Custom Squirrel Cage Smoke Toxicity Testing Equipment for R&D
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The test apparatus complies with the following national and international standards:
(1) GB/T 20285-2006 – Classification for Toxic Hazard of Smoke Generated by Materials
(2) ISO 19700:2006 – Controlled Equivalence Ratio Method for the Determination of Hazardous Components of Fire Effluents
(3) DIN 53436 – Testing of Thermal Decomposition Products of Materials under Ventilated Conditions and Their Toxicological Evaluation
Parameters
| Item | Specification |
|---|---|
| Quartz Tube & Quartz Boat | Made of quartz glass |
| Quartz Tube Nominal Diameter | (36 ± 1) mm |
| Quartz Tube Wall Thickness | (2 ± 0.5) mm |
| Quartz Tube Length | 1000–1300 mm |
| Quartz Tube Support | Adjustable horizontally and vertically |
| Smoke Collection & Distribution Assembly | Three-way stopcock, dilution gas inlet pipe, gas distribution elbow |
| Gas Flow Pipe Nominal Diameter | (36 ± 1) mm |
| Mouse Rotating Cage | Aluminum plate stamping |
| Rotating Cage Mass | (60 ± 10) g |
| Exposure Chamber | Transparent organic glass |
| Exposure Capacity | Up to 10 mice simultaneously |
| Temperature Control System | Thermocouple, cold-junction compensation, temperature controller, digital display |
| Furnace Movement Drive | Stepper motor |
| Movement Speed | (10 ± 0.1) mm/min |
| Adjustable Speed Range | 5–50 mm/min |
| Maximum Travel Distance | > 600 mm |
| Carrier & Dilution Gas | Compressed air |
| Air Flow Rate | 0–20 L/min adjustable |
Features
Designed specifically according to GB/T 20285-2006 for smoke toxicity hazard classification of materials.
Ring furnace adopts an energy-saving full-fiber furnace tube structure with stable thermal performance.
High-precision temperature control system ensures furnace temperature meets the requirements of Chapter 7 of GB/T 20285.
Stepper-motor-driven furnace displacement system provides low noise, high accuracy, and flexible speed selection.
Quartz tube and joints are precision ground and paired during processing to ensure excellent sealing performance.
Waste gases generated during testing are directly discharged into the ventilation duct through plastic hoses, preventing smoke leakage in the working area.
Transparent exposure chamber allows visual observation of test animals during exposure.
Mouse rotating cages are designed to rotate freely, preventing fixed postures and reducing the risk of mechanical injury.
Integrated carrier gas and dilution gas supply system ensures stable smoke concentration control.
Computer-based control system enables high automation and real-time monitoring of test parameters.
Accessories
(1) Ring furnace heating system
(2) Quartz tube
(3) Quartz boat
(4) Smoke collection and distribution assembly
(5) Transparent organic glass exposure chamber
(6) Mouse rotating cages
(7) Temperature control and furnace displacement system
(8) Carrier and dilution gas supply components
(9) Computer control software system
Test Procedures
Specimen Installation
Prepared specimens are placed into the quartz boat and positioned at the specified location inside the quartz tube.
Animal Placement
Experimental mice are placed into the aluminum rotating cages, ensuring free rotation without fixed stationary points to avoid injury or restricted movement.
System Startup
The industrial computer and control software are started, and a preset test program is selected.
The ring furnace is heated to the required temperature, and once stable, the furnace begins uniform scanning movement to heat the specimen.
Exposure and Monitoring
Smoke is diluted by carrier air and introduced into the exposure chamber, where mice are exposed for 30 minutes.
The software displays temperature curves, airflow rate, and furnace displacement in real time while animal behavior is observed.
Data Collection
Smoke concentration and related parameters are automatically recorded.
After the test, the system generates and prints test data, including time-temperature curves and mouse survival information.
Maintenance Information
Regular inspection of the quartz tube, sealing joints, and gas pipelines is recommended to maintain proper sealing and safe operation. The temperature control system and furnace displacement mechanism should be periodically checked to ensure accuracy and smooth movement. After testing, the exposure chamber and quartz components should be cleaned to prevent residue accumulation. Software data should be backed up regularly, and sensor calibration should follow laboratory quality management requirements.
在线联系供应商
Other supplier products
| PV Degradation Testing Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Light Decay Test Chamber is designed as an indoor exposure system, primar... | |
| Gas Oxidizing Property Tester | Product Description Conforms to ISO 10156-2010 “Gases and Gas Mixtures Selection of Cylinder Valve Exhaust Ports by Determination of Combust... | |
| Syringe Sealing Negative Pressure Test device | Meet the standard YY0053-2008. GB 15810-2019 single-use sterile syringe, ISO7886-1:2017 single-use sterile syringe, ISO7886-1. ISO8537-2016. YY04... | |
| Rubber Non-Rotor Vulcanization Measuring Apparatus | Product Introduction: Non-rotor vulcanizer is a rubber processing industry control rubber material quality, rapid inspection and rubber basic rese... | |
| Adiabatic Accelerated Calorimeter | Product Description Adiabatic Accelerated Calorimeter determines the thermal behavior of samples under adiabatic conditions by keeping the tempera... |
Same products
| ISO 29463 HEPA/ULPA filter performance testing System | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system supports and compli... | |
| High-Precision ISO 16890 Filter Media Test Rig for R&D and QC | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system can execute and com... | |
| Mobile Floor Scrubber Aging Life Tester IEC 60312 | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheMobile Floor Scrubber Aging L... | |
| ISO 12103 Cleanable Filter Media Test System | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The system complies with: (1)... | |
| Robotic Vacuum Cleaners Edge-Following Tester | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com TheEdge-Following Test Equipment... |