High Speed 3d & 2.5d Scanning System 14mm
The 2.5D&3D system has the function of conventional 2D galvanometer, and a zoom module is added on the basis of the conventional galvanometer, which solves the problem that the traditional laser scanning galvanometercan only realize plane scanning and small range scanning, and can complete laser processing system applications requiring dynamic zoom. Mainly used in glass drilling, 3D curved marking, welding, laser digging groove, step surface marking and so on. At the same time, this galvo headhas the characteristics of high precision, high stability and support for function customization.
Key Features Of High Speed 3d & 2.5d Scanning System 14mm
Using 14mm 2D galvanometer and VCM-Z reflection z-axis focusing system, X, Y, Z-axis dynamic response perfectly matching, realizing high-speed 3D processing
UV, green and infrared three bands available
High speed glass drilling applications with front focusing field mirror
Optional 14mm UltraScan and Extrascan galvanometers are available according to customer's different accuracy and speed requirements.
Specifications Of High Speed 3d & 2.5d Scanning System 14mm
|
ltem |
Unit |
Parameter |
||||||||
|
Power Supply |
Input Voltage |
vac |
170-264 |
|||||||
|
Output Voltage |
vdc |
±15 |
||||||||
|
Current |
a |
10 |
||||||||
|
Control Card |
Input Interface |
XY2-100 |
||||||||
|
Output Interface |
Entermet Port |
|||||||||
|
Laser Type |
Ultraviolet、IR、Green |
|||||||||
|
EnvironmentalRequirement |
Ambient Temperature |
℃ |
0~+40 |
|||||||
|
Storage Temperature |
℃ |
一10~+60 |
||||||||
|
Humidity |
≤75% Non-Condensing |
|||||||||
|
SpecificationsForDefiectionUnit |
Scan angle |
° |
±11.5 |
|||||||
|
Repeatability |
urad |
5 |
||||||||
|
ppm/K |
12 |
|||||||||
|
urad/K |
30 |
|||||||||
|
Long-Term Driff Over 8h |
mrad |
|||||||||
|
Maximal Processing Speed |
s |
650 |
||||||||
|
Small Step Response |
ms |
≤0.18 |
||||||||
|
Dynamic zoom system parameters |
Small Step Response |
ms |
≤1.6 |
|||||||
|
SpecificationsForOptics |
Laser |
UV Laser |
YAG/Fiber |
Green |
||||||
|
Wavelenth |
nm |
355 |
1064 |
532 |
||||||
|
Coating |
Anti-Reflection Film |
|||||||||
|
Aperture Size |
mm |
φ14 |
||||||||
|
System Input Laser Beam |
mm |
9 |
7 |
|||||||
|
SpecificationsFor Structure |
Weight |
Kg |
8 |
|||||||
|
Dimension(L×W×H) |
mm |
|||||||||
|
3D systemField Size&Spot Diameter |
Ultraviolet |
Field Size |
mm |
100x100x40 |
200x200x80 |
300x300x150 |
400x400x150 |
500x500x150 |
600x600x150 |
|
|
The Smallest Spot diameter1/e² |
mm |
|||||||||
|
IR |
Field Size |
mm |
60x60x60 |
100x100x90 |
100x100x40 |
200x200x80 |
||||
|
The Smallest Spot Diameter1/e² |
mm |
|||||||||
|
Green |
Field Size |
mm |
100x100x40 |
200x200x80 |
300x300x150 |
400x400x150 |
500x500x150 |
600x600x150 |
||
|
The Smallest Spot diameter1/e² |
mm |
|
||||||||
|
Green 2.5D System |
Wavelength |
nm |
532nm |
|||||||
|
Aperture Size |
mm |
φ14 |
||||||||
|
System Input Laser Beam |
mm |
φ3.5 |
||||||||
|
Field Size |
mm |
70x70 |
||||||||
|
Focus Range In Z-Direction |
mm |
±5mm |
||||||||
|
Distance Of F-Theta From Working Face |
mm |
|||||||||
|
The Smallest Spot diameter1/e² |
mm |
|||||||||
|
Application Industry |
Glass Panel Cutting&Driling |
|||||||||
|
Machining Efficiency |
3mm Thick Glass,with Aperture Of 4.6mm, Cutting Time≤15s |
|||||||||
|
IR 2.5D System |
Wavelength |
nm |
1064nm |
|||||||
|
Aperture Size |
φ14 |
|||||||||
|
System Input Laser Beam |
7mm |
|||||||||
|
Field Size |
mm |
210*210 |
||||||||
|
Focus Range In Z-Direction |
mm |
±20mm |
||||||||
|
Distance Of F-Theta From Working Face |
mm |
330mm |
||||||||
|
The Smallest Spot Diameter1/e² |
um |
45 |
||||||||
Hansscannerindependent research and development of a series of scanning head systems (7mm, 8.5mm, 10mm, 14mm, 20mm, 30mm, 50mm), with high precision, high speed, high energy, low temperature drift, strong anti-interference ability and other performance, It is widely used in flight marking, precision marking, precision cutting, precision welding, 3D printing, laser drilling, medical cosmetology and ophthalmic imaging and other industries.
在线联系供应商
Other supplier products
| Ultra-galvo Scanner | The xy galvanometerscanner laser using photoelectric sensor as feedback system is characterized by high repetition accuracy and linearity, and high... | |
| Laser Lens | Common Fθ lens is a series of general lens used in laserfields. The common F-theta lens has developed into the 3th generation product after e... | |
| Ultra-galvo Scanner | The galvanometer scanner laserusing photoelectric sensor as feedback system is characterized by high repetition accuracy and linearity, and high co... | |
| 3-axis Galvo Scan Head | The large-format 3D laser scanner headis free of the processing range limits of 2D field lenses, and can be flexibly selected 100x100mm-2000x2000mm... | |
| VCM G2 | VCM G2 adopts full digital laser galvanometer driver, digital driver board of basic FPGA, stable performance, not easy to be disturbed, flexible to... |