-temperature protection, dry-run protection, low-water protection, liquid level protection, compressor overpressure, overheat, and overcurrent protection. Comprehensive protection includes compressor overload/overheat protection, phase loss protection, and a fault alarm system.
Standards
GJB150.3 (ML-STD-810D) High Temperature Test Method
GJB150.4 (MIL-STD-810D) Low Temperature Test Method
GJB360.8-87 (MIL-STD-202f) High Temperature Life Test
GB/T5170.2-96 Temperature Test Equipment
GB2423.1-89 (IEC68-2-1) Basic Environmental Test Procedures for Electrical and Electronic Products Test A: Low Temperature Test Method
GB2423.2-89 (IEC68-2-2) Basic Environmental Test Procedures for Electrical and Electronic Products - Test B: High Temperature Test Method
GB5170. 2. 3. 5. 6-95 “Calibration Methods for Basic Parameters of Environmental Test Equipment for Electrical and Electronic Products - Low Temperature, High Temperature, Constant Humidity and Heat, Alternating Humidity and Heat Test Equipment” Requirements
Features
1. Simple maintenance and user-friendly operation are key advantages of our products.
2. The independent frame design ensures the refrigeration system and air distribution system operate separately.
3. Maintenance and repairs can be performed during unit operation, resulting in low annual failure rates and simplified, rapid servicing.
Parameters
| Item | Specifications |
|---|---|
| Dimensions | 200 cm (W) × 200 cm (H) × 200 cm (D); customizable per customer requirements, with external dimensions subject to actual size |
| Temperature Range | Optional ranges: 0°C~20°C / -40°C~60°C / -70°C~+85°C / 100°C (lower temperature ranges are higher in cost; choose based on product needs) |
| Temperature Fluctuation | ±0.5°C (defined as half the difference between the highest and lowest measured temperatures at the center point) |
| Temperature Uniformity | ±2.0°C (defined as the arithmetic mean of the differences between highest and lowest measured temperatures per test) |
| Heating Time | From room temperature (+10°C) to +85°C: <60 minutes, non-linear no-load heating rate ≈3°C/min |
| Cooling Time | - From +10°C to 0°C: <30 minutes, non-linear no-load cooling rate ≈1°C/min- From +10°C to -20°C: <45 minutes, non-linear no-load cooling rate ≈1°C/min- From +10°C to -40°C: <60 minutes, non-linear no-load cooling rate ≈1°C/min |
| Operating Noise | A-weighted sound level ≤60 dB(A), measured in anechoic chamber at 25°C ambient temperature, using A-weighting, averaged over 8 test points (each at 1m from noise source and 1m above ground) |
Test Procedures
1. Pre-Operation Preparation
Train personnel on safety procedures, emergency stop methods, and chamber operation.
Verify grounding and electrical system integrity; ensure voltage is within specifications (~380V).
Ensure adequate ventilation and unobstructed exhaust system.
Wear appropriate personal protective equipment (PPE) including heat-resistant gloves, safety shoes, and protective eyewear.
2. Sample Placement
Arrange test samples to avoid overcrowding and ensure uniform airflow.
Ensure sample weight and volume do not exceed chamber limits.
3. Operation
Set desired temperature and duration according to test protocol.
Start the chamber and monitor temperature via PID control system.
Check for abnormal readings or fluctuations; adjust settings as necessary.
4. Monitoring During Test
Continuously monitor internal temperature and airflow.
Inspect for leaks or abnormal fumes if using gas or electric heating.
Restrict access to authorized personnel only.
在线联系供应商
Other supplier products
| Vacuum Leak Detection Equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications 1. Automotive Industry In automobile manufacturing, sealing performance is d... | |
| Sharp edge tester | Standards : ASTM F963 4.8. EN71-1998 8.14. GB6675-2003 A.5.9. 16CFR 1500.48 Basic Configuration: Sharp Edge Tester: 1 unit Foot switch: 1 set ... | |
| Abrasive Wear Test Apparatus | Standard ASTM G65 - 04 GB/T 3960-1983 Main Purposes The wet - type rubber wheel abrasive wear testing machine is primarily employed to assess t... | |
| Aerosol Sensor Test System,Aerosol and Dust Monitors Test System | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Aerosol Sensor Test System is designed for development, testing, and calibration of act... | |
| Cabin Air Filter Test System(Gas Adsorption) | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Evaluating gas adsorption and desorption performance of cabin air filter eleme... |
Same products
| Walk-in Environmental Constant Temperature and Humidity Test Chamber | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T2423.3 Environmental Testi... | |
| High reliability walk-in heat aging chamber | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Walk-in High-Temperature Ag... | |
| Fully programmable walk-in climate simulation system | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications High and Low Temperature Hu... | |
| PV Degradation Testing Chamber | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Light Decay Test Chambe... | |
| PV module acid corrosion test equipment supplier | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Photovoltaic Acid Mist ... |