Double Plate Thermal Conductivity Apparatus

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Application

Building Engineering: Used to evaluate and optimize the thermal performance of building materials to improve the insulation and heat-resistant properties of buildings.

Industrial Engineering: Used to monitor and control the thermal conductivity performance of industrial equipment to improve production efficiency and reduce energy consumption.

Environmental Monitoring: Used to monitor and evaluate the environmental impact of building materials, such as thermal pollution and thermal environment.

Scientific Research: Used to research and develop new materials to improve their thermal conductivity and application value.

The design and operation procedures of these devices ensure the accuracy and reliability of measurements, providing important technical support for the fields of materials science and engineering.

Standards

GB/T 10294-2008:Determination of Steady State Thermal Resistance and Related Properties of Thermal Insulation Materials

GB/T 3399-1982:Test method for thermal conductivity of plastics - Heat - resistant plate method

GB/T 10801.1-2002:Thermal insulation polystyrene foam

GB/T 10801.2-2002:Extruded polystyrene foam

GB/T 3139-2005:Test method for thermal conductivity of fiber reinforced plastics

GB/T 17794-2008:Flexible foam rubber and plastic insulation products

ASTM C518:Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

IS0 8301:Thermal Insulation — Determination of Steady-State Thermal Resistance and Related Properties — Heat Flow Meter Apparatus

DIN EN 12667:Thermal Performance of Building Materials and Products - Determination of Thermal Resistance by Means of Guarded Hot Plate and Heat Flow Meter Methods - Products of High and Medium Thermal Resistance

Features

Chassis is nice. Test box shell uses spray method. It has strong mechanical strength, anti-corrosion

The device is small and the unique casters are designed to increase the flexibility of the thermometer movement.

High safety performance. It not only adopts the use of circuit and refrigeration cycle independent design, but also can ensure that the electrical part of the collected data from the impact of water, and improve stability.

Good performance of temperature stability and unique protection board design, can form a one-dimensional protection, so that it has no loss of temperature.

Online double standard company unique technology which can calibrate the temperature, calibration system error, is accurate, fast and convenient.

Technical Parameters

Items Parameters
Specimen standard size 300mm × 300mm × H (5 ~ 40) mm
Specimen flatness 0.1mm
Thermal conductivity measurement display range (0.001 ~ 2.000) W / (m • K)
Thermal conductivity measurement accuracy ± 3%
Thermal conductivity measurement Repeatability ± 1%
Temperature resolution 0.01 ℃
Temperature control accuracy 0.05 ℃
Different types of thermal conductivity tester temperature measurement range Model Cold plate temperature control interface ℃ Hot plate temperature control range ℃
IMDRY3001-I Room temperature - 95 ℃ Room temperature - 100 ℃
IMDRY3001-Ⅱ -℃ -5 ℃ - 95 ℃ 15 ℃ - 95 ℃
IMDRY3001-Ⅲ -10 ℃ - 95 ℃ 10 ℃ - 95 ℃
IMDRY3001-IV -15 ℃ - 95 ℃ 5 ℃ - 95 ℃
IMDRY3001-V -20 ° C - 95 ° C 0 ° C - 95 ° C
IMDRY3001-Ⅵ -30 ℃ -95 ℃ -10 ℃ -95 ℃
IMDRY3001-VII -40 ℃- 95 ℃ -20 ℃ - 95 ℃
Power supply AC 220V ± 10%, 2.5KW
Specimen thickness Standard 25mm, range (5 ~ 40) mm
Specimen thermal resistance requirements the thermal resistance of the specimen should not be less than 0.1 (m2 • K) / W, and should meet the thickness of the standard thickness Requirements; if the lower limit of thermal resistance of the specimen is as low as 0.02 (m2 • K) / W, the accuracy does not necessarily meet the requirements.
Clamping force No more than 2.5kPa

在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Carpet Static Electricity Tester
Carpet Static Electricity Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Test Principle When a person walks on the inspected carpet wearing the shoes specified in ...
Prefilled Syringe Plunger Force Tester
Prefilled Syringe Plunger Force Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications - Quality Control and Supervision The push - force tester for prefilled syrin...
Particle Abrasion Tester
Particle Abrasion Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Particle Abrasion Tester (Q-4D) is a precision instrument designed to measure the wear ...
Air Filter Flow Resistance and Efficiency Test Machine
Air Filter Flow Resistance and Efficiency Test Machine Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Filter Flow Resistance Test Bench is designed to evaluate the differentia...
Tibial Tray Fatigue Testing Machine
Tibial Tray Fatigue Testing Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0810 (China): Specifies fatigue testing protocols for tibial trays in total ...
供应产品

Same products

Laser Cutting Machines
Laser Cutting Machines 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Laser Cutting Machines PrecisionLaser Cutting Systemsfor Film, Glass & Industrial Materials ...
Precision Laser Micromachining Machine
Precision Laser Micromachining Machine 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Precision Laser Micromachining Machine| Ultrafast Laser Micromachining Systems Chanxan provides ...
Ultrafast Laser Systems
Ultrafast Laser Systems 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Ultrafast Laser Systems Femtosecond Laser System Ultra-precision femtosecond laser systemfor hi...
Industrial Laser Equipment Manufacturer
Industrial Laser Equipment Manufacturer 卖方: Chanxan (Changshu) Laser Technology Co., Ltd. Industrial Laser Equipment Manufacturer for Precision Cutting, Marking & Micromachining Chan...
Common Rail Injector Valve F00R J02 012
Common Rail Injector Valve F00R J02 012 卖方: 868983 Common Rail Injector Valve F00R J02 012 David Chen