16-Segment Heated Thermal Manikin (Dry Type)
Get a quote:
Whats/App: +86 181 0160 0864
Web: gellowen.co.uk
The 16-Segment Heated Thermal Manikin (Dry Type) is a precision anthropomorphic measurement system designed to simulate human body heat under controlled environmental conditions. By reproducing realistic human surface temperature distribution without breathing or sweating functions, the system provides reliable thermal response data for evaluating clothing insulation, indoor environments, HVAC airflow performance, and protective equipment. It is suitable for laboratory testing, academic research, and engineering verification where stable and repeatable human-equivalent heat output is required.
Application
The 16-Segment Heated Thermal Manikin is used in the following application areas:
(1) Cleanroom airflow evaluation and contamination risk assessment
(2) HVAC research, teaching, and indoor thermal comfort studies
(3) Thermal insulation testing of workwear, protective clothing, and medical garments
(4) Simulation of human heat sources in vehicle interiors, buses, trains, ships, and submarines
(5) Aircraft, spacecraft, and cabin thermal environment studies
(6) Hospital operating room temperature control and patient thermal protection testing
(7) Occupational safety and thermal stress evaluation in controlled environments
Standards
The system is designed and manufactured with reference to the following international and national standards:
(1) ISO 14644-1 / ISO 14644-3 – Cleanrooms and associated controlled environments
(2) DIN 1946-4 – Ventilation and air-conditioning systems in healthcare facilities
(3) ISO 14505-2 – Determination of thermal insulation using a thermal manikin (analogous method)
(4) ASTM F1291 – Thermal insulation of clothing using a heated manikin
(5) EN 14058 – Protective clothing against cool environments (reference testing)
(6) GB/T 18883-2020 – Indoor air quality standard
(7) GB/T 50785-2012 – Cleanroom design and testing for hospitals
(8) GB 50333-2013 – Technical code for hospital HVAC system design
(9) GB/T 4249-2019 – Indoor thermal environment impact on human body
(10) YY/T 0287-2009 – Thermal performance evaluation of medical protective clothing
Parameters
| Component | Technical Parameter |
|---|---|
| Manikin body | 16 independent heating zones (head, torso, arms, legs); glass fiber reinforced resin; standing or sitting posture; customizable Asian or European body shape |
| Heating system | Nickel-chromium heating wires; PT100 B-class sensors; surface temperature 32–37°C (33 ± 0.5°C typical); center temperature 37 ± 0.1°C |
| Zone uniformity | Maximum temperature difference between zones ≤ 1.0°C |
| Control system | 16-segment PID temperature control; 2 × 8-channel boards; automatic PID tuning |
| Control box | 780 × 780 × 260 mm; mobile base with brakes; aircraft-style quick connectors |
| Heat output | 70–100 W per manikin, adjustable |
| Surface material | Smooth, non-particle shedding, suitable for cleanroom use |
| Operating environment | Temperature 10–40°C; humidity 15–95% RH |
| Power supply | AC 220–240 V, 50 Hz |
| Power consumption | Peak ≤ 1200 W; steady-state heat flux 0–300 W/m² |
| Manikin height | Approx. 180 cm (standing posture) |
| Manikin weight | Approx. 45 kg |
| Optional customization | Child or infant manikins; individual body parts; lying posture patient simulation |
在线联系供应商
Other supplier products
| Safety Helmet High Temperature Pre-Treatment Chamber | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The safety helmet high-temperature pre-treatment chamber is manufactured according... | |
| Automated Filter Element Test System | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk Test System for production control of filter elements (e.g. exhaust filter, HEPA f... | |
| Temperature and Humidity Alternating Test Chamber for Automotive Wires | Get a quote: Whats/App: +86 181 0160 0864 TheTemperature and Humidity Alternating Test Chamber for Automotive Wiresis designed to perform cyclic ... | |
| Schopper Abrasion Tester | Standards DIN 53863. Part 2: Abrasion test methods for textile fabrics (rotary abrasion test). GME Standard 60345 & GMW Standard 3283: Indust... | |
| Automatic Reaction Calorimeter | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk This instrument is a professional testing instrument that simulates the specific p... |
Same products
| Gasket for Plate Heat Exchanger | 卖方: Hengshui Hongcan Import and Export Trading Co., Ltd | The sealing gasketin plate heat exchangers primarily serves to seal between hot and cold media. ... | |
| Energy Saver | 卖方: O&K GROUP LIMITED | Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies... | |
| ER1100 Aluminum Welding Wire | 卖方: 868776 | The ER1100 Aluminum Welding Wire from Hangzhou Kunli Welding Materials Co., Ltd. is designed for ... | |
| air conditioner | 卖方: O&K GROUP LIMITED | Looking for Quality Products? From electronics to home essentials, fashion to industrial supplies... | |
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... |