Laboratory Hot-Wire Thermal Conductivity Tester for Liquids
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
The analyzer is designed and tested in accordance with internationally recognized standards:
ASTM D7896-19 — Standard Test Method for Thermal Conductivity, Thermal Diffusivity, and Volumetric Heat Capacity of Liquids Using the Transient Hot-Wire Method
Parameters
| Parameter | Configuration 1 | Configuration 2 | Configuration 3 |
|---|---|---|---|
| Material | Liquids & phase change materials | Liquids & phase change materials | Liquids & phase change materials |
| Thermal Conductivity (W/m·K) | 0.01 – 2 | 0.01 – 2 | 0.01 – 2 |
| Additional Properties | Thermal diffusivity, specific heat | Thermal diffusivity, specific heat | Thermal diffusivity, specific heat |
| Viscosity Range (cP) | 0.001 – 10.000.000 | 0.001 – 10.000.000 | 0.001 – 10.000.000 |
| Sample Volume (mL) | 20 | 20 | 20 |
| Test Time (s) | 1 | 1 | 1 |
| Accuracy (Thermal Conductivity)* | ±2% | ±2% | ±2% |
| Repeatability (Thermal Conductivity)* | ±1% | ±1% | ±1% |
| Temperature Range (°C) | 10 to 200 | -40 to 200 | -160 / -40 / 0 to 300 |
| Pressure (bar) | Up to 20 | Up to 20 | Up to 35 |
| External Cooling Required | No | Yes | Yes |
| Standard | ASTM D7896-19 | ASTM D7896-19 | ASTM D7896-19 |
Features
Transient hot-wire method with ultra-fast 1-second measurement
High accuracy and excellent repeatability for liquid thermal properties
Non-steady-state measurement minimizes convection effects, even for high-viscosity samples
Small sample volume requirement (20 mL)
Wide viscosity, temperature, and pressure measurement capability
Fully compliant with ASTM D7896-19
Accessories
(1) Paste and PCM element — Designed for easy loading of phase change materials; spring-loaded structure accommodates thermal expansion and contraction while maintaining contact with the THW wire
(2) Observation element — Glass viewing port for monitoring sample conditions such as phase separation, boiling, or particle sedimentation
(3) Ambient density powder element — Suitable for basic powder testing at ambient pressure
(4) Variable density powder element — Spiral compression system allows density adjustment and stable wire contact
(5) Vertical element holder — Enables vertical loading for paste, PCM, and powder elements
(6) Cooling system options —
Economic circulator: down to 0 °C
Circulator: down to -15 / -35 / -50 °C
Advanced options: down to -100 / -150 °C
Test Procedures
Sample Preparation
Pour approximately 20 mL of liquid into the selected sample element. The short test duration effectively suppresses convection, allowing accurate measurement across a wide viscosity range. Back pressure up to 35 bar can be applied for measurements above the boiling point.
Approximate time: 1 minute
Sensor Insertion
Insert the THW sensor into the sample element and place it into the integrated temperature platform for controlled testing.
Approximate time: 1 minute
Measurement Execution
The software automatically controls isothermal steps from -150 °C to 300 °C, depending on configuration.
Approximate time: < 1 minute
Result Output
The Windows-based software verifies measurement validity, suggests adjustments if required, and generates reports. Results can be saved, exported to Excel, or sent via .
Approximate time: 1 minute
Maintenance Information
Keep the THW sensor clean and free of residue after each test
Inspect sensor integrity regularly to ensure stable resistance behavior
Verify temperature control performance periodically
Store sample elements in a clean, dry environment
Follow standard laboratory practices for handling liquids and phase change materials
在线联系供应商
Other supplier products
| Thermal Radiation Flame Propagation Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The instrument complies with domestic and international standards, including: N... | |
| Bench-top PV Hail Impact Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards IEC 61215: Mechanical load testing for terrestrial photovoltaic modules UL 6173... | |
| Laboratory Liquid Thermal Conductivity Analyzer Using Hot Wire Method | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The analyzer is designed and tested in accordance with internation... | |
| Walk-In Drug Stability Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards WHO Principles Require: Long-term stability testing conditions at 25°C/60% ... | |
| Foam Repeated Compression Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Foam repeated compression testing machine will accurately measure the thickness of the test... |
Same products
| Laser Chuck | 卖方: 00000 | Laser Chuck Introduce foreign advanced technology and management concept, High precision pro... | |
| Power Pallet Jack For Sale | 卖方: Jinan Hulk Machinery Co., Ltd | Power Pallet Jack For Sale Electric Pallet Truck For Sale As a supplier of power pallet jac... | |
| Multi Directional Forklift For Sale | 卖方: Jinan Hulk Machinery Co., Ltd | Multi Directional Forklift For Sale Multi Directional Forklift For Sale As a supplier of mu... | |
| Narrow Aisle Forklift For Sale | 卖方: Jinan Hulk Machinery Co., Ltd | Narrow Aisle Forklift For Sale Narrow Aisle Forklift For Sale As a supplier of , we provide... | |
| Electric Order Picker Supplier | 卖方: Jinan Hulk Machinery Co., Ltd | Electric Order Picker Supplier Electric Order Picker Supplier As an supplier, we offer a co... |