Automatic catheter airflow resistance apparatus

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Applications

The catheter airflow resistance tester is an important tool for evaluating the resistance of gas flow in catheters. It is specifically designed to measure the airflow resistance inside medical devices such as breathing catheters. It is widely applied in multiple fields, including medical care, environmental protection, and the chemical industry. Especially in the production and quality - control processes of medical devices, this tester plays a crucial role. Through testing, it can ensure that catheter - related products like breathing tubes can meet the predetermined performance standards, thereby improving the overall product quality and production efficiency. In the medical field, the tester is used to assess the performance of breathing circuits for anesthesia machines and ventilators, ensuring that the products meet relevant standards and requirements.

Standards

YY0461 - 2003:Technical Requirements for Protective Masks for Medical Use

Technical Parameters

ParameterSpecification
Pressure Measurement Range Usually 0.01kPa to 10kPa; error ≤ ±1%; display resolution: 0.01kPa. This range covers airflow resistance measurement requirements for most catheters.
Flow Measurement Range Typically 0L/min to 50L/min (varies by tester model), enabling airflow resistance testing of catheters under different flow conditions.
Test Duration Usually 1 second to 10 minutes; error ≤ ±1 second. This range ensures test accuracy and stability.
Accuracy Pressure measurement accuracy: ±0.01kPa; flow measurement accuracy: ±2.5% (or lower, depending on specific model).

Accessoriess

Standard accessories: Dedicated clamps/connectors for different diameter tubes, airflow connecting tubing, sensor calibration parts, operating manual, and calibration certificate.

Optional accessories: Sample fixing bracket (for assisting tube installation), data export cable (for some models).

Test Procedures

1. Preparation

Ensure the instrument is in normal working condition and check that the power cord, sensors, and other components are intact. Connect the tubing and ensure a good seal between the tubing and the instrument interface.

2. Setting Parameters

According to the test requirements, set the relevant parameters of the instrument, such as flow rate and pressure measurement range.

3. Starting the Test

Start the instrument to begin the test. The instrument will automatically inject gas into the tubing and measure the pressure difference between the inlet and outlet. Based on the measurement results, the instrument will calculate the airflow resistance of the tubing.

4. Data Recording and Analysis

After the test is completed, the instrument will output the test results. The operator should carefully record this data and analyze it to evaluate the performance of the tubing.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Activated carbon wear resistance tester ​
Activated carbon wear resistance tester ​ Whats/App: +86 156 1874 6768 Web: standard-groups.com Applicable standards: GB/T 30202.3-2013: This is the wear resistance test standard in the ...
Helmet Webbing Micro - displacement Abrasion Tester
Helmet Webbing Micro - displacement Abrasion Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The helmet webbing micro-displacement wear testing machine is a comprehensive testing instr...
Electric Toothbrush Air Tightness Testing Equipment
Electric Toothbrush Air Tightness Testing Equipment Whats/App: +86 156 1874 6768 Web: standard-groups.com The Electric Toothbrush Air Tightness Testing Equipment is a dedicated instrument used to e...
OEM Ozone Aging Chamber for Automotive Wires
OEM Ozone Aging Chamber for Automotive Wires Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Automotive Wires Ozone Aging Chamber is designed to evaluate the ozone re...
Coatings Shear
Coatings Shear Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0856-2011 (China): Specifies mechanical testing protocols for metal angular ...
供应产品

Same products

HDPE高速水冷双壁波纹管生产线
HDPE高速水冷双壁波纹管生产线 卖方: Shandong HUASU Plastic Technology Co.,Ltd. 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功...
PanEVAP & MVR system
PanEVAP & MVR system 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...