Circular Stapler
Uses of Circular Stapler
Instruction for Use
The Single Use circular bowel staplerplaces a circular, double staggered row of titanium staples when it is activated. Immediately after staple formation, the circular knife blade resects the excess tissue and creates a circular anastomosis.
Do not use the Single Use eea surgical stapleron any tissue that will be compressed to less than
1mm in thickness as the staples will not be tight enough to ensure hemostasis.
Do not use the disposable circular stapler on any tissue which cannot be compressed comfortably to 2.0mm for 21 mm and 23mm, 2.3mm for 25mm and 27mm, 2.5mm for 29mm, eea 31 staplerand 33mm in thickness. Overly thick inverted tissue could be crushed when the instrument is closed. Failure to do it may result in poor heeding, or narrowing of the anastomosis.
The Single Use surgical circular stapler should not be used if the instrument is too large for the diameter of the structure, which could be stretched or thinned out by introducing the instrument. Failure to that leakage and narrowing of the anastomosis could occur.
Do not use the Single Use surgical circular stapler unless sufficient tissue presents and allows proper inversion of tissue edges, so that staples may be placed securely.
Do not use the Single Use Circular Stapler unless adequacy of hemostasis can be visually verified after firing.
Circular Stapler Features & Benefits
One-piece anvil provide strong support
Ensure the “B” shape formation
Easy to be placed into purse-string
Variable speed tail
Protect stomas while removing stapler, uniformly squeeze tissue when closing.
Single edged circular knife
Ensure sharper cutting
Indicated window design Tissue compression scale
Fire until the indicators within the green zone, ensure the safe suture.
Patented clamping slot design
Ensure better connection and smooth placement, reduces the damage when placing into the tissue.
Circular Stapler Model & Specification
Disposable Circular Stapler |
||||||
Figure |
Item Code |
Outer Dia |
Inner Dia |
Staple Qty |
Staple Height |
Staple Formation Height |
(E)SCS21 |
21mm |
13mm |
18 |
|||
SCSA21 |
21mm |
13mm |
18 |
|||
(E)SCS23 |
23mm |
15mm |
20 |
|||
SCSA23 |
23mm |
15mm |
20 |
|||
(E)SCS25 |
25mm |
17mm |
22 |
|||
SCSA25 |
25mm |
17mm |
22 |
|||
(E)SCS27 |
27mm |
19mm |
24 |
|||
SCSA27 |
27mm |
19mm |
24 |
|||
(E)SCS29 |
29mm |
21mm |
26 |
|||
SCSA29 |
29mm |
21mm |
26 |
|||
(E)SCS31 |
31mm |
23mm |
28 |
|||
SCSA31 |
31mm |
23mm |
28 |
|||
(E)SCS33 |
33mm |
25mm |
32 |
|||
SCSA33 |
33mm |
25mm |
32 |
If you are interested and want to know circular stapler price, please contact us!
As one of the most professionalsurgery equipment manufacturers, we provide laparoscopic suction cannula, eea stapling device, cea stapler, laparoscopic circular stapler, anvil eea stapler, circular stapler anvil, laparoscopic instrumentsand etc. Want to know more, contact us.
在线联系供应商
Other supplier products
Endoscopic Linear Cutter Stapler | ①. Don't use in aorta. ②. Don't use in blood-starved or necrotic tissue . ③. Don't re-use. Endoscopic Linear Cutter StaplerFeatures & Benefi... | |
Endoscopic Retriever Bag | ①The single use endo retrieval bagis not intended for use when endoscopic techniques are contraindicated. ②The single use endo retrieval bag is n... | |
Endoscopic Retriever Bag | Usage of Endoscopic Retriever Bag Instruction for Use The single use endopouch retrieval bagis not intended for use when endoscopic techniques ... | |
TRI-STAPLE TECHNOLOGY | Tri-Staple technologyreloads with its stepped cartridge face, delivers graduated compression, optimizing the interaction between the tissue and sta... | |
Circular Stapler | Uses of Circular Stapler Instruction for Use The Single Use circular bowel staplerplaces a circular, double staggered row of titanium staples whe... |
Same products
Fluke 15B+ 17B+ 18B+ 数字万用表电压频率测试仪 | 卖方: 深圳市维客修科技有限公司 | iFixes 10CC半透明/全透明/乳白色/浅无铅助焊膏适用于手机主板CPU BGA维修。iFixes助焊剂注射器注射焊膏焊接膏手机整理焊接耗材系列,适用于电路板纳米芯片,手机PCB, SMT... | |
Grey Rubber Stopper For Blood Collection Tube | 卖方: Taizhou KangLong Medical Treatment Technology Co., Ltd. | Medical Grey Rubber Stopper For Blood Collection Tube Good formulation technology guarantees... | |
HTT-02 Hot Tack Tester | 卖方: Cell Instruments Co., Ltd | The HTT-02 Hot Tack Testeris specifically designed to assess this property by measuring the stren... | |
SPC-01 Stretch Film Peeling Cling Tester | 卖方: Cell Instruments Co., Ltd | The SPC-01 Stretch Film Peeling Cling Testermeasures the adhesion between two layers of stretch f... | |
FTT-01 Film Thickness Tester | 卖方: Cell Instruments Co., Ltd | The FTT-01 FilmThickness Testerutilizes a mechanical scanning technique to measure the thickness ... |