.

High-precision Material Thermal Conductivity Tester

Get a quote:

Whats/App: +86 185 0176 3615

Web: qinsun-lab.com

Email: serving@qinsun-lab。com

It adopts the internationally popular method of heat flow meter to detect thermal conductivity and thermal resistance, and realizes fully automatic detection with computer and generates experimental report. The instrument adopts to add stable hot surface temperature on one side of the specimen, the heat is transferred to the cold surface through the specimen, and the transferred heat flow is measured to calculate the thermal conductivity and thermal resistance. Adopting imported sensors and computer technology, the instrument is characterized by good measurement accuracy, high reliability and good repeatabilitygood characteristics. Especially suitable for low thermal conductivity measurement (accurate to 0.1mw). It can be used for testing plastics, rubber, thermal insulation materials, aerogel panels, vacuum glass, etc. It is widely used in colleges and universities, scientific research institutes, quality inspection, factories and mines.

Reference standard

ASTME1530.ASTM C518-04 Test method for determining steady-state heat flux and heat transfer characteristics by the thermofluid meter method

Packing list

1.One host computer;

2. Aset of analysis software (Chinese and English version);

3.HX-1005 precision low-temperature constant temperature water tank a (temperature control accuracy 0.01 ℃);

5. Standard sample*1pcs;

Dimension

1.Host: Standard floor model: (L×W×H) 550×450×1500mm, net weight: 100Kg.

2.Precision low-temperature constant temperature water tank: (L×W×H) 300×350×530mm, net weight: 35Kg.

Technical Parameter

1.The range of thermal conductivity: 0.0001 ~ 1W / mk, can be measured accurately to 0.1mw / mk.

0.001~300W/mk. computer automatically switch the range.

2.Measurement accuracy: 1%.

3.Sample size: 50 × 50 ~ 300 × 300 (mm) (standard configuration), the thickness is not greater than 50mm.

600 × 600. 800 × 600 (mm) and other special sizes can be customized.

4.Can test solid material, powder material.

5.Measuring time 15~20 min.

6.Hot surface temperature and control: room temperature ~ 99.9 ℃ (standard configuration), room temperature ~ 299.9 ℃, room temperature ~ 499.9 ℃. Plate heater, bi-directional SCR control, temperature control accuracy 0.1℃.

7. Cold surface temperature and control: 0 ~ 99.9 ℃ (standard configuration), -10 ~ 99.9 ℃, according to user requirements to determine the lower temperature.Cold surface temperature and control The cold surface is water-cooled to ensure the stability of the cold surface temperature (precision thermostatic water tank, temperature adjustable), temperature control accuracy of 0.1 ℃.

8. The specimen using computerized precise pressure clamping, pressure range 0 ~ 1000N, resolution 0.1N.

9.Automatic measurement of specimen thickness, 0~50mm, resolution 1um.

10.Imported original heat flow meter, stable and reliable performance.

11.The whole process adopts computerized automatic testing and printing andsaveexperimental data.


在线联系供应商

至: Standard Groups
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Microbial Barrier Tester | ASTM ISO Testing Machine
Microbial Barrier Tester | ASTM ISO Testing Machine Get a quote: Web: qinsun-lab.com Whats/App: +86 185 0176 3615 Y/T 0471.5-2017 is a newly updated standard, which specifies the experimental meth...
Reciprocating Wear Tester
Reciprocating Wear Tester Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com Reciprocating wear Tester - Characteristics evaluat...
Connector Air Tightness Tester
Connector Air Tightness Tester Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Connector Air Tightness Tester is a professional device used to evaluate the s...
Cone Calorimeter Heat Release Test Machine
Cone Calorimeter Heat Release Test Machine Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com Heat release quantity is the core parametersto eval...
Bundle wire and cable burning test machine
Bundle wire and cable burning test machine Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com Standards According to IEC60332-3-10:2000.and GA30...
供应产品

Same products

ER4043 Silicon Aluminum Welding Wire
ER4043 Silicon Aluminum Welding Wire 卖方: 868776 Hangzhou Kunli Welding Materials Co., Ltd. specializes in manufacturing high-quality welding mate...
Choosing the Right Equipment for Heavy-Duty Cleaning
Choosing the Right Equipment for Heavy-Duty Cleaning 卖方: Taizhou Feike Mechanical Technology Co., Ltd. FEIKE’s High Pressure Washer is designed for industrial cleaning, equipment maintenance, ve...
ER4043 Silicon Aluminum Welding Wire
ER4043 Silicon Aluminum Welding Wire 卖方: 868776 Hangzhou Kunli Welding Materials Co., Ltd. offers ER4043 Silicon Aluminum Welding Wire for alumin...
HDPE高速水冷双壁波纹管生产线
HDPE高速水冷双壁波纹管生产线 卖方: Shandong HUASU Plastic Technology Co.,Ltd. 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功...
PanEVAP & MVR system
PanEVAP & MVR system 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...