Industrial expansion tank static pressure tester supplier

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

The system supports compliance with major automotive engineering standards:

VW TL889 (4.1) – Volkswagen Group technical specification for interior and related component functional performance.

ESDG93-8A080-AA (3.6) – Ford engineering specification for component functionality and reliability.

GMW15310 (3.2.1.2) – General Motors global standard for material and component performance testing.

QV17004D (3.2.6) – BMW group specification for system component functionality and durability.

Parameters

Parameter CategoryDetails
Test Bench Dimensions 2200 × 2240 × 1550 mm (W × H × D)
Chamber Dimensions 1000 × 800 × 1000 mm (W × H × D)
Rated Power 9.5 kW
Test Medium Glycol/Water
Pressure Range 0 … 5 bar
Flow Rate per Sample 0 … 8 l/h
Pressure Type Static
Test Medium Temperature Range 25 … +150°C
Environmental Temperature Range 25 … +150°C
Test Channels 6

Features

Designed specifically for static pressure testing of expansion tanks.

Static pressure adjustable from 0 up to 5 bar.

Individual sample flow rate controllable from 0 to 8 l/h.

Explosion protection level 1 due to indirect chamber heating.

Automatic leak detection and leak testing with fail-safe shutdown of defective samples.

Automatic control of liquid level during testing.

Accessories

Indirectly heated test chamber

Flow control units for each sample

Leak detection sensors and safety interlocks

Liquid level monitoring and control system

Control unit with Windows/LabVIEW interface (optional for data logging)

Sample mounting brackets for expansion tanks

Test Procedures

Ensure the test area is clear and safe for operation.

Connect the system to the 9.5 kW power supply.

Fill the chamber and sample lines with glycol/water mixture.

Mount expansion tank samples in the test chamber.

Set the static pressure (0–5 bar) and flow rate (0–8 l/h) for each sample.

Activate the test system and indirect heating if required.

Monitor pressure, flow, and leak detection sensors throughout the test.

Automatically shut down any failed samples.

Record all test results for quality control or validation purposes.

After testing, safely drain the medium and allow the system to cool before removing samples.

Maintenance Information

Inspect sample mounting brackets, pressure sensors, and leak detection units before each test.

Verify flow control devices and chamber seals for proper operation.

Periodically calibrate pressure sensors and temperature controllers.

Clean the chamber and fluid circuits to prevent contamination.

Replace worn or defective components to maintain safe and accurate operation.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Pipe coating scratch tester
Pipe coating scratch tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Pipe Coating Scratch Tester, also known as a paint and varnish scratch resistance teste...
IEC 62196 EV Charging Gun Air Tightness Tester Manufacturer
IEC 62196 EV Charging Gun Air Tightness Tester Manufacturer Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) GB/T 20234.1-2023 – Connection set for conductive chargi...
High-precision thermal conductivity tester for silicone and ceramic materials
High-precision thermal conductivity tester for silicone and ceramic materials Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This tester is suitable for testing: Thin heat conductors and metals Solid e...
ISO 10717 zipper fatigue test
ISO 10717 zipper fatigue test Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Zipper reciprocating tester measures zipper performance in products like clot...
Demesia Zigzag Tester
Demesia Zigzag Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Demesia Zigzag Tester is a professional device used to test the flexural resistance of ...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...