Gas engine filter tester

Product Introduction:

The gas engine filter is an efficient filtration equipment used to filter and exclude impurities in the medium in the pipeline during the pipeline transportation process, and is a special device designed for the transmission of oxygen production pipe network, usually installed in the pressure reducing valve, pressure relief valve, fixed level valve or other equipment at the inlet end to eliminate impurities in the medium to protect the normal and safe use of valves and equipment.

The gas engine filter is composed of a shunt cone and a filter tube to purify the medium in the pipeline, improve the quality of natural gas, and prevent accidents caused by poor quality of natural gas. At present, it has been widely used in petroleum, chemical, pharmaceutical, food, environmental protection and other industries.

Standards:

ISO 4548. ISO 5011. SAE J905. GB/T 28949. GB/T 14295

Applications:

1. Weakly corrosive materials in petrochemical gas production: water, oil, ammonia, hydrocarbons, etc.

2. Corrosive materials in chemical production: caustic soda, soda ash, concentrated sulfuric acid, carbonic acid, acetic acid, ester acid, etc.

3. low temperature materials in industrial production: liquid methane, liquid ammonia, liquid oxygen and various refrigeration.

4. food, pharmaceutical production of hygiene requirements of the material: beer, beverages, dairy products, food pulp and medical supplies.

Operation and maintenance:

1. the first installation should be cleaned after a period of time to remove impurities and other dirt accumulated on the filter screen during the initial operation of the system.

2. the natural gas filter must be regularly checked and cleaned during use, and the frequency is determined according to the actual working conditions. When the filter works for a period of time, some impurities will precipitate inside the filter element, so that the pressure increases and the flow rate decreases, which needs to be removed in time.

3. when cleaning impurities, pay special attention to protect the stainless steel wire mesh layer covered by the surface of the filter element, can not be deformed or damaged; If the wire mesh layer is found to be deformed or damaged, it needs to be replaced immediately.

4. If the filter does not have a drain plug, the filter stopper and filter screen should be removed during cleaning.

5. Before each maintenance and cleaning, the filter should be isolated from the pressure system. After cleaning, use a new gasket when reinstalling.

Technical parameters

1. Test air volume: 3-30 m³/h, can be customized.

2. Test gases: HzS, SO2. NH3. C Hg, etc.

3. Test area: <20x20cm.

4.Pressure range: 0-500 Pa, 0~1000 Pa, 0-3000 Pa, you can choose one.

5. Test period: can be set freely, minimum >5s.

6. Gas analyzer: according to test gas, PlD, electrochemical, infrared, etc. For Toluene: measuring range

100ppm, accuracy+ 2% F'S, resolution 0.01ppm.

7. Accuracy of pressure gauge: 1%.

8. Dimensions (L*W*H):750x800x1750mm (Excluding gas cylinder and fan).

9. Power supply: AC220V, 50Hz,2000W.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

 Automotive Wires Ozone Aging Chamber-QINSUN
Automotive Wires Ozone Aging Chamber-QINSUN Standards ISO 6722: Road vehicles – Electrical cables – Dimensions and test methods. SAE J1128: Low-voltage cables for automotive a...
ISO 12103-2 M2 Test Dust
ISO 12103-2 M2 Test Dust Product Introduction: Particle Technology Fuel Contamination Test Dust offers a full range of fuel contamination test materials used to test the...
Automotive Wire Adhesion Tester
Automotive Wire Adhesion Tester Standard Engineered to meet the rigorous demands of global automotive and adhesives industries, our Automotive Wire Adhesion Tester strictly adh...
Industrial chillers
Industrial chillers Applicable Standards Industrial chillers adhere to global safety and performance regulations, including: ASHRAE 15(Safety Standard for Refrig...
Fabric Anti-Electromagnetic Radiation Performance Tester
Fabric Anti-Electromagnetic Radiation Performance Tester Standards GB/T23326. GB/T25471. ASTM D4935. SJ2054 Application It is used for testing the electromagnetic shielding effectiveness of electromagn...
供应产品

Same products

Common Rail Injector Valve F00R J02 012
Common Rail Injector Valve F00R J02 012 卖方: 868983 Common Rail Injector Valve F00R J02 012 David Chen
Common Rail Injector Valve F00R J02 005
Common Rail Injector Valve F00R J02 005 卖方: 868983 Common Rail Injector Valve F00R J02 005 David Chen
Common Rail Injector Valve F00R J01 945
Common Rail Injector Valve F00R J01 945 卖方: 868983 Common Rail Injector Valve F00R J01 945 David Chen
Common Rail Injector Valve F00R J01 941
Common Rail Injector Valve F00R J01 941 卖方: 868983 Common Rail Injector Valve F00R J01 941 David Chen
Common Rail Injector Valve F00R J01 924
Common Rail Injector Valve F00R J01 924 卖方: 868983 Common Rail Injector Valve F00R J01 924 David Chen