Import Infusion Pump Flow Rate Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Applications
The infusion set flow rate tester is an instrument specifically designed for measuring and monitoring the flow rate of infusion sets. Its main uses include: - Flow Rate Measurement: Precisely measure the flow rate of the infusion set, usually displayed in milliliters per hour (ml/h) or drops per minute (gtt/min). - Flow Monitoring: Monitor the changes in flow rate in real - time during the infusion process, and promptly detect abnormal flow rate situations, such as the flow rate being too fast, too slow, or blocked, to ensure the safety and effectiveness of the infusion process. - Alarm Function: When the infusion flow rate exceeds the set normal range, the tester can emit audible and visual alarm signals to remind medical staff to take timely action and avoid potential medical risks. - Data Recording and Storage: Record and store information such as flow rate data and time during the infusion process, which is convenient for medical staff to view and analyze, and helps track and evaluate the patient's infusion treatment.
Standards
GB 8368 - 2018 : Disposable Infusion Sets
Technical Parameters
| Parameter | Specification |
|---|---|
| Testing Range | Wide flow rate testing range (e.g., 1 - 2000ml for some testers), adapting to different types/specifications of infusion sets (varies by catheter specifications) |
| Testing Accuracy | High accuracy for flow rate measurement (e.g., ±5ml/h or ±0.1gtt/min, etc.) to ensure test result accuracy |
| Static Water Level Height | Adjustable range: usually 0 - 1000mm, meeting requirements under different testing conditions |
| Temperature Control Range | Usually 5 - 90℃, simulating infusion situations under different temperature conditions |
| Fixtures | Adapt to various catheters; customized according to catheter specifications to firmly hold infusion sets of different specifications during testing |
| Flow Calculation | Adopts methods like the weighing method for flow calculation, ensuring accurate flow measurement |
| Alarm Threshold | Allows users to set the alarm threshold; triggers an alarm when the flow rate exceeds the set range |
Accessoriess
Standard accessories include: specialized fixing clamps for different types of infusion sets (for securely holding various infusion sets), connecting tubing (for setting up the flow path to complete flow rate testing), equipment calibration auxiliary parts (to ensure testing accuracy), operating manual, and calibration certificate.
Test Procedures
Infusion Flow Rate
For infusion sets with a drip rate of 20 drops/mL, the infusion set should deliver at least 1000 mL of sodium chloride solution [mass concentration p(NaCl) = 9 g/L] within 10 minutes under a static pressure head of 1 meter.
For infusion sets with a drip rate of 60 drops/mL, the infusion set should deliver at least 1000 mL of sodium chloride solution [mass concentration p(NaCl) = 9 g/L] within 40 minutes under a static pressure head of 1 meter.
在线联系供应商
Other supplier products
| Carpet Peel & Tuft Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Details For tufted carpets or traditional carpets, an important parameter is the r... | |
| Geosynthetics Horizontal Penetration Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The geosynthetic material horizontal permeability tester simulates water flow conditions in... | |
| Laboratory Air Filter Performance Test Rig | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) Filter Media Characterization: Performance testing of filter media accordi... | |
| Thermal Conductivity Tester for Silicone and Ceramic Substrates,ASTM D5470 industrial and lab material thermal tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Thermal Conductivity Tester for Silicone and Ceramic Substrates is a high-precision instrum... | |
| Dry and Wet Retroreflectometer | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards EN ISO 20471:2013 ANSI/ISEA 107-2015 GB 20653-2006 GB/T 18833 Main uses Dry... |
Same products
| HDPE高速水冷双壁波纹管生产线 | 卖方: Shandong HUASU Plastic Technology Co.,Ltd. | 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功... | |
| PanEVAP & MVR system | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... |