High-Precision Thermal Constants Testing Equipment
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The analyzer supports multiple internationally recognized test methods and standards, including:
(1) ISO 22007-2: Plastics — Determination of thermal conductivity and thermal diffusivity — Transient plane heat source method
(2) ISO 22007-7: Plastics — Determination of thermal conductivity and thermal diffusivity using transient plane heat source
(3) GB/T 32064: Transient plane heat source method for thermal conductivity and thermal diffusivity of building materials
(4) ASTM E3088: Standard test method for determination of thermal conductivity and thermal diffusivity using the transient plane source method
(5) ASTM D7896: Transient hot-wire method for thermal conductivity, thermal diffusivity, and volumetric heat capacity of liquids
(6) ASTM D5334: Transient line-source probe method
(7) ASTM D5930: Determination of thermal conductivity of plastics by transient line-source technique
(8) IEEE 442: Soil thermal resistivity measurement
Parameters
| Method | TPS | THW | MTPS | THS | TLS |
|---|---|---|---|---|---|
| Applicable Materials | Solids, pastes, powders | Liquids, phase-change materials | Solids, pastes, powders | Solid rectangular samples | Soil, pastes, polymers |
| Measurement Mode | 3D bulk, anisotropic, plate, thin film, 1D | Bulk | 3D bulk, anisotropic, plate, 1D | Bulk, anisotropic | Bulk |
| Thermal Conductivity (W/m·K) | 0.005–2000 | 0.01–2 | 0.03–500 | 0.01–2 | — |
| Thermal Diffusivity (mm²/s) | 0.01–1200 | Up to 0.5 | 0.01–300 | Up to 0.5 | — |
| Volumetric Heat Capacity (MJ/m³·K) | Up to 5 | Up to 5 | Up to 5 | Up to 5 | — |
| Thermal Effusivity (W·s½/m²·K) | 5–60000 | Not applicable | 20–40000 | Not applicable | — |
| Contact Thermal Resistance (m²·K/W) | Measured | Not applicable | Measured | Not applicable | Not applicable |
| Sample Thickness (mm)* | ≥0.01 | — | ≥0.1 | — | — |
| Test Time (s) | 0.25–2560 | 1 | 0.25–2560 | 0.25–2560 | 180 |
| Accuracy (Thermal Conductivity) | 3% | 2% | 5% | 5% | 5% |
| Repeatability (Thermal Conductivity) | 1% | 1% | 2% | 2% | 2% |
| Temperature Range (°C)** | 0 to 300 / up to 750 or 1000 | 10 to 200 | 0 to 100 / −50 to 200 | −75 to 300 | −40 to 100 |
| Sample Configuration | Symmetric / asymmetric | Insert type | Asymmetric (single-sided) | Symmetric / asymmetric | Insert type |
Features
Supports multiple transient methods within one integrated system
Measures absolute thermal conductivity, thermal diffusivity, specific heat, and thermal effusivity
Suitable for solids, liquids, pastes, powders, and soil samples
Wide thermal conductivity and temperature measurement ranges
Direct measurement of sensor–sample contact thermal resistance for improved accuracy
Accessories
(1) Transient plane heat source (TPS) sensors
(2) Transient hot-wire (THW) sensors
(3) Modified transient plane source (MTPS) sensors
(4) Transient hot strip (THS) sensors
(5) Transient line source (TLS) probes
(6) Sample holders for solid, liquid, and soil configurations
Test Procedures
Select the appropriate measurement method based on sample type and test requirements.
Prepare and position the sample according to the selected method and configuration.
Place the corresponding sensor in contact with or within the sample as required.
Set test parameters such as temperature range and measurement time.
Initiate the test; transient thermal signals are generated and recorded automatically.
The system calculates thermal conductivity, thermal diffusivity, specific heat, and related properties based on the acquired data.
Maintenance Information
Keep all sensors clean and free from surface contamination to ensure stable contact conditions.
Periodically inspect sensor surfaces for wear or damage, especially when testing rough samples.
Verify calibration and system performance at regular intervals using reference materials.
Store sensors and probes in protective containers when not in use to prevent mechanical damage.
在线联系供应商
Other supplier products
| Automatic European Standard Washer for Colorfastness and Shrinkage Testing | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Feature (1) Multi-layer design with flange plate for stress distribution and... | |
| High-Precision Multi-Functional Wear Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The Multi-Function Friction and Wear Tester is designed to support test methods ... | |
| Fabric Vertical Flame Spread Test Machine with ISO 6941 | Whats/App: +86 156 1874 6768 Web: standard-groups.com Products: This machine is suitable for one-component or multi-component (coating, quilt, l... | |
| Battery needling tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com System overview: The cylindrical battery volume expansion in-situ test system provides acc... | |
| Chemical Protective Clothing Testing Equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This equipment is used for the following applications: (1) Performance evalua... |
Same products
| 不锈钢焊剂芯焊丝 E308T1-1 E308HT1-1 E308LT1-1 用于304不锈钢焊接的气保焊丝 | 卖方: 863048 | 产品描述 不锈钢药芯焊丝 E308T1-1 E308HT1-1 E308LT1-1,FCAW不锈钢焊丝,AWS A5.22药芯焊丝,304不锈钢焊接耗材,低碳不锈钢药芯焊丝,耐高温不锈钢焊丝,... | |
| E317LT1-1 焊剂芯线 CO2 不锈钢焊剂含量70% 直径1.0/1.2/1.6mm OEM定制 1200℃熔点 | 卖方: 863048 | 迅卓不锈钢药心焊丝 E317LT1-1 分类: Сварочная проволока E317LT1-1 с флюсом, нержавеющая сталь, 70% содержан... | |
| Mini Jewelry Laser Repair System – 60W to 400W Precision Welding | 卖方: Beijing JCZ Technology Co., Ltd | The Mini Jewelry Laser Welding Machineis an advanced mini laser welding system engineered for pre... | |
| Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal | 卖方: Beijing JCZ Technology Co., Ltd | TheHCP-M SeriesBackpack Laser Cleaning Machinefeatures a compact pulsed fiber laser system, desig... | |
| Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner | 卖方: Beijing JCZ Technology Co., Ltd | The Suitcase Pulsed Laser Cleaning Machineis an ultra-portable, high-precision handheld fiber las... |