Automatic stapler blade tester equipment

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Applications

The sharpness tester for stapler blades is mainly used to assess the sharpness of blades for medical staplers, ensuring the quality of surgical instruments and the surgical outcome. Specifically, the tester simulates the process of the blades cutting materials, measures and analyzes parameters such as the force and displacement during cutting, and then determines the sharpness value of the blades. This test result not only provides important quality - control evidence for medical device manufacturers but also offers reliable reference data for medical workers when choosing surgical instruments.

Standards

YY/T 1797 - 2021: Surgical blades - Test method for sharpness and cutting performance

Technical Parameters

ParameterSpecification
Testing Accuracy ±0.01N
Testing Speed 0.05–600mm/min (Some models may vary, e.g., 600mm/min±30mm/min)
Testing Material Complies with the 3-0 uncoated silk-like twisted strand suture specified in YY0167-2005 (or other standard testing materials)
Power Supply 220V 50Hz; Overall Power Consumption: 70W (or other values)
External Dimensions 400×290×275mm (or other dimensions)
Net Weight 15kg (or other values)

Accessoriess

Standard configuration: Main unit, mini printer

Optional accessories: Professional software, communication cable

Test Procedures

1. Pre-test Preparation

Check the instrument's power supply (220V 50Hz) and component connections to ensure they are functioning correctly. Start the instrument and allow it to warm up to a stable operating state;

Calibrate the force sensor (ensuring an accuracy of ±0.01N), and prepare the test materials (such as 3-0 uncoated silk twisted suture as specified in YY0167-2005).

2. Sample and Test Medium Installation

Fix the stapler blade to be tested onto the instrument's dedicated fixture, ensuring the blade angle, position, and cutting path are aligned and there is no looseness/offset;

Install the test medium (such as standard suture) onto the cutting platform, adjusting its position to precisely align with the cutting edge of the blade.

3. Test Parameter Settings

Using the touchscreen interface, select the appropriate standard (YY/T 1797-2021), set the test speed (e.g., 0.05–600 mm/min), data acquisition frequency, and other parameters. Confirm and save the configuration.

4. Starting the Test

After confirming that the blade and medium are correctly positioned, click the "Start" button. The instrument will automatically simulate the cutting process, collecting and displaying cutting force, displacement, and other data in real time.

5. Test Process Monitoring

Observe the data changes on the interface to ensure that there are no abnormalities during the cutting process (such as blade jamming or medium displacement). If problems occur, pause and adjust immediately.

6. Test Completion and Cleanup

After the test is completed, the instrument will automatically shut down. Record/export the sharpness-related data (such as initial cutting force and displacement curve);

Loosen the fixture to remove the blade and remaining test medium, clean the fixture and cutting platform, turn off the instrument's power, and prepare the test report.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Sweating Thermal Manikin丨Sweating Thermal Manikin tester
Sweating Thermal Manikin丨Sweating Thermal Manikin tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards compliant ISO 15831:2004(E) Clothing-Physiological effects -Measurement of ASTM...
Scratch resistance test equipment
Scratch resistance test equipment Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Scratch Resistance Test Machine is suitable for a wide range of materials ...
Taber Linear Abraser
Taber Linear Abraser Whats/App: +86 156 1874 6768 Web: standard-groups.com TheTABER Linear Abraser (Abrader) - Model 5750has been engineered to evaluate product&rsquo...
Transparent Absorbing Wave Temperature and Humidity Vibration Test Chamber
Transparent Absorbing Wave Temperature and Humidity Vibration Test Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com The Transparent Absorbing Wave Temperature, Humidity, and Vibration Test Chamber is a hig...
Metal Angular Fixator Testing Machine
Metal Angular Fixator Testing Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com The Metal Angular Fixator Testing Machine is a specialized device used to evaluate the mech...
供应产品

Same products

Metal Angular Fixator Testing Machine
Metal Angular Fixator Testing Machine 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com The Metal Angular Fixator Testing Machine...
Bone Plate Four-Point Bending Fatigue Testing Machine
Bone Plate Four-Point Bending Fatigue Testing Machine 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com The Bone Plate Four-Point Bending Fatigue...
Bone Plates Static Four - point Bending Tester
Bone Plates Static Four - point Bending Tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com The Bone Plates Static Four-Point Bending...
Spinal Internal Fixation System Assembly Testing Machine
Spinal Internal Fixation System Assembly Testing Machine 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com The Spinal Internal Fixation System Assem...
Spinal Internal Fixation System Component Testing Machine
Spinal Internal Fixation System Component Testing Machine 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com The Spinal Internal Fixation System Compo...