Automatic luer conical joint multi-function apparatus
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
This tester is suitable for a broad range of medical Luer connection testing scenarios, including:
(1) Syringes (1 mL – 60 mL) – verifying leakage, torque, and assembly performance.
(2) Injection needles – testing connection integrity and unscrewing torque.
(3) Infusion sets and blood transfusion sets – assessing slip resistance and stress cracking under load.
(4) Catheters – evaluating connection reliability and sealing performance.
(5) Anesthesia filters – ensuring secure connections and prevention of leaks.
(6) Research and development of new Luer-type connectors – optimizing design for clinical use.
(7) Production line quality control – guaranteeing consistent performance across batches.
Standards
The tester complies with the following domestic and international standards for medical Luer connections:
(1) GB/T 1962.1-2015: Syringes – Luer lock and Luer slip connections (China)
(2) GB/T 1962.2-2001: Medical syringes – Performance testing (China)
(3) ISO 80369: Small-bore connectors for liquids and gases in healthcare applications (International)
(4) ASTM F2394: Standard test method for Luer connectors (International)
Parameters
| Parameter | Specification |
|---|---|
| Nominal capacity | 1 mL – 60 mL (optional) |
| Axial force | 0 – 100 N, error ≤ 0.5% |
| Separation force | 20 – 40 N, error ≤ 1% |
| Internal water pressure | 200 – 400 kPa, error ≤ 0.5% |
| Torque | 0.01 – 0.5 N·m, error ≤ 0.5% |
| Hold time | 1 – 60 s, error ≤ 1 s |
| Dimensions (L × W × H) | 450 × 350 × 400 mm |
| Net weight | 28 kg |
| Standards | GB/T 1962.1-2015. GB/T 1962.2-2001. ISO 80369. ASTM F2394 |
Accessories
(1) Main unit – 1 set
(2) Fixture adapters for different Luer sizes – 1 set
(3) Pressure calibration kit – 1 set
(4) Operation manual – 1 set
(5) Power cable – 1 set
在线联系供应商
Other supplier products
| Glove Cut Resistance Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: The machine is used to test the cutting resistance of gloves. Under ... | |
| Back, Body & Butt Forms for Ergonomic and Pressure Distribution Testing | Whats/App: +86 156 1874 6768 Web: standard-groups.com 5th Percentile Female SAE Butt Form The 5th Percentile Female SAE Butt Form is meticulousl... | |
| Battery Isothermal Calorimeter | Battery Isothermal Calorimeter is a professional instrument developed based on the principle of power compensation isothermal calorimetry for testi... | |
| Artificial turf wear tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com An artificial turf wear tester is a device specifically designed to evaluate the wear resis... | |
| Computer-controlled Helmet Impact Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com A computer-controlled helmet impact tester is an instrument used to test the impact resista... |
Same products
| Metal Angular Fixator Testing Machine | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Metal Angular Fixator Testing Machine... | |
| Bone Plate Four-Point Bending Fatigue Testing Machine | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Bone Plate Four-Point Bending Fatigue... | |
| Bone Plates Static Four - point Bending Tester | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Bone Plates Static Four-Point Bending... | |
| Spinal Internal Fixation System Assembly Testing Machine | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Spinal Internal Fixation System Assem... | |
| Spinal Internal Fixation System Component Testing Machine | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Spinal Internal Fixation System Compo... |