Smoldering Performance Test Furnace, Thermal Insulation Material Tester, ASTM E1352 Fire Test Equipment Manufacturer

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

E-mail:info@standard-groups。com

Features

1. We have a strong after-sales service team.

2. We can promptly and efficiently handle various issues, relieving customers of any concerns.

3. We have a complete inventory of spare parts, eliminating the hassle of long lead times for ordering parts.

4. We keep up with industry standard updates and provide testing instruments that meet the latest standards in a timely manner.

Parameters

ParameterDetails
Ambient Temperature 20℃ —— 40℃
Voltage 220V ± 10V, 50HZ, Power 2500W
Weight 35kg
Data Acquisition Interval < 2s
Heating Rate 5℃/min
Test Time 24h
Test Temperature Room Temperature —— 400℃
Thermocouple K-type Armored Thermocouple
Temperature Measurement Range (0 —— 1000)℃

Test Procedures

Sample Preparation: Prepare cubic samples of the insulation material with dimensions of (100 × 100 × 100) mm³. If the material thickness is less than 100 mm, use a stacking method for preparation, ensuring that the temperature-measuring thermocouple is not located at a joint.

Equipment Preheating: Start the test furnace and adjust the heating power to stabilize the average furnace temperature at (750 ± 5) °C for at least 10 minutes. During this period, the temperature drift should not exceed 2 °C, and the maximum deviation from the average temperature should not exceed 10 °C.

Sample Installation: Place the sample in the sample holder, ensuring the central thermocouple is accurately positioned. Then, quickly (within 5 seconds) suspend the sample holder in the designated position inside the furnace.

Test Start: Close the furnace door, start the timer, and record the temperature measured by the thermocouple inside the furnace. Simultaneously monitor the surface and center temperatures of the sample (if required).

Test Monitoring: Continuously observe the sample's condition, recording temperature changes and any abnormal phenomena during the test.

Test Termination: The test duration is 24 hours, or the test can be terminated early when the furnace temperature reaches final equilibrium (temperature drift not exceeding 2 °C within 10 minutes). If equilibrium is not reached after 60 minutes, the test should also be terminated.

Result Judgment: Within the 24-hour test period, if the sample's center temperature does not exceed 600 °C, it is judged as qualified; if it exceeds 600 °C, it is judged as unqualified.

Equipment Cleaning: After the test, remove the sample holder, clean any residue from the furnace, and turn off the equipment power.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Autocatalytic Decomposition Temperature Tester with Thermal Insulation,autocatalytic decomposition temperature measurement
Autocatalytic Decomposition Temperature Tester with Thermal Insulation,autocatalytic decomposition temperature measurement Whats/App: +86 156 1874 6768 Web: standard-groups.com The Autocatalytic Decomposition Temperature Tester with Thermal Insulation (Adiabatic SADT ...
True Body Weight Ingress Egress Tester,Car seat simulates Ingress/Egress tester
True Body Weight Ingress Egress Tester,Car seat simulates Ingress/Egress tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The True Body Weight Ingress/Egress Tester is a specialized machine designed to evaluate ei...
Intramedullary Nails/Bone Screw Static Torque Testing Machine
Intramedullary Nails/Bone Screw Static Torque Testing Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard YY/T 0591-2011: Chinese standard specifying torsion testing methods for intramedu...
ASTM D2843 Smoke Density Testing for Cables
ASTM D2843 Smoke Density Testing for Cables Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The STD AOTSI-NBS smoke density test chamber, from NIST (NBS's predecessor), ...
Smoke Toxicity Test Equipment (Squirrel Cage Method),combustion smoke toxicity analyzer squirrel cage
Smoke Toxicity Test Equipment (Squirrel Cage Method),combustion smoke toxicity analyzer squirrel cage Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The apparatus is widely applied in fire safety research, material performance ...
供应产品

Same products

ER4047 Aluminum Mig Welding Wire
ER4047 Aluminum Mig Welding Wire 卖方: 868776 Hangzhou Kunli Welding Materials Co., Ltd. specializes in manufacturing reliable welding material...
ER4043 Silicon Aluminum Welding Wire
ER4043 Silicon Aluminum Welding Wire 卖方: 868776 Hangzhou Kunli Welding Materials Co., Ltd. specializes in manufacturing high-quality welding mate...
Choosing the Right Equipment for Heavy-Duty Cleaning
Choosing the Right Equipment for Heavy-Duty Cleaning 卖方: Taizhou Feike Mechanical Technology Co., Ltd. FEIKE’s High Pressure Washer is designed for industrial cleaning, equipment maintenance, ve...
ER4043 Silicon Aluminum Welding Wire
ER4043 Silicon Aluminum Welding Wire 卖方: 868776 Hangzhou Kunli Welding Materials Co., Ltd. offers ER4043 Silicon Aluminum Welding Wire for alumin...
HDPE高速水冷双壁波纹管生产线
HDPE高速水冷双壁波纹管生产线 卖方: Shandong HUASU Plastic Technology Co.,Ltd. 机头模具采用双流道结构、氮化磨光处理机头,偏壁调整方便快捷,保证内外层壁厚均匀和稳定成型。 最新设计密闭压力水冷冷却结构,冷却充分,多点分布真空系统,效率更高,生产速度更快。 双层在线扩口功...