Custom garment shielding performance testing system

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The testing system supports compliance with the following standards:

GB 23463-2025 – Protective Clothing for Microwave Radiation

GB/T 33615-2017 – Methods for Testing Electromagnetic Shielding Performance of Garments

DIN 32780-100 – Protective Clothing, Part 100: Electromagnetic Field Protection in 80 MHz–1 GHz Range

IEC 61000-4-3 – Testing and Measurement Techniques for Radiated RF Electromagnetic Fields

ISO 105-X12 – Textiles: Color Fastness to Electromagnetic Effects (Reference for material durability)

Parameters

ParameterSpecification
Test Object Protective garments, including finished products and key raw materials
Test Environment Semi-anechoic chamber with low electromagnetic interference
Frequency Range 80 MHz – 1 GHz (standard)
Measurement Points Head, chest, abdomen of manikin
Sensors Embedded EMF receiving sensors in manikin
Radiation Source Signal amplifier with directional transmitting antenna
Shielding Effectiveness Measurement Vector Network Analyzer (VNA)
Environmental Conditions Controlled temperature and humidity to minimize measurement variability
Data Output Real-time attenuation curves and shielding performance reports
Power Supply AC 220V, 50/60 Hz
Footprint Chamber and system optimized for laboratory installation

Features

Realistic simulation of human exposure using test manikin

Semi-anechoic chamber minimizes external electromagnetic interference

High-precision vector network analyzer measures shielding effectiveness accurately

Multi-point measurement captures shielding at head, chest, and abdomen

Supports evaluation of raw materials, components, and finished garments

Integrated software for data acquisition, analysis, and automatic report generation

Capable of long-term performance evaluation including wash and abrasion tests

Test Procedures

Sample Preparation

Include finished garments and critical raw materials to evaluate both overall and component-level shielding.

Ensure garments are properly mounted on the manikin with sensors correctly positioned.

Environmental Control

Conduct testing in a low-noise, semi-anechoic chamber to minimize external electromagnetic interference.

Measurement

Activate the electromagnetic radiation source and record real-time attenuation at head, chest, and abdomen using the manikin sensors.

Use the Vector Network Analyzer to measure shielding effectiveness across the target frequency range.

Durability Assessment

Optionally perform wash, friction, and other stress tests on the garment before re-evaluating shielding performance.

Data Recording

Analyze and record results with integrated software, generating performance curves and standardized reports.

Maintenance Information

Regularly inspect and calibrate the vector network analyzer and sensors to ensure accuracy

Maintain semi-anechoic chamber cleanliness and check shielding integrity periodically

Verify signal amplifier and antenna operation before each test

Ensure environmental sensors are functional and provide accurate temperature and humidity readings

Store manikin and sensitive components properly when not in use to prevent mechanical or electrical damage


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

UV Sterilizer
UV Sterilizer Product introduction of Environmental test chamber Ultraviolet disinfection technology is the latest generation of disinfection technology emergin...
Photovoltaic module outdoor exposure test system
Photovoltaic module outdoor exposure test system The Photovoltaic Module Outdoor Exposure Test System is designed to simulate real-world environmental conditions for accelerated aging and performa...
Fabric Fiber Shedding Degree Tester (Friction)
Fabric Fiber Shedding Degree Tester (Friction) The Fabric Fiber Shedding Degree Tester (Friction) is an instrument used to evaluate the light-blocking performance of fabrics and is widely used i...
Thrust Bearing Rolling Friction and Wear Testing Machine
Thrust Bearing Rolling Friction and Wear Testing Machine Applicable Standards: ASTM D3702 ASTM G99 ASTM G77 ISO 18535 Product Advantages: Simulates Real-World Conditions: Allows testing under contro...
PV Hail Impact Tester
PV Hail Impact Tester Standard Compliance IEC 61215: Mechanical load testing for terrestrial photovoltaic modules. UL 61730: Safety standards for photovoltaic modules ...
供应产品

Same products

Custom five-finger scratch testing system
Custom five-finger scratch testing system 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Five-Finger Scratch Tes...
Cross cut adhesion testing equipment supplier
Cross cut adhesion testing equipment supplier 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards PV 3952 Plastic interior parts...
Automatic radiant protective performance tester
Automatic radiant protective performance tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Outdoor Sports Gear: Evaluat...
Clothing Wearing Tactile Pressure Tester
Clothing Wearing Tactile Pressure Tester 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application You use this tester to asses...
Splash and spray liquid resistance testing system supplier
Splash and spray liquid resistance testing system supplier 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Application You use this tester to asses...