20 Liter Explosion Test Chamber

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Applications

This instrument is used to measure the explosion index of dust or gas mixtures. The instrument uniformly sprays a dust or gas mixture into a confined space, and induces the test object to explode under the stimulation of an adjustable energy ignition source. The instrument measures the explosion index at the moment of explosion, including parameters such as the maximum explosion pressure pmax of dust, the maximum explosion pressure rise rate Kst, the lower explosion limit LEL of dust, the maximum explosion pressure pmax of gas, the maximum explosion pressure rise rate Kg, and the gas explosion limits (LEL and UEL), providing data support for the study of explosion suppression measures.

Standards

ASTM E1226:Standard Test Method for Minimum Ignition Energy of Dust Clouds in Air

ASTM E1515:Standard Test Method for Minimum Ignition Temperature of Dust Clouds by Electrically Heated Surface

EN 14034-1:Determination of Explosion Characteristics of Dust Clouds - Part 1: Determination of the Maximum Explosion Pressure (Pmax) and the Maximum Rate of Pressure Rise ((dp/dt)max) of Dust Clouds

EN 14034-2:Determination of Explosion Characteristics of Dust Clouds - Part 2: Determination of the Limiting Oxygen Concentration (LOC) for Dust Clouds

EN 14034-3:Determination of Explosion Characteristics of Dust Clouds - Part 3: Determination of the Minimum Ignition Energy (MIE) of Dust Clouds

EN 14034-4:Determination of Explosion Characteristics of Dust Clouds - Part 4: Determination of the Minimum Ignition Temperature (MIT) of Dust Clouds

EN ISO/IEC 80079-20-2:Explosive Atmospheres - Part 20-2: Equipment Protection Levels (EPL) - Classification of Equipment for Dust Atmospheres

ISO/IEC 6184/1:Explosive Atmospheres - Equipment for Explosive Gas Atmospheres - Part 1: General Requirements for Construction, Testing and Marking

ISO/IEC 6184/2:Explosive Atmospheres - Equipment for Explosive Gas Atmospheres - Part 2: Test Methods and Data for Determining Ignition Temperatures of Equipment Surfaces

Technical Parameters

Operating Environment

(5~45)℃, <85%RH

Explosive Vessel

20L ball with jacket

Vessel Pressure Resistance

Design pressure 3.0MPa@25℃

Sphere Material

Stainless steel 316

Sphere Operating Temperature

Maximum temperature 220℃

Sphere Volume

20L

Mezzanine Volume

1.5L

Diffusion Pressure Sensor

Range (0~3.5)MPa, overload pressure 10.5MPa,

Dispensing Pressure Sensor

Accuracy ±0.1% FS, working temperature (-40~105)℃

Explosive Pressure Detection

Range (0~200)kPa, overload pressure 600.0 kPa,

Explosive Pressure Detection Channels

Accuracy ±0.1% FS, working temperature (-40~105)℃

Explosive Temperature Sensor

Detection range (0~10.0)MPa, resolution 0.001MPa,

Dust Diffusion Vessel

Accuracy ±0.5%FS, response time<20μs

Powder Spraying Pressure

2 pcs

Nozzle Type

Detection range (0~1000)℃, resolution 0.01℃

Powder Spraying Delay Time

Capacity 0.6L, pressure resistance 2.5MPa

Ignition Mode

2.0MPa

Ignition Delay Time

Bounce back nozzle

Explosive Pressure Data Acquisition

(30~50)ms

Ignition Control

Chemical ignition: customer's own

Ignition Head Condition Detection

Electrostatic ignition: 15kV, 0.5s

Automatic Gas Dispensing

60ms

Vacuum System

Maximum collection rate 100 ks/s, recording time 1s

Snap Ring Diameter x Diameter

Remote wireless ignition support

Viewing Window

Electrochemical ignition head contact state and fusion state judgment

Interface

2 air intakes, 1 air inlet;

using partial pressure method of gas distribution, with an independent pressure sensor and electromagnetic valves, gas distribution accuracy ±1%. Solenoid valve, gas distribution accuracy ±0.1%

Power

Rotary vane vacuum pump, equipped with double impact filters to prevent residual substances from clogging and contaminating the pipeline, and easy to replace

Power

95mm

Dimensions

150mm

Operating Environment

Armored glass, 40mm in diameter

Accessoriess

1. 20L spherical explosion test container (with water circulation jacket to maintain a constant test environment temperature)

2. Dual ignition assembly: chemical igniter and electrostatic igniter (adaptable to different testing needs)

3. Dust sample diffusion device (works with compressed air to achieve uniform dust cloud distribution)

4. Automatic cleaning & vacuum module (for container pretreatment and post-experiment cleaning)

5. Pressure-time curve detection sensor (accurately collects pressure and time data during the explosion process)

6. Gas mixing assembly (enables configuration of gas/gas-solid mixtures at target concentrations)

7. Water circulation jacket connection piping (piping accessories to ensure constant container temperature)

8. Calibration standard dust sample (calibration components adapted to reference standards)


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Contact heating and cooling tester STD-F7
Contact heating and cooling tester STD-F7 Whats/App: +86 156 1874 6768 Web: standard-groups.com The sensation of coldness or warmth when skin touches a fabric is referred to as the "coldn...
Aluminum Tube Durability Tester
Aluminum Tube Durability Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The main purpose of the ductility tester for aluminum tubes is to evaluate th...
Athletic Footwear Shock Attenuating meter
Athletic Footwear Shock Attenuating meter Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard SATRA TM142 ASTM F1614 ASTM F1976 Product Advantages 1. Uncompromising Precis...
GX75 xenon weather meter for coatings testing
GX75 xenon weather meter for coatings testing Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The GX75 7.5kW Xenon Weather Meter is a high-performance accelerated aging sy...
Automated Scratch Testing Equipment (for Automatic Scratch Tester)
Automated Scratch Testing Equipment (for Automatic Scratch Tester) Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: It is suitable for printing, labeling, mobile shell, MP3/MP4 shell,...
供应产品

Same products

PanEVAP & MVR system
PanEVAP & MVR system 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...
PanPHE gasketed plate heat exchangers
PanPHE gasketed plate heat exchangers 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanPHE gasketed plate heat exchangersare designed with easy access for regular servicing and for ...