The internal pressure resistance tester for glass bottles is a device specifically used to test the internal pressure - resistance performance of glass bottles.
Applications
The internal pressure resistance tester for glass bottles is mainly used to evaluate the ability of glass bottles to withstand pressure under different pressure conditions. Through testing, we can determine whether glass bottles can withstand a certain internal pressure without breaking or deforming during the processes of filling, transportation, and use. This device is widely applied in industries such as beer brewing, pharmaceutical production, and food packaging, and is of great significance for ensuring product quality and consumer safety. In the beer - brewing field, the internal pressure resistance tester for glass bottles is used to inspect the internal pressure - resistance ability of beer bottles and other alcohol - beverage packaging bottles, ensuring that they will not break due to pressure changes during filling, transportation, and use. In the pharmaceutical production process, this device is used to test the internal pressure resistance of pharmaceutical packaging bottles such as antibiotic vials and infusion bottles, safeguarding the stability and safety of drugs during storage and transportation. In addition, in the food - packaging field, various beverage bottles such as carbonated beverage bottles and juice bottles also need to undergo internal pressure - resistance testing using this device.
Standards
The design and manufacture of the internal pressure resistance tester for glass bottles comply with a series of national and international standards to ensure the accuracy and reliability of test results. Among the more common standards are GB/T 4546 - 2008 Test Method for Internal Pressure Resistance of Glass Containers and ISO 7458:2004 Test Method for Internal Pressure Resistance of Glass Containers. These standards specify in detail the test methods for the internal pressure resistance of glass bottles, specimen preparation, test conditions, etc., providing a unified standard for the use of the tester.
Features
• Large color LCD display showing test results, including each measurement and statistical value;
• Touchscreen control, clear and intuitive, easy to operate;
• High-speed processing chip, significantly improving operating speed;
• Adjustable test space, suitable for a wide range of products;
• Capable of constant pressure holding tests, pressurized but not held pressure tests, and burst tests;
• Equipped with a micro printer for quick printing of each measurement result, statistical values, and average values;
• The instrument can store multiple sets of data, with 10 measurements per set;
• Equipped with testing software for unlimited storage and printing;
• No complex hydraulic system, reducing leakage rate and facilitating maintenance;
• The system program has an ISP online upgrade function, providing personalized services.
Technical Parameters
| Technical Parameter | Specification |
|---|---|
| Testing Pressure Range | Usually it can reach 0 - 6MPa or higher (specific range depends on equipment model and testing requirements); covers internal pressure-resistance testing needs of most glass bottles. |
| Display Accuracy | Generally 0.001MPa or higher; enables precise display of pressure changes during the testing process. |
| Pressurizing Medium | Usually water (ensures no additional pressure impact on glass bottles; also convenient for controlling and monitoring pressure changes). |
| Testing Speed | Relatively fast; testing time per bottle ranges from a few seconds to a dozen seconds (depends on equipment model, testing pressure, and specimen specifications); helps improve testing efficiency and productivity. |
| Overall Error | Usually less than 0.5%FS (full-scale error); ensures the accuracy and reliability of test results. |
| Working Environment | Needs to be used in a certain environment: temperature range of 5 - 40℃ (varies by equipment model), relative humidity not exceeding a certain value; helps maintain equipment stability and extend its service life. |
| Safety Performance | Equipped with safety features (e.g., leak-protection control circuits) to ensure operator safety; also has automatic fault detection and common fault prompting functions, facilitating prompt problem identification and resolution. |
在线联系供应商
Other supplier products
| Vacuum leak tester / Vacuum leak instrument | Vacuum Decay Leak Tester specializes in the detection of leaks in ampoules, vials, injection bottles, freeze-dried powder injection bottles, and pr... | |
| PLC liquid crystal touch impact testing machine (simple suspension) | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk A PLC LCD Touch Impact Testing Machine (Simple Suspension) is a type of pendulum i... | |
| Multi-Functional Tribology Tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Multi-Functional Tribology Tester is a high-precision friction and wear testin... | |
| Molten Metal Splash Resistance Tester | Get a quote: Whats/App: +86 181 0160 0864 The Molten Metal Splash Resistance Tester is designed to evaluate the resistance of materials to molten... | |
| PLC liquid crystal touch impact testing machine (simple suspension) | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk A PLC LCD Touch Impact Testing Machine (Simple Suspension) is a type of pendulum i... |
Same products
| Common Rail Injector Valve F00R J02 012 | 卖方: 868983 | Common Rail Injector Valve F00R J02 012 David Chen | |
| Common Rail Injector Valve F00R J02 005 | 卖方: 868983 | Common Rail Injector Valve F00R J02 005 David Chen | |
| Common Rail Injector Valve F00R J01 945 | 卖方: 868983 | Common Rail Injector Valve F00R J01 945 David Chen | |
| Common Rail Injector Valve F00R J01 941 | 卖方: 868983 | Common Rail Injector Valve F00R J01 941 David Chen | |
| Common Rail Injector Valve F00R J01 924 | 卖方: 868983 | Common Rail Injector Valve F00R J01 924 David Chen |