PV Light Induced Degradation (LID) Testing Chamber
The Light Decay Test Chamber is designed as an indoor exposure system, primarily used for standard module and cell degradation testing, module hot spot testing, and module pre-treatment. Spectral matching, irradiance uniformity, and irradiance stability meet at least BBB-grade standards.
This system comprises a light source system, temperature control system, module support structure, light source control system, and irradiance monitoring system. Utilizing xenon lamps as the light source, the irradiance across the exposure surface can be steplessly adjusted between 400 and 1200 W/m².
Standards
IEC 61215: Terrestrial photovoltaic (PV) modules—Design qualification and type approval (Specifically the Light-Induced Degradation and Hot-spot tests).
IEC 60904-9: Photovoltaic devices—Part 9: Classification of solar simulator characteristics (Meeting BBB or higher standards).
GB/T 9535: Ground-based silicon solar photovoltaic modules—Design qualification and type approval.
IEC 61646: Thin-film terrestrial photovoltaic (PV) modules—Design qualification and type approval (Stabilization phases).
Parameters
| Category | Item | Specifications |
|---|---|---|
| 1. Xenon Lamp Parameters | Dimensions | 200*40mm |
| Power | 1800W | |
| Operating Voltage | 180VAC | |
| Lamp Life | 700h (with cumulative timing function for lamp tube) | |
| 2. Chamber Structure | Construction | Welded integral structure |
| Outer Wall Material | Galvanized steel sheet (spray-painted) | |
| Inner Wall Material | SUS304 stainless steel sheet | |
| Insulation Material | Glass fiber or polyurethane foam material | |
| Accessories | Equipped with standard viewport: 1 multi-layer glass window (with work light) | |
| 3. Radiometer | Spectral Range | 300 ~ 3000nm |
| Irradiance Range | 0 ~ 2000W/m² | |
| Annual Stability | 2% | |
| Azimuth Response Error | 5% | |
| Non-linearity | 2% | |
| Temperature Error | 2% (-10°C ~ 40°C) | |
| 4. Temperature | Sensor Type | PT100 |
| Measurement Range | -200 ~ 500°C | |
| Test Accuracy | ±1°C | |
| Resolution | 0.1°C | |
| Probe Diameter | Φ5mm | |
| Installation Method | Fixed with movable screws | |
| Probe Length | 5cm | |
| Resistance Change | 0.3851Ω/°C | |
| Lead Connection Method | Three-wire type | |
| Sleeve Material | Stainless steel 304 |
在线联系供应商
Other supplier products
| UV Lamp Aging Test Tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com This product uses fluorescent UV lamps, combined wi... | |
| Computer-controlled Explosion-proof Capillary Rheometer | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Computer-controlled Explosion-proof Capillary Rheometer is a laboratory rheolo... | |
| Adjustable Angle Shoes Flexing Tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The finished shoes will be installed on the finished shoes flexing tester, and the... | |
| comparative tracking index tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com Comparative tracking index testeris suitable for th... | |
| Horizontal Vertical Combustion Tester | Horizontal and vertical combustion tester is mainly used for measuring the burning performance of plastic, rubber or film at a predetermined fire s... |
Same products
| Tabletop Xenon Arc Weathering Tester (SunMaster) | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Water-Cooled Xenon Lamp Weat... | |
| Blow-By Test Rig | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test system for the characterisa... | |
| Air filter System(ISO 16890/EN 779) | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Filter test system for general a... | |
| Oil Thread Leak Test System | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test System for oil thread leak ... | |
| Manual HEPA/ULPA Filter Scanning Test System | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Manual HEPA/ULPA Filter Scan... |