Battery Powder Compaction Density Measurement System,Battery Powder Compaction Density Characterization System

Whats/App: +86 156 1874 6768

Web: standard-groups.com

The Battery Powder Compaction Density Measurement System is a precision testing system designed to determine the tapped density and compaction behavior of powders under controlled tapping and environmental conditions. It provides accurate and repeatable measurements for battery electrode powders, pharmaceuticals, 3D printing powders, ceramics, and other fine particulate materials. The system supports automated protocols, high-resolution sensing, and compliance with global standards, enabling R&D, quality control, and process optimization.

Application

(1) Measurement of tapped density and compaction characteristics of lithium-ion, sodium-ion, and solid-state battery powders.

(2) Evaluation of pharmaceutical excipients and active pharmaceutical ingredients (APIs) for quality control and formulation studies.

(3) Testing of 3D printing powders, including metal, ceramic, and polymer powders, for additive manufacturing applications.

(4) Determination of powder properties for abrasives, catalysts, and food additives.

(5) Calculation of Hausner Ratio and Carr Index for flowability and packing behavior analysis.

(6) R&D and production-scale sample testing using variable cell volumes (1–500 cm³).

(7) Environmental testing under controlled temperature (-10°C to 80°C) and humidity (5–95% RH) conditions.

(8) Automated data acquisition and real-time plotting of tapped density vs. tap count for process optimization.

Standards

(1) ISO 3953 – Determination of tapped density of powders.

(2) ASTM B527 – Powder density measurement and compaction testing.

(3) CE/UL – Laboratory equipment safety compliance.

(4) USP – Powder density testing methods for pharmaceuticals.

(5) 21 CFR Part 11 – Electronic records and data integrity compliance for FDA-regulated applications.

Features

(1) Dynamic tapping mechanism: Programmable tapping cycles (1–3000 taps) with adjustable amplitude (1–50 mm).

(2) High-resolution sensing: Laser-based volume detection with ±0.01 cm³ accuracy.

(3) One-touch automated workflow: Preset protocols for USP or custom sequences; automatic calculation of Hausner Ratio and Carr Index.

(4) Real-time curve generation: Density vs. tap count, pressure, and environmental condition monitoring.

(5) Material versatility: Suitable for battery electrodes, pharmaceuticals, 3D printing powders, abrasives, catalysts, and food additives.

(6) Environmental monitoring: Integrated temperature (-10°C to 80°C) and humidity (5–95% RH) sensors with automatic drift correction.

(7) Pressure control: Closed-loop hydraulic system applies up to 500 MPa with ±0.1% FS stability.

(8) Certified calibration: NIST-traceable density standards (1 g/cm³, 2.5 g/cm³) for accurate verification.

(9) Safety features: Overpressure protection, emergency stop, HEPA-filtered dust containment, and anti-static handling.

(10) Connectivity: Wi-Fi/Bluetooth for remote monitoring; compatible with LIMS systems.

Parameters

ParameterSpecification
Tapping Range 1–3000 taps (adjustable speed: 10–60 taps/min)
Density Measurement 0.1–5.0 g/cm³ (±0.005 g/cm³ accuracy)
Pressure Application 0–370 MPa (programmable ramp rates)
Temperature Control -10°C to 80°C (±0.2°C stability)
Humidity Tolerance 5–95% RH (non-condensing)
Display/Interface 10.1" touchscreen with multi-language GUI
Power Consumption 600 W (110–240 V AC, 50/60 Hz)
Dimensions (W×D×H) 500 × 600 × 800 mm

Accessories

(1) Main Unit: Powder Tapped Density Analyzer with integrated safety enclosure.

(2) Software Package: Compliance-ready SPC software with FDA 21 CFR Part 11 modules.

(3) Testing Kits: Set of three stainless-steel density cells (10 cm³, 50 cm³, 250 cm³).

(4) Calibration Weights: 100 g and 500 g with certificates.

(5) Dust Management: HEPA filter unit and anti-static brush.

(6) User Documentation: Multilingual quick-start guide and maintenance manual.

Test Procedures

(1) Fill the powder sample into the designated density cell.

(2) Select the appropriate tapping protocol and set parameters such as tap number, amplitude, and speed.

(3) Start the test; the system automatically performs tapping while recording density, volume, and environmental parameters.

(4) Monitor real-time curves of density vs. tap count and review key metrics such as Hausner Ratio and Carr Index.

(5) Export test results for quality control, R&D, or regulatory documentation purposes.

Maintenance Information

(1) Inspect density cells, tapping mechanism, and sensors regularly for wear or contamination.

(2) Calibrate density measurement system periodically using certified reference standards.

(3) Keep the control system, touchscreen interface, and software environment clean and free from dust or moisture.

(4) Verify the functionality of safety interlocks, overpressure protection, and HEPA filters before testing.

(5) Lubricate moving components according to manufacturer recommendations to ensure smooth operation.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Compression Fatigue Testing Machine
Compression Fatigue Testing Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0959-2014 (China): Specifies compression fatigue testing protocols for inter...
Advanced glass bottle internal pressure resistance tester equipment
Advanced glass bottle internal pressure resistance tester equipment Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The design and manufacture of the internal pressure resistance tester for glass ...
Cleanable Filter Media Test System,ISO 12103 Cleanable Filter Media Test System
Cleanable Filter Media Test System,ISO 12103 Cleanable Filter Media Test System Whats/App: +86 156 1874 6768 Web: standard-groups.com The Cleanable Filter Media Test System is designed for characterizing cleanable filter medi...
Oxidizing Property Analyzer
Oxidizing Property Analyzer Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Description Conforms to UN Recommendations on the Transport of Dangerous Goods - M...
Cookware Scratch Resistance Tester
Cookware Scratch Resistance Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Primary applications Scratch and wear resistance testing for non-stick cookwa...
供应产品

Same products

Gasket for Plate Heat Exchanger
Gasket for Plate Heat Exchanger 卖方: Hengshui Hongcan Import and Export Trading Co., Ltd The sealing gasketin plate heat exchangers primarily serves to seal between hot and cold media. ...
Energy Saver
Energy Saver 卖方: O&K GROUP LIMITED Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies...
ER1100 Aluminum Welding Wire
ER1100 Aluminum Welding Wire 卖方: 868776 The ER1100 Aluminum Welding Wire from Hangzhou Kunli Welding Materials Co., Ltd. is designed for ...
air conditioner
air conditioner 卖方: O&K GROUP LIMITED Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies...
MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...