High Temperature Creep Testing Equipment ISO 204
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
(1) Tensile creep and endurance testing of metallic materials at elevated temperatures.
(2) Long-term creep testing of non-metallic and composite materials under constant load.
(3) Material performance evaluation for aerospace structural components.
(4) High-temperature durability testing for automotive and mechanical parts.
(5) Material research and verification in metallurgical and petrochemical industries.
(6) Academic research and teaching in universities and research institutes.
(7) Quality inspection and certification testing in industrial laboratories.
Standards
(1) ASTM E139 — Standard Test Methods for Conducting Creep, Creep-Rupture, and Stress-Rupture Tests of Metallic Materials
(2) ASTM E292 — Standard Guide for Selection and Installation of Materials for Creep Testing
(3) ASTM D1654 — Standard Test Method for Evaluation of Painted or Coated Specimens Subjected to Corrosive Environments
(4) ASTM C1291 — Standard Test Method for Creep of Ceramic Materials in Compression
(5) ASTM C1337 — Standard Test Method for Creep of Advanced Ceramics in Tension
(6) ASTM D2990 — Standard Test Methods for Tensile, Compressive, and Flexural Creep and Creep-Rupture of Plastics
(7) ASTM D3039 — Standard Test Method for Tensile Properties of Polymer Matrix Composite Materials
(8) ASTM D7337 — Standard Test Method for Compressive Creep of Plastics
(9) ASTM F519 — Standard Test Method for Mechanical Hydrogen Embrittlement Evaluation
(10) BS EN 2002-5 — Aerospace series — Metallic materials — Tensile testing at elevated temperature
(11) BS ISO 8013 — Aerospace — Metallic materials — Tensile testing at elevated temperature
(12) BS 4A4-1 — Aerospace series — Test methods for metallic materials
(13) BS EN ISO 204 — Metallic materials — Uniaxial creep testing in tension
(14) BS EN ISO 899-1 — Plastics — Determination of creep behavior
(15) ISO 903 — Plastics — Determination of creep behavior in tension
(16) MIL-STD-1312 — Fastener Test Methods
(17) NASM 1312 — Aerospace fastener test methods
Features
(1) High-precision constant-load creep testing under elevated temperature conditions.
(2) Knife-edge lever bearing structure providing high sensitivity and stability.
(3) Electric loading system with manual fine adjustment capability.
(4) Automatic leveling system controlled by photoelectric sensors.
(5) Manual leveling function ensuring test stability during power interruption.
(6) Fracture protection mechanism using oil buffering to prevent sudden weight drop.
(7) High-temperature alloy fixtures ensuring long service life and dimensional stability.
(8) Digital PID temperature control ensuring uniform and stable furnace temperature.
(9) Computer-based creep control and long-term testing software with multi-machine monitoring.
Parameters
Host Machine
| Item | Specification |
|---|---|
| Maximum testing force | 50 kN |
| Testing accuracy class | 0.5 |
| Force measurement range | 0.4% – 100% FS |
| Force measurement error | ±0.5% |
| Force resolution | 1 / 300000 |
| Coaxiality | ≤10% |
| Deformation measurement error | ±0.002 mm |
| Pulling rod maximum stroke | ≥150 mm |
| Pulling rod speed | 0.01 – 50 mm/min |
| Deformation measurement range | 0 – 10 mm |
| Extensometer resolution | 0.001 mm |
| Extensometer measuring error | ≤2 μm |
| Communication interface | Ethernet (TCP/IP) |
| Power supply | AC 220 V, 50 Hz, 1 kW |
| Host machine weight | 600 kg |
High Temperature Furnace
| Item | Specification |
|---|---|
| Furnace structure | Split three-stage electric heating |
| Furnace body material | Stainless steel 304 |
| Thermal insulation | Ceramic fiber cotton |
| Heating wire diameter | φ1.2 mm |
| Working temperature range | 300 – 1100 ℃ |
| Uniform temperature zone length | ≥150 mm |
| Hearth size | φ80 × 320 mm |
| Temperature fluctuation | ≤ ±2 ℃ |
| Temperature gradient | ≤3 ℃ |
| Furnace shell temperature | ≤90 ℃ |
| Temperature controller accuracy | Class 0.1 |
| Power supply | AC 380 V, 50 Hz, 3 kW |
Accessories
(1) High-temperature tensile fixtures with upper and lower grips.
(2) High-temperature rod and water-cooled rod assembly (φ10 standard specimen).
(3) Electric furnace suspension and hanging mechanism.
(4) High-temperature specimen extraction device for φ10 samples.
(5) Two high-precision deformation measurement sensors.
(6) Digital PID temperature controller.
在线联系供应商
Other supplier products
| STD Blowing Sand and Dust Test Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Features and Benefits 1. Custom systems, the size and performance can be customized accord... | |
| Goggles Puncture Resistance Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applicable standards: GB 811-2010 ECE R22.05 EN1077 Purpose It is to make a certain ... | |
| Helmet Wearing Height Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Main Purposes Measure the wearing height of helmets to ensure the accuracy and safety of h... | |
| ASTM E84 Steiner Tunnel Test Furnace | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The ASTM E84 Building Materials Flame Spread Test Apparatus is designed to ev... | |
| Textile wet adhesion performance testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is widely used in: (1) Apparel and Fashion Textiles – Assess... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |