Plastic Smoke Density Tester
Introduction
The main principle of smoke density measurement is that in a particular space, the cable or material produces smoke under specific combustion or radiation conditions, and the light beam penetrating through the smoke will produce attenuation. Measuring the light transmittance and calculation will get the optical density and smoke density.
The instrument is designed and developed according to ISO5659 related standards. With the use of Conical radiation furnace, the heat flux in the chamber can be as high as 50 kW/ m2, and the sample can be positioned horizontally to test the mass loss rate of the sample. This also complies with the latest IMO test terms. Measure the amount of smoke generated when the sample is vertically exposed to a radioactive heat source at 25 kW / m2 when there is or there is no forward flame in confined space.
Using the standard ISO 5659 conical radiant heating furnace, the user can adjust the heating conditions from 10 kW㎡ into 50 kW/㎡ or 70kW/㎡.
Standards
GB/T8323.2-2008: Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test
ISO 5659-1: Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test
ISO 5659-2: Plastics-Smoke generation-Part2: Determination of optical density by a single-chamber test
·The tester consists of a chamber, a sample box, a radiant cone, an igniter, a light transmission and measuring device and other related control devices.
·Ergonomic design and control design; chamber with a fully open door ; door lock designed to facilitate one-time closure of the door; optimize the operation process.
·The test chamber door can be fully opened to facilitate loading and unloading samples and cleaning the box;
·Front door, hinge mounted, with window and non-transparent light shading board which can block the window, to prevent light from entering the sealed chamber.
·The controller is located on the side of the chamber for easy operation. When the door is closed, it does not affect the controller to be viewed.
·Safe flameout board, easy to replace, more secure operation.
·A gas measuring port is available for testing gas toxicity.
·The coating of the test chamber is easy to clean and resistant to chemical corrosion.
Combustion Apparatus
·Heating cone: power 2600W, input temperature range of 0 ~ 1000℃, stable within ± 2℃ within 50 mins, can provide 10KW / m²-50KW / m² of radiation exposure.
·The use of mass flow controllers and differential pressure sensors enhances the accuracy of the manometer and enables automatic leak testing.
·The ignitor is equipped with automatic ignition device; flame length 30mm ± 5mm; in accordance with the standard provisions of blue flame with yellow on the top.
·Smoke density and temperature are digital displayed, more simple view, more accurate value
·Photoelectric detection components include photomultiplier tubes, amplifying filters, optical shutters, optical filters, neutral optical filters, lenses, optical windows, etc.
·The light source is 6.5V incandescent lamp.
·An optical cartridge is installed on the top of the chamber. the light source is receipted by the side window type photoelectric multiplier. Light transmittance accuracy can reach 0.001%
·Achromatic lens
·Silicon photovoltaic cells
·High gain and low noise amplifier control circuit
Smoke Density Measurement System
·Smoke density and temperature are digital displayed, more simple view, more accurate value
·Photoelectric detection components include photomultiplier tubes, amplifying filters, optical shutters, optical filters, neutral optical filters, lenses, optical windows, etc.
·The light source is 6.5V incandescent lamp.
·An optical cartridge is installed on the top of the chamber. the light source is receipted by the side window type photoelectric multiplier. Light transmittance accuracy can reach 0.001%
·Achromatic lens
·Silicon photovoltaic cells
·High gain and low noise amplifier control circuit
·Automatic completion of the test; a variety of signals automatically collected
·Branded computer
Control System
·Automatic completion of the test; a variety of signals automatically collected
·Branded computer
·The printer is optional
·Voltage: 220V; Power 4KW
·Propane gas customer-owned
Other supplier products
|
LOI Limiting Oxygen Index Test Chamber for combustible materials |
While many designs of the LOI test apparatus calculate oxygen index based on the flow of oxygen and nitrogen, the unit incorporates a paramagnetic ... |
|
Chrysler LP-463LB low-temperature Bending Test Machine |
The Chrysler Flex Fold Tester was designed for the determination of the mechanical stability of anchorage of the coating materials to the backing f... |
|
医用口罩的综合血透仪 |
该将在规定的测试条件下测试医用口罩对的抵抗力。
合成血液渗透测试仪的特点:
1.口罩固定装置是金属人头模具,可以完全模拟口罩的实际使用状态。
2.金属人头模具可以旋转一定角度,方便样品夹持。
3.特殊设计的注射控制装置,可以在控制时间内喷出一定量的合成血。
4.仪器使用可提供(700... |
|
Drill Flocking Performance Tester |
Drill Flocking Performance Tester
Testing Standards:
GB/T 12705.1/14272, BS EN 12132-1
Applications:
Drill Flocking Performance Tester is designe... |
|
Footwear Bending Tester |
Footwear Flection Tester
Standards:
Satra TM92 & 77
Applications:
The Footwear Flection Tester is designed to assess the flexing endurance of... |
供应产品
Same products