Ventilation
Our Ventilation series products include energy recovery ventilator(ERV), heat recovery ventilator(HRV) and some single ventilator (without heat recovery core). As for HRV and ERV, its function are not only as common exhausting fan but also a fresh air ventilation system. It helps to exhaust stale, damp indoor air and supply fresh, filtered air from outside, thus ensuring optimal indoor air quality and comfortable living. And the two air streams "meet" in the air-to-air exchanger core, the fresh air will be pre-cooled or pre-warmed by the stale air, thus saving your energy bills significantly. The systems are suitable for both retrofit and new construction project.
As for the single ventilator (without heat recovery core), we have uniflow ventilator which brings in fresh air from outside. There are filters and heater inside to make the fresh air clean and warm. We also have balanced ventilation without exchanger core. Just for exhausting the stale air and bringing in fresh air at the same time.
Residential Ceiling ERV/HRV With ESP System-AF Series
Constant fresh air in your home is an important aspect to maintain the indoor air quality. A good ventilation system will protect your family from unpleasant odos and harmful contaminants such as formaldehyde and VOCs. Opening window is a simply way to increase ventilation, it can make your air feel less stuffy, but pollen and other allergens will be invited into your home at the same time.
Thenow residential ceiling mounted energy recovery ventilator (ERV)-ESP System AF Series, different from traditional physical filtration, adopt its patented Pure ESP sterilization system with bacterial killing efficiency up to 99.99% and particles filtration fineness small to 0.001 micron. Thenow energy recovery ventilator ESP system, will exchange stale polluted air with fresh and clean outdoor air without wasting energy.
Features of Residential Ceiling ERV With ESP System-AF Series
Innovative high efficiency counter flow full heat exchanger
Four-layers filtration
Patented Pure ESP sterilization system filter the air without producing ozone
High efficiency DC motor, low noise
Bypass is optional
Pre heating is optional
CO2 , VOC, PM2.5 and humidity sensors are optional
Sensible heat recovery unit is optional
Application of Home Fresh Air Ventilation System With ESP System-AF Series:
Residential building, Hospital, Offices and shops, Kindergarten, Schools, Hotels, Villa etc.
Technical Datas of Residential Fresh Air Exchanger With ESP System-AF Series
Residential Ceiling ERV/HRV With HEPA System-AG Series
Thenowresidential ceiling mounted energy recovery ventilator-HEPA Series added HEPA filters after G3 or F7 filter which can prevent the fine particles high efficiently. We have a completely range of energy recovery ventilation systems offering different levels of air flows and filters to adapt to different HVAC systems.
Features of Residential Energy Recovery Ventilator With HEPA System-AG Series
Innovative high efficiency counter flow full heat exchanger
Two types available: G3 filter + HEPA filter and G3 filter + F7 filter + HEPA filter
218mm Ultra-thin design, save your space
High efficiency DC motor, low noise
Bypass is optional
Pre heating is optional
CO2 , VOC, PM2.5 and humidity sensors are optional
Sensible heat recovery unit is optional
Application of Residential Air Exchanger System With HEPA System-AG Series:
Residential building, Hospital, Offices and shops, Kindergarten, Schools, Hotels, Villa etc.
Technical Datas of Residential Ventilation Systems With HEPA System-AG Series
Model |
Voltage |
Rated Power(W) |
Air Flow (m³/h) |
Enthalpy Efficiency(%) |
Outlet Total Pressure(Pa) |
Noise dB(A) |
Weight (kg) |
Size (LxWxT mm) |
H |
H |
H |
H |
H |
||||
TSX150-AG01 |
220V 50Hz 1PH |
95 |
150 |
66 |
80 |
37 |
22 |
936x640x205 |
TSX250-AG02 |
220V 50Hz 1PH |
110 |
250 |
64 |
95 |
40 |
23 |
955x640x220 |
TSX350-AG01 |
220V 50Hz 1PH |
176 |
350 |
63 |
100 |
43 |
26 |
960x702x260 |
TSX250-AG01 |
220V 50Hz 1PH |
78 |
250 |
74 |
100 |
38 |
31 |
1175x686x218 |
TSX300-AG01 |
220V 50Hz 1PH |
98 |
300 |
72 |
110 |
41 |
34 |
1245x815x218 |
TSX500-AG01 |
220V 50Hz 1PH |
180 |
500 |
72 |
140 |
45 |
49 |
1230x1150x312 |
As one of heat recovery ventilator manufacturersand energy recovery ventilator manufacturers,we have types of related products for sale, if you have needs, please contact us.
在线联系供应商
Other supplier products
Commercial Ceiling Mounted ERV/HRV HEPA System-AG Series | Thenow light commercial ceiling mounted energy recovery ventilator -HEPA Series can be used in various applications, such as hospitals, labs and ot... | |
Wine Cellar Cooling System | Wine Cellar Cooling System As we all know, split wine cellar cooling systemis an extremely important part of any wine cellar design, especially ke... | |
Commercial Ceiling Mounted ERV/HRV-AQ Series | Thenow commercial ceiling mounted ervenergy recovery ventilator -AQ Series, different with HEPA series, it was designed without HEPA and medium fil... | |
Residential ERV/HRV | Residential ERV/HRV is whole house ventilation with heat recovery. You can also call it whole home air exchangeror whole house fresh air system. C... | |
Ventilation | Our Ventilation series products include energy recovery ventilator(ERV), heat recovery ventilator(HRV) and some single ventilator (without heat rec... |