Alternative to PV Hail Impact Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
The Hail Impact Test Machine is suitable for a variety of testing and research scenarios:
Type testing and certification of PV modules
Factory inspection and quality control of PV modules
R&D evaluation of PV modules’ hail resistance
Impact durability testing of wind power and other photovoltaic building components
Climate simulation laboratories for mechanical impact studies
Safety and reliability assessment of solar PV systems
Standards
The machine is designed to meet the following key standards:
(1) GB/T 9535 – Crystalline Silicon Terrestrial Photovoltaic Modules – Design Qualification and Type Approval
(2) IEC 61215 – Terrestrial Photovoltaic Modules – Design Qualification and Type Approval
(3) IEC 61646 – Thin-Film Photovoltaic Modules – Design Qualification
(4) UL 1703 – Standard for Safety of Photovoltaic Modules
Parameters
| Item | Technical Specification |
|---|---|
| Launch Device Power | Compressed air from air compressor |
| Air Pressure | 6 – 8 bar |
| Ice Ball Loading | Manual single-shot |
| Barrel Length | ~940 mm, replaceable |
| X-Axis Travel | ~2100 mm |
| Y-Axis Travel | ~1000 mm |
| Positioning Accuracy | ≤1 mm |
| Impact Area | 2000 × 1000 mm |
| Guidance | High-precision imported rails |
| Drive | Imported servo motor + synchronous belt |
| Position Control | Automated via upper computer |
| Ice Ball Speed Measurement | Infrared sensor captures flight time t, V=S/t |
| Speed Accuracy | ±5% |
| Speed Range | 0 – 50 m/s |
| Ice Ball Impact Speed | 25 mm: 23.0 m/s ±5%; 35 mm: 27.2 m/s ±5%; 45 mm: 30.7 m/s ±5% |
| Ice Ball Diameter Deviation | ≤5% |
| Ice Ball Weight Deviation | ≤5% |
| Ice Ball Preparation Temperature | -10℃ |
| Ice Ball Mold | Inner diameter precision <1%; 1 mold 6 balls, at least 2 sets; CNC machined, deformation-resistant material |
Accessories
(1) Launch device – includes pneumatic system and barrel
(2) X/Y-axis positioning device – dual-axis servo system, rails, and control modules
(3) Ice ball speed measurement system – infrared sensor and data acquisition module
(4) Upper computer control system – automates impact and positioning
(5) Ice ball storage box – maintains low temperature storage
(6) Consumable ice ball molds – 1 mold 6 balls, at least 2 sets per size
(7) Consumable ice balls – 25. 35. 45 mm diameters, prepared as needed
(8) Optional replacement barrels – supports different calibers or worn barrel replacement
在线联系供应商
Other supplier products
| Photovoltaic module wire tube bending testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard IEC 61730-2:2004: Photovoltaic (PV) Module Safety Qualification – Require... | |
| Suitcases Vibration Impact Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com This machine is used to test the shock resistance of various luggage handles, car stitches ... | |
| ISO 6943 elastic fatigue resistance tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Elastic Tape Fatigue Testing Machineis used to determine its rep... | |
| Automatic oxidizing liquid tester apparatus | Whats/App: +86 156 1874 6768 Web: standard-groups.com Conforms to UN Recommendations on the Transport of Dangerous Goods - Manual of Tests and Cr... | |
| Particle Strength Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Particle Strength Tester is a high-precision instrument designed to measure the mechani... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |