The burning manikin system is used to test the overall thermal protection performance of protective clothing.Complete combustion manikin system, which consists of combustion chamber, burning manikin and gas control system and other components.

Application

The Burning Manikin System is primarily applied in the following areas:

Fire Environment Simulation: This system simulates high-risk fire environments, realistically recreating flashover scenarios. Using a burning manikin testing system and accompanying software, it evaluates the flame-retardant performance of protective clothing.

Thermal Protection Performance Assessment: By placing thermal sensors on the manikin model, it measures and calculates the heat and temperature transmitted through the clothing to various parts of the manikin's surface, thereby predicting the possible locations and extent of burns.

Fire Environment Research: This system helps researchers analyze the heat transfer mechanism between the heat source, clothing, and the human body in a fire environment, improving the thermal protection performance of protective clothing.

Firefighter Protection: Through burning manikin testing, it evaluates the heat insulation performance of fire suits, optimizing designs to reduce the rate of burns.

These applications contribute to improving the survivability of firefighters and soldiers under high-intensity flame conditions.

Standards

EN ISO 11612:rotective clothing - Clothing to protect against heat and flame - Minimum performance requirements

EN ISO 11611:Protective clothing for use in welding and allied processes - Minimum basic safety requirements

ISO 13506:Protective clothing against heat and flame - Test method for complete garments - Prediction of burn injury using an instrumented manikin

EN469:2005:Protective clothing for firefighters - Performance requirements for protective clothing for firefighting

ISO13506-1:Protective clothing against heat and flame- part1: Test method for complete garments-Measurement of transferred energy using an instrumented manikin

ISO13506-2:Protective clothing against heat and flame- part2: Skin burn injury prediction- Calculation requirements and test cases

ASTM F1930:Standard test method for evaluation of flame-resistant clothing for protection against fire simulations using an instrumented manikin

GB8965.1:Protective clothing - Flame retardant protective clothing

Principle

The burning manikin system is composed of:

1. computer combustion dummy;

2. thermal sensor group;

3. flame generator;

4. computer control module;

5. data acquisition and processing module;

6. burn analysis module.

Features

High-precision measurement: Utilizing 124 thermal sensors, it accurately measures changes in human skin temperature to predict burn severity.

Repeatability: Test results can be repeated in simulated fire environments, ensuring accuracy and reliability.

Rapid testing: The system can complete tests quickly, suitable for rapid assessment and quality control.

Versatility: Applicable to various types of protective clothing, such as flame-retardant suits and fire-fighting suits, providing comprehensive thermal protection performance evaluation.

Standardized testing: Complies with international standards such as ISO 13506 and ASTM F1930. ensuring international recognition of test results.

These features make the burning mannequin system of significant value in the field of safety protection, effectively improving the thermal protection performance of protective clothing and ensuring personnel safety.

Parameters

Parameter Description
Dimensions (L×W×H) 14m × 6m × ≥6m
Weight 2000 kg
Thermal Sensors Monitor heat flux changes on mannequin surface; quantity varies by design
Combustion Flame Array Multiple propane generators arranged around mannequin to simulate fire
Gas Supply System Provides stable gas via high-pressure tanks and pipelines
Combustion Chamber Houses flame array and mannequin for safe, controlled experiments
Data Acquisition System Collects data from thermal sensors with processing units and cables
Testing Software Controls experiments, analyzes data, and generates visual reports
Calibration Tools Ensure accuracy and reliability of sensor data through calibration

在线联系供应商

至: Standard Group (Hong Kong) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

PV Module Testing Equipment – UV Aging Test Chamber
PV Module Testing Equipment – UV Aging Test Chamber Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The UV Aging Test Chamber for photovoltaic (PV) modules is designed to simulate lo...
 5th Percentile Female Crash Test Dummy
5th Percentile Female Crash Test Dummy Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The 5th Percentile Female Crash Test Dummy serves as a surrogate for a real human ...
Microbial Barrier Tester
Microbial Barrier Tester Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk Y/T 0471.5-2017 is a newly updated standard, which specifies the experimental meth...
Snap Button Tester | Button Snap Pull Tester
Snap Button Tester | Button Snap Pull Tester Standard ASTM D7142-2/F963: Standard Consumer Safety Specification for Toy Safety CFR 1500: Consumer Product Safety Commission (CPSC) Hazardous S...
Scorch Sublimation Tester | Textile Testing Products
Scorch Sublimation Tester | Textile Testing Products Applications: Scorch/Sublimation Tester is used in the laboratory to evaluate colour fastness to dry heat, hot pressing and sublimation, as well a...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...