Manikin Coughing System

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Application

HVAC education and research, including indoor air quality evaluation, human breathing exposure assessment in confined spaces, and cross-infection risk analysis of airborne diseases;

Medical and public health research, including studies on respiratory exposure, pollutant dispersion, and effectiveness of protective measures;

Occupational health assessment, such as evaluation of dust, PM2.5. and gaseous pollutant exposure in workshops and factories;

Breathing exposure assessment in aerospace cabins and confined environments, including civil and military aircraft, helicopters, space stations, re-entry capsules, submarines, and deep-sea systems;

Breathing exposure assessment inside vehicles and transportation systems, including buses, passenger cars, new energy vehicles, high-speed trains, subways, ships, and submarines;

Evaluation of breathing exposure and comfort of wearable masks, including space suits, pilot oxygen masks, aircraft passenger oxygen masks, and chemical protective mask systems.

Standards

GB/T 14296-2005 — Indoor Air Quality Evaluation Methods (Air Pollutant Exposure)

GB/T 18883-2022 — Indoor Air Quality Standard

ISO 7730:2005 — Ergonomics of the Thermal Environment — Analytical Determination and Interpretation of Thermal Comfort

ASTM F1291-2020 — Test Methods Related to Breathing and Exposure Measurement

Product Specifications

ComponentTechnical Parameters
Breathing Function Sinusoidal breathing profile; breathing frequency 10 breaths/min (one cycle 6.0 s: exhalation 2.0 s, inhalation 2.0 s, pause 2.0 s); customizable on request
Exhalation Volume Adjustable: 7 L/min, 15 L/min, 23 L/min; exhalation positive pressure 10–80 kPa (0.1–0.8 bar); inhalation negative pressure approx. −0.4 bar
Breathing Mode Switchable nasal breathing or oral breathing (when used with a thermal manikin)
Exhaled Airflow Equipped with heating module; airflow temperature adjustable from 34 to 36 °C
Sampling Branch Main breathing line includes a sampling port for aerosol or pollutant sampling
Electrical Control System Integrated control cabinet with pressure gauges and flow display; power supply AC 220 V / 50 Hz; total power ≤ 350 W; exhaled air heating module power ≤ 1000 W
Operating Environment Temperature 10–40 °C; humidity 15–95%
Others Can be used with a thermal manikin or independently with a manikin head; platform with lockable caster wheels; over-pressure and short-circuit protection; total weight approx. 45 kg

Accessories

Accessory / ConsumableSpecification
Breathing Control Cabinet Includes PID control, pressure gauges, and flow display modules
Heating Module Exhaled air heating module with adjustable temperature from 34 to 36 °C
Main Breathing Line Equipped with sampling branch for aerosol or pollutant sampling devices
Quick-Connect Cables For connection to thermal manikin or head model, easy installation and removal
Customizable Modules Nasal or oral breathing interfaces; child or infant manikin compatible modules

在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

STD-FB4-A computer controlled surface friction tester for textile engineering labs
STD-FB4-A computer controlled surface friction tester for textile engineering labs Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The Surface Performance Tester complies with the following standar...
Filter Membrane Pore Analysis Tester,ASTM F316 Compliant Pore Structure Tester
Filter Membrane Pore Analysis Tester,ASTM F316 Compliant Pore Structure Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Filter Membrane Pore Analysis Tester is a precision instrument designed to measure the ...
Rapid screening Calorimeter
Rapid screening Calorimeter Whats/App: +86 156 1874 6768 Web: standard-groups.com The rapid - screening calorimeter is a professional calorimetric instrument for the quick a...
Safety Helmet High Temperature Pre-Treatment Chamber
Safety Helmet High Temperature Pre-Treatment Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Main Purpose It is mainly used for the extremely high - temperature pre - treatment of saf...
ISO 1518 Surface Scratch Resistance Testing Machine for Paint Coatings
ISO 1518 Surface Scratch Resistance Testing Machine for Paint Coatings Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Surface Scratch Resistance Testing Machine is designed to evaluate the sc...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...