Manikin Coughing System
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
HVAC education and research, including indoor air quality evaluation, human breathing exposure assessment in confined spaces, and cross-infection risk analysis of airborne diseases;
Medical and public health research, including studies on respiratory exposure, pollutant dispersion, and effectiveness of protective measures;
Occupational health assessment, such as evaluation of dust, PM2.5. and gaseous pollutant exposure in workshops and factories;
Breathing exposure assessment in aerospace cabins and confined environments, including civil and military aircraft, helicopters, space stations, re-entry capsules, submarines, and deep-sea systems;
Breathing exposure assessment inside vehicles and transportation systems, including buses, passenger cars, new energy vehicles, high-speed trains, subways, ships, and submarines;
Evaluation of breathing exposure and comfort of wearable masks, including space suits, pilot oxygen masks, aircraft passenger oxygen masks, and chemical protective mask systems.
Standards
GB/T 14296-2005 — Indoor Air Quality Evaluation Methods (Air Pollutant Exposure)
GB/T 18883-2022 — Indoor Air Quality Standard
ISO 7730:2005 — Ergonomics of the Thermal Environment — Analytical Determination and Interpretation of Thermal Comfort
ASTM F1291-2020 — Test Methods Related to Breathing and Exposure Measurement
Product Specifications
| Component | Technical Parameters |
|---|---|
| Breathing Function | Sinusoidal breathing profile; breathing frequency 10 breaths/min (one cycle 6.0 s: exhalation 2.0 s, inhalation 2.0 s, pause 2.0 s); customizable on request |
| Exhalation Volume | Adjustable: 7 L/min, 15 L/min, 23 L/min; exhalation positive pressure 10–80 kPa (0.1–0.8 bar); inhalation negative pressure approx. −0.4 bar |
| Breathing Mode | Switchable nasal breathing or oral breathing (when used with a thermal manikin) |
| Exhaled Airflow | Equipped with heating module; airflow temperature adjustable from 34 to 36 °C |
| Sampling Branch | Main breathing line includes a sampling port for aerosol or pollutant sampling |
| Electrical Control System | Integrated control cabinet with pressure gauges and flow display; power supply AC 220 V / 50 Hz; total power ≤ 350 W; exhaled air heating module power ≤ 1000 W |
| Operating Environment | Temperature 10–40 °C; humidity 15–95% |
| Others | Can be used with a thermal manikin or independently with a manikin head; platform with lockable caster wheels; over-pressure and short-circuit protection; total weight approx. 45 kg |
Accessories
| Accessory / Consumable | Specification |
|---|---|
| Breathing Control Cabinet | Includes PID control, pressure gauges, and flow display modules |
| Heating Module | Exhaled air heating module with adjustable temperature from 34 to 36 °C |
| Main Breathing Line | Equipped with sampling branch for aerosol or pollutant sampling devices |
| Quick-Connect Cables | For connection to thermal manikin or head model, easy installation and removal |
| Customizable Modules | Nasal or oral breathing interfaces; child or infant manikin compatible modules |
在线联系供应商
Other supplier products
| STD-FB4-A computer controlled surface friction tester for textile engineering labs | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The Surface Performance Tester complies with the following standar... | |
| Filter Membrane Pore Analysis Tester,ASTM F316 Compliant Pore Structure Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Filter Membrane Pore Analysis Tester is a precision instrument designed to measure the ... | |
| Rapid screening Calorimeter | Whats/App: +86 156 1874 6768 Web: standard-groups.com The rapid - screening calorimeter is a professional calorimetric instrument for the quick a... | |
| Safety Helmet High Temperature Pre-Treatment Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Main Purpose It is mainly used for the extremely high - temperature pre - treatment of saf... | |
| ISO 1518 Surface Scratch Resistance Testing Machine for Paint Coatings | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Surface Scratch Resistance Testing Machine is designed to evaluate the sc... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |