Parameters
| Item | Specification |
|---|---|
| Radiant Panel Radiation Surface | 600 mm × 600 mm |
| Wood Crib Fire Gas Combustion Device | 1 set |
| Test Specimen Rack Angle | Adjustable, 0–50° |
| Air Duct Material | SUS304 stainless steel |
| Air Duct Thickness | 2 mm |
| Fan Airflow Capacity | Max. 250 m³/min |
| Fan Power | 5.5 kW |
| Fan Frequency Control | 3-phase 380 V, 5.5 kW |
| Air Duct Adjustable Angle | 0–35° |
| Impeller Anemometer | 3 units |
| Wind Speed Accuracy | 0.1 m/s |
Features
Frame-type structure for combustion and specimen holding systems, providing high mechanical stability.
Independent control cabinet and gas supply cabinet design, facilitating laboratory layout and improving operational safety.
Supplied with a compact stainless steel tube burner for wood shavings combustion tests.
Burner equipped with a silicon nitride igniter and UV flame detector, ensuring reliable ignition and real-time flame monitoring to prevent gas leakage.
Imported high-precision rotameter and branded pressure gauges for accurate control of fuel gas flow, combined with solenoid valves for automatic gas shutoff at the end of tests.
Specimen support frame constructed from welded metal square tubes and angle steel, ensuring rigidity during testing.
Adjustable specimen inclination angle using pneumatic actuation, allowing convenient push-button operation.
Fine honeycomb grille installed in the upper air duct and coarse honeycomb grille at the outlet to stabilize airflow.
Air duct angle adjustment driven by a ball screw and servo motor, enabling automatic and precise positioning.
Computer and dedicated software control the entire test process, ensuring convenient operation and reliable safety management.
Accessories
(1) Radiant panel assembly
(2) Wood crib fire gas combustion device
(3) Stainless steel tube burner
(4) Specimen support rack
(5) Air duct system with adjustable angle
(6) Centrifugal fan and frequency control unit
(7) Impeller-type anemometers
(8) Control cabinet and gas supply cabinet
(9) Computer and professional test software
Test Procedures
Specimen Installation
Mount the photovoltaic module or roofing specimen securely on the adjustable test rack and set the required inclination angle.
System Configuration
Adjust the air duct angle and configure the fan speed according to the selected test method and standard requirements.
Ignition and Heating
Activate the radiant panel and combustion system. For applicable tests, ignite the wood crib or burner using the silicon nitride igniter.
Fire Exposure Simulation
Expose the specimen to controlled thermal radiation and wind conditions to simulate external fire scenarios as defined in the selected method.
Monitoring and Recording
Monitor airflow velocity using the impeller anemometers and observe the combustion behavior of the specimen throughout the test.
Test Completion
After the test cycle is completed, the system automatically cuts off the gas supply and records test data for further evaluation.
在线联系供应商
Other supplier products
| Battery Adiabatic Calorimeter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Reference Standards GB/T 36276 - 2023 *Lithium - ion Batteries for Electric Power Energy S... | |
| Micro Controll High-temperature Friction Test device | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applicable Standards When conducting tests, the microcomputer - controlled high - temperat... | |
| UV Curing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Description UV is the ultraviolet (Ultra-VioletRay) English abbreviation. Industrial UV wa... | |
| EN sole bending tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The EN Sole Bending Tester is designed to assess the bending resistance and zigzag durabili... | |
| Safety Helmet Roll-off Testing Equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Purpose Apply an initial load of a certain force to the rear of the helmet. Then, let a we... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |