.

Toilet Corrosion Test Chamber (HCl and Ammonia)

Get a quote:

Whats/App: +86 181 0160 0864

Web: gellowen.co.uk

The Toilet Corrosion Test Chamber (HCl and Ammonia) is used to evaluate the rust resistance of toilet products to detergents and urine, meeting the corrosion testing requirements of GB/T 4706.53-2024 and IEC 60335-2-84:2019 standards. This equipment simulates an ammonia and hydrochloric acid environment to conduct a 96-hour corrosion test on the toilet, ensuring its continued normal operation under harsh conditions. Key technical parameters include test chamber dimensions, temperature, and gas concentration, and it is equipped with appropriate safety and sealing measures.

Applications

Toilet seat hydrochloric acid and ammonia corrosion tester is used for testing to evaluate the ability of toilet seat products to provide adequate rust protection against detergents and urine. The test chamber by simulating ammonia components, hydrochloric acid solvent body, medium on the toilet electrical components or other inorganic cover layer in condensation conditions of corrosion test. The test chamber is electronic toilet sampling and testing of product quality supervision and inspection institute 3 testing organizations and toilet manufacturers of essential test equipment.

Standards

GB/T 4706.53-2024: Safety of household and similar electrical appliances - Part 2: Particular requirements for commercial dishwashing machines, glass-washing machines and utensil-washing machines

IEC 60335-2-84:2019: Household and similar electrical appliances - Safety - Part 2-84: Particular requirements for commercial dishwashing machines, glass-washing machines and utensil-washing machines

Features

1. Precise and Controllable Corrosive Environment: It can stably maintain specific concentrations of ammonia (0.055%±0.005%) and hydrochloric acid (0.0005%±0.0002%), using a gas cylinder method for gas generation and a corrosion-resistant mass flow meter for flow control, ensuring precise matching of the corrosive medium concentration and flow rate to test requirements.

2. Standardized Test Conditions: It requires operation in a cleanroom environment without strong airflow. Temperature (25℃±2℃) and humidity (<75% RH) are strictly controlled to ensure the repeatability and reliability of test results.

3. Strong Sample Load Capacity Adaptability: The equipped sample test rack has a maximum load capacity of ≥50kg and can maintain a vertical placement at 90°±2°, adapting to the fixing requirements of large items such as toilet seats.

4. Reasonable structural dimensions: The inner casing (W1200×H1200×D1200mm) is large enough to accommodate a toilet, while the outer casing (approximately W2350×H1700×D1500mm) balances operating space with equipment integration.

5. Low operating energy consumption: The installed power is only 400W, and it is compatible with AC 220V universal power supplies, resulting in high cost and environmental adaptability.

Technical Parameters

No.Main ParametersSpecifications
1 Inner box size W1200×H1200×D1200mm
2 Outer box size About W2350×H1700×D1500mm
3 Test temperature Room temperature
4 Ammonia concentration 0.055%±0.005
5 Hydrochloric acid concentration 0.0005%±0.0002
6 Test gas generation method Cylinder method
7 Test gas control Calculate by volume ratio (per test requirements), then control flow rate via anticorrosive mass flow meter
8 Sample test frame Maximum load ≥50kg; placed vertically at 90°±2°
9 Use environment & temperature Clean room (no strong airflow); temperature 25℃±2℃
10 Use environmental humidity <75% RH
11 Equipment power supply AC 220V 50/60Hz
12 Installed power 400W

在线联系供应商

至: Standard Group (Hong Kong) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Xenon Test Chamber/weather ometer
Xenon Test Chamber/weather ometer IntroductionWeather-Ometer and Fade-Ometer tester adopts water-cooled xenon lamp. This instrument using argon arc lamp simulation control ideal nat...
Spinneret Inspection Microscope
Spinneret Inspection Microscope Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk ① Mechanical Components Overview 1. This machine employs an X-Y-Z three-axis moti...
Rail transit car wire abrasion testing machine
Rail transit car wire abrasion testing machine Get a quote: Whats/App: +86 181 0160 0864 The Rail Transit Car Wire Abrasion Testing Machine is designed to evaluate the abrasion resistance of w...
Steiner Tunnel Test Furnace
Steiner Tunnel Test Furnace Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The ASTM E84 Building Materials Flame Spread Test Apparatus is designed to evaluat...
Shoe Insulation Tester | Thermal Performance Test
Shoe Insulation Tester | Thermal Performance Test Application: Shoes Heat Insulation Tester is used to test shoe heat insulation / thermal insulation against hot performance. Place the shoe in san...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...