Fast thermal conductivity tester
Fast thermal conductivity tester-Mainly used for the determination of non-metallic solid material thermal conductivity, suitable for testing units, universities, research and production units to use.
Standards compliant:
GB 10297-1998, GB / T10294-2008, GB / T10801.1, GB / T10801.2
GB 10297-1998, GB / T10294-2008, GB / T10801.1, GB / T10801.2
TheFast thermal conductivity testermain parameters:
1. Power supply: AC220V ± 10%, 50Hz
2. Temperature range: (0-80) ℃
3. Temperature resolution: 0.01 ℃
4. Temperature measurement accuracy: 0.1 ℃
5. Thermal conductivity measurement range: ≤ 2W / (m · K)
6. Measurement error: ± 5%
7. Maximum measurement time: 300s
8. Laboratory temperature: (23 ± 2) ° C
9. Laboratory humidity: (40-60%) RH
2. Temperature range: (0-80) ℃
3. Temperature resolution: 0.01 ℃
4. Temperature measurement accuracy: 0.1 ℃
5. Thermal conductivity measurement range: ≤ 2W / (m · K)
6. Measurement error: ± 5%
7. Maximum measurement time: 300s
8. Laboratory temperature: (23 ± 2) ° C
9. Laboratory humidity: (40-60%) RH
Fast thermal conductivity testerMain features:
1. Measurement time is short: the measurement process, the specimen material denatured, deformation is small, the measured value closer to the true value;
2. Easy to operate: all the use of microcomputer intelligent control, the operator without special training, you can directly post operation;
3. Wide test range: the basic effective coverage of non-metallic materials and low thermal conductivity of the metal material;
4. Widely used: widely used in construction, energy, environmental protection, chemical, medical, energy and other industries.
1. Measurement time is short: the measurement process, the specimen material denatured, deformation is small, the measured value closer to the true value;
2. Easy to operate: all the use of microcomputer intelligent control, the operator without special training, you can directly post operation;
3. Wide test range: the basic effective coverage of non-metallic materials and low thermal conductivity of the metal material;
4. Widely used: widely used in construction, energy, environmental protection, chemical, medical, energy and other industries.
在线联系供应商
Other supplier products
Fabric Hand Feel Tester | Brief Introduction:By softness value of the test material and objective evaluation of its feeling (touch) performance for softness test fabrics, te... | |
Moisture Management Tester | Standards: AATCC 195,SN 1689.1,GB/T 21655.2 Applications: The sportswear fabric testing, underwear apparel fabrics testing and research. Pr... | |
Rainproof performance tester of Fabric | Rainproof performance tester of Fabric can detect the water repellency of fabrics or composites under different rain pressure.Standards Compliant:A... | |
Curtain Flammability Tester | IntroductionThis tester mainly based on NFPA 701 R & D and the United States NFPA 701 that provides fabric and film flame propagation test meth... | |
Fabric Heat Conduction Performance Tester | TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi Portuguese Catalan Hmong Daw Romanian ... |
Same products
安泰信 ST-2065D ST-2080D ST-2150D 数字电烙铁 | 卖方: 深圳市维客修科技有限公司 | 描述 ATTEN ST-2065D ST-2080D ST-2150D 便携式电烙铁带LED数字显示,65W 80W 150W可选,80℃-480℃可调温度,适用于手机PCB、... | |
TBK-988X多功能旋转液晶加热分切机 | 卖方: 深圳市维客修科技有限公司 | 2024 TBK 988X加热分离机采用反向分离手机屏幕技术,避免损坏偏光片并保持屏幕完好。TBK 988X恒温加热平台与TBK002除胶剂配合使用,用于LCD OCA脱胶。TBK BK-002... | |
APF-4.0A-4KW with 1978-4540 volume 1120-668 pressure POPULA air purification box | 卖方: Popula Group Company 九洲普惠集团公司Limited | Puduct Name: APF-4.0A-4KW with 1978-4540 volume 1120-668 pressure POPULA air purification box ... | |
HTFC-I-30-III-15KW with volume 620-535pressure POPULA Fan Fire Cabinet Fan Single Speed Centrifugal Fan | 卖方: Popula Group Company 九洲普惠集团公司Limited | Puduct Name: HTFC-I-30-III-15KW with volume 620-535pressure POPULA Fan Fire Cabinet Fan Singl... | |
JQZ-4.5A-5.5KW-2P with 1169-3542 CMH volume 3378-1856 pressure POPULA Broken Edge Paper Centrifugal Fan High Pressure | 卖方: Popula Group Company 九洲普惠集团公司Limited | Puduct Name: JQZ-4.5A-5.5KW-2P with 1169-3542 CMH volume 3378-1856 pressure POPULA Broken Edge P... |