Automatic catheter vacuum leak apparatus

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

GB 15812.1 - 2005 :Non - Vascular Intravascular Catheters - Part 1: General Performance Test Methods

GB 8368 :Disposable Infusion Sets

YY 0489 - 2004 :Test Method for Piston Tightness of Disposable Sterile Syringes

Features

1. High-precision measurement: It can quickly and accurately detect the location and size of leaks in the pipeline system, enabling precise measurement of minute pressure changes and flow differences.

2. Safe and reliable: It prevents safety accidents and quality problems caused by leaks, ensuring the safety and stability of the production process.

3. Easy to operate: The operation interface is simple and clear, allowing users to complete the testing process by following the prompts. Some testers also feature user-level access control and a comprehensive password protection scheme to ensure data integrity, standardization, and traceability.

4. Multifunctional: Some advanced testers offer features such as real-time data display, data recording and analysis, test report generation, and multiple testing modes, meeting the needs of different users.

Technical Parameters

ParameterSpecification
Measuring Range Usually 0 to -90kPa, which can meet the negative-pressure testing requirements of various catheters
Accuracy Generally reaching level 0.1 to ensure the accuracy of test results
Vacuum Maintenance Performance Equipped with an automatic pressure-holding function to ensure the stability of the vacuum during the test
Test Time Setting range: 1 to 9999 seconds; error ≤ ±1 second
Power Supply Usually 220VAC 50Hz or 120VAC 60Hz, adapting to voltage requirements of different regions
Net Weight Approximately 20kg (varies by model)

Accessoriess

Standard accessories include: specialized connection adapters for different sizes of medical catheters (compatible with various catheter interfaces such as suction tubes and drainage tubes), vacuum-sealed connecting tubing (for connecting the main unit to the vacuum tank), sample fixing clamps (to secure the catheter under test), standard leak calibration components (to ensure the accuracy of the equipment's measurements), operating instructions, and a calibration certificate.

Test Procedures

Open-system catheter: Open the catheter vacuum control device to the release position, turn on the vacuum pump, and adjust the flow rate to the specified value (e.g., 30 L/min).

Closed-system catheter: Remove the pressure gauge, turn on the vacuum control device and vacuum pump, adjust the flow rate to the specified value, then switch the vacuum control device to the closed position, and reattach the pressure gauge. Read and record the residual vacuum value measured on the pressure gauge, which is usually expressed in kPa. For respiratory tract suction catheters, the residual vacuum should not exceed the specified value (e.g., 0.33 kPa or 3.4 cmH₂O).


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

oxygen index apparatus丨oxygen index device
oxygen index apparatus丨oxygen index device Whats/App: +86 156 1874 6768 Web: standard-groups.com The oxygen index flammability testeris, perhaps, the most economical and precise quality co...
Thermal Conductivity Tester (Heat Flow Method),ASTM D5470 heat flow thermal conductivity measurement device
Thermal Conductivity Tester (Heat Flow Method),ASTM D5470 heat flow thermal conductivity measurement device Whats/App: +86 156 1874 6768 Web: standard-groups.com Thermal Conductivity Tester (Heat Flow Method) is a high-precision instrument designed for ...
Safety Helmet High Temperature Pre-Treatment Chamber
Safety Helmet High Temperature Pre-Treatment Chamber The safety helmet high-temperature pre-treatment chamber is manufactured according to the GB/T2812-2019 standard for safety helmets and is primaril...
Scratch tester STD-KK03
Scratch tester STD-KK03 Introduction With the continuous expansion of the use of plastic molding products, from the point of view of the surface appearance of molded prod...
In-situ Gas Analysis System for Lithium Battery Thermal Runaway,thermal runaway gas monitoring system
In-situ Gas Analysis System for Lithium Battery Thermal Runaway,thermal runaway gas monitoring system Whats/App: +86 156 1874 6768 Web: standard-groups.com The In-situ Gas Analysis System for Lithium Battery Thermal Runaway is an advanced testing ...
供应产品

Same products

Mini Jewelry Laser Welding Machine
Mini Jewelry Laser Welding Machine 卖方: Beijing JCZ Technology Co., Ltd The Mini Jewelry Laser Welding Machineis an advanced mini laser welding system engineered for pre...
Pulse Laser Cleaner | Handheld Solution for Precision Surface Cleaning for Rust & Coating
Pulse Laser Cleaner | Handheld Solution for Precision Surface Cleaning for Rust & Coating 卖方: Beijing JCZ Technology Co., Ltd Looking for an efficient and eco-friendly laser cleaning machine? The HCP Series Pulse Laser Clea...
Mini Type Laser Marking & Engraving Machine – Fiber & UV Laser Options for Precise Marking
Mini Type Laser Marking & Engraving Machine – Fiber & UV Laser Options for Precise Marking 卖方: Beijing JCZ Technology Co., Ltd This compact, Mini Type fiber laser marking machineis perfectly suited for small businesses, work...
Large Enclosed Laser Marking & Engraving Machine for Industrial Use
Large Enclosed Laser Marking & Engraving Machine for Industrial Use 卖方: Beijing JCZ Technology Co., Ltd The Large Closed Laser Marking Machineis a high-performance engraving solution designed for indus...
Axial force wire guide apparatus
Axial force wire guide apparatus 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards YYT0807 - 2010 :Standard Guide...