Gas turbine air filtration testing equipment supplier
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Test System for testing air intake filter systems for rotary machinery (ISO 29461). The test system for testing air intake filter systems for rotary machinery is based on the well-established filter test system for general air filters (ISO 16890) and extended to fulfil the specifications of ISO 29461.It was developed with the aim of testing filters with different shapes (filter cartridges, cassette filter, filter with filter bags and plane filter media) using varying test aerosols (salt, oil) under adjustable air conditions (air humidity, temperature) within the test duct. By using the test system the following filter characteristics can be determined: differential pressure curves, dust holding capacity, gravimetric efficiency, fractional efficiency, salt removal efficiency (ISO/AWI 29461-4) and water endurance (ISO 29461-2).
Standards
The system complies with:
(1) ISO 29461-1 – Air filter performance, test methods.
(2) ISO 29461-2 – Air filter performance, gas adsorption test.
(3) ISO/AWI 29461-4 – Air filter performance, salt removal efficiency.
(4) ISO 16890-2 – Air filter classification and testing for general air filters.
(5) ISO 16890-3 – Gravimetric efficiency determination.
(6) ISO 16890-4 – Fractional efficiency and dust holding capacity.
(7) ISO/DIS 29461-7 – Gas turbine filter testing guidance.
(8) ISO 12103-1 – Fine test dust (A2) for filter performance.
(9) ASHRAE 52.2 – Air filter testing using airflow and particle size distribution.
(10) EN 779 – Requirements for high-efficiency air filters.
(11) GB/T 12103-1 & GB/T 12103-2 – Test dust and adsorption methods.
(12) GB/T 18801-2015 – Performance testing for air purifiers.
Principle
A defined volume flow rate is sucked through a HEPA intake filter, the attached test duct and the safety filter. The test system is composed of 6 sections: aerosol inlet, upstream measurement, specimen holder, downstream measurement, safety filter and flow rate measurement. The measurement sections are equipped with ports for the aerosol characterization and the determination of the pressure drop.
Features
Circulation mode for control of the test parameters temperature and humidity
Injection of different aerosols (NaCl, KCl, DEHS) into an optimal flow profile
Automated feeding of water droplets and supersaturated vapour
High level of automation, mostly automated test runs with complete operator guiding
Gas-Tight Test Ducts: Ensure accurate particle and gas measurements.
Modular Design: Accommodates different filter types and sizes.
High Automation: Software-driven sequences with automatic data acquisition.
Multi-Medium Testing: Supports various aerosols and pollutant gases.
Standardized Reporting: Automatically generates reports including differential pressure, dust loading, fractional efficiency, and salt removal efficiency.
Environmental Control: Built-in temperature and humidity sensors allow testing under controlled conditions.
Technical data
| Parameter | Unit | Value |
|---|---|---|
| Test flow rate | m³/h | 800 … 11.000 |
| Test aerosol | – | DEHS, KCl, Ashrae, ISO 12103-A2 (AC fine), ISO 12103-A4 (AC coarse) |
| Test specimen dimensions | – | 610 × 610 mm (pocket and cassette filters); diameter ≤ 400 mm, length ≤ 1500 mm (filter cartridges) |
| Differential pressure of test specimen | Pa | max. 2000 |
| Compressed air supply (operating gas/air) | bar | min. 5 (17 m³/h) |
| Water supply (operating medium) | bar | min. 3 |
| Power supply | – | 3 × 400 VAC, 125 A, 50 Hz |
| Air circulation | % | 0 … 100 |
| Sensors (others) | – | Temperature, relative humidity, air pressure |
| System dimensions (W × H × D) | m | 4.6 × 1.7 × 14.0 |
在线联系供应商
Other supplier products
| Automatic Filter Performance Tester G506 Manufacturer | Multi-standard Filtration Efficiency Test System | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Parameters Items Parameter Apll... | |
| Vacuum Blood Collection Tube Suction Volume Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com In the medical field, particularly in processes involving blood sample collection, the accu... | |
| Bottle Wall and Bottom Thickness Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The wall and bottom thickness tester for bottles is mainly used to measure th... | |
| Safety Helmet Chin-strap Strength Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard GB/T 2812-2006: Safety Helmets GB/T 2811-2019: Head Protection – Vocabular... | |
| Bearing Friction Torque Measuring Instrument | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 32562-2016 JJF1137-2024 Main Purposes The bearing friction torque tester... |
Same products
| HDPE高速水冷双壁波纹管生产线 | 卖方: Shandong HUASU Plastic Technology Co.,Ltd. | 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功... | |
| PanEVAP & MVR system | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat... | |
| PanGAP wide gap welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel... | |
| PanBloc welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac... | |
| PanBox welded plate heat exchanger | 卖方: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd | PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated... |