Polypectomy Snares (Hot)
This device indicated for use endoscopically for the removal of polyps.
Features of Hot PolypectomySnares (Hot)
Snares are available in multiple shapes, stiffness ranging from 'soft' to 'Hard', as well as full range snare open width to meet different polyps cutting requirement.
Braided wires for excellent coagulation and bleeding control.
360° 1:1 rotation for precise adjustment.
Specification of Snare Polyp(Hot)
Rgeular items
|
REF |
Catheter |
Snare |
Stiffness |
Units/Box |
|||
|
Fixed |
Rotatable |
Catheter Diam. (mm) |
Working length (mm) |
Opening Width (mm) |
Configuration |
||
|
L16CA241815A0 |
L16RA241815A0 |
1800 |
15 |
Oval |
Soft |
10 |
|
|
L16CA241825A0 |
L16RA241825A0 |
1800 |
25 |
||||
|
L16CA241832A0 |
L16RA241832A0 |
1800 |
32 |
||||
|
L16CA242415A0 |
L16RA242415A0 |
2400 |
15 |
||||
|
L16CA242425A0 |
L16RA242425A0 |
2400 |
25 |
||||
|
L16CA242432A0 |
L16RA242432A0 |
2400 |
32 |
||||
|
L16CB241822A0 |
L16RB241822A0 |
1800 |
22 |
Hexagon |
|||
|
L16CB241832A0 |
L16RB241832A0 |
1800 |
32 |
||||
|
L16CB242422A0 |
L16RB242422A0 |
2400 |
22 |
||||
|
L16CB242432A0 |
L16RB242432A0 |
2400 |
32 |
||||
|
L16CC241825A0 |
L16RC241825A0 |
1800 |
25 |
Half Moon |
|||
|
L16CC241832A0 |
L16RC241832A0 |
1800 |
32 |
||||
|
L16CC242425A0 |
L16RC242425A0 |
2400 |
25 |
||||
|
L16CC242432A0 |
L16RC242432A0 |
2400 |
32 |
||||
|
L16CA241815B0 |
L16RA241815B0 |
1800 |
15 |
Oval |
Hard |
||
|
L16CA241825B0 |
L16RA241825B0 |
1800 |
25 |
||||
|
L16CA241832B0 |
L16RA241832B0 |
1800 |
32 |
||||
|
L16CA242415B0 |
L16RA242415B0 |
2400 |
15 |
||||
|
L16CA242425B0 |
L16RA242425B0 |
2400 |
25 |
||||
|
L16CA242432B0 |
L16RA242432B0 |
2400 |
32 |
||||
|
L16CB241822B0 |
L16RB241822B0 |
1800 |
22 |
Hexagon |
|||
|
L16CB241832B0 |
L16RB241832B0 |
1800 |
32 |
||||
|
L16CB242422B0 |
L16RB242422B0 |
2400 |
22 |
||||
|
L16CB242432B0 |
L16RB242432B0 |
2400 |
32 |
||||
|
L16CC241825B0 |
L16RC241825B0 |
1800 |
25 |
Half Moon |
|||
|
L16CC241832B0 |
L16RC241832B0 |
1800 |
32 |
||||
|
L16CC242425B0 |
L16RC242425B0 |
2400 |
25 |
||||
|
L16CC242432B0 |
L16RC242432B0 |
2400 |
32 |
||||
What is a Hot Snare Polypectomy
Hot snare polypectomy, the endoscopist advances the snare sheath, opens the snare and encircles the polyp. The snare is then slowly and progressively closed, with the aim of capturing 1-2 mm of normal tissue around the polyp,then use Electrocoagulation until complete closure is achieved and the polyp emris guillotined. Best used for polyps 10-19 mm in diameter.
Hot Snare Polypectomy Technique
Hot endoscopic snare polypectomy, which is using electrocoagulation on the basis of using cold snare. After hot snare polypectomy, another independent endoscopic surgeon judged whether the endoscopic eradication was successful. Afterward, additional EMR was performed at the polypectomy site to evaluate for the presence of residual polyp tissue,including an additional 1 to 2 mm clear margin, was resected by the snare and Endocut current after submucosal injection of a mixed solution.
Snare Polypectomy Procedure
In snare polypectomy, doctor will capture around the bottom of the polyp and use current to cut the growth off. Any remaining tissue or stalk is then cauterized.
Endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) techniques could be used on some polyps are considered more technically challenging or are associated with an increased risk of complications.
As one of endoscopy device companies, we will offer more types of related products for sale, anything you need, please leave us a message.
在线联系供应商
Other supplier products
| PTA Balloon Dilatation Catheter | The PTA Dilatation Catheteris used for PTA(Percutaneous Transluminal Angioplasty) procedure in the peripheral vasculature, including but not limite... | |
| Single-use Balloon Dilatation Catheter (Rapid Exchange) Single-stage Dilatation Balloons | Used to dilate strictures of the biliary duct and the alimentary tract. Features of Single-use ercp catheter(Rapid Exchange) Single-stage Dilata... | |
| Single-use Nasal Biliary Drainage Catheter | Used for temporary endoscopic drainage of the biliary duct through the nasal passage by use of an indwelling catheter. Features of Single-use Na... | |
| Polypectomy Snares (Hot & Cold) | Polypectomy snaresare indicated for use endoscopically for the removal of polyps. LeoMed offers a competitive polypectomy snare priceand high-qu... | |
| Sphincterotome | Used for cannulation of the ductal system and for sphincterotomy, if preloaded, also aids ERCP operation in the stenosis of bile duct difficult str... |
Same products
| High Precision Filter Infusion Set Sterile Disposable Clinical IV Therapy | 卖方: Hebei Zongkai Technology Co., LTD | Products DescriptionSterile Luer Lock Infusion Giving Sets IV Set Medical Intravenous Disposable ... | |
| High Precision Filter Infusion Set Sterile Disposable Clinical IV Therapy | 卖方: Hebei Zongkai Technology Co., LTD | Products DescriptionSterile Luer Lock Infusion Giving Sets IV Set Medical Intravenous Disposable ... | |
| Class I Sterile Test Tube PET Plastic Body Fluid Collection Clinical Use | 卖方: Hebei Zongkai Technology Co., LTD | Description of Disposable syringe: 1) Disposable syringe with three parts,luer lock or luer slip... | |
| Class I Sterile Test Tube PET Plastic Body Fluid Collection Clinical Use | 卖方: Hebei Zongkai Technology Co., LTD | Description of Disposable syringe: 1) Disposable syringe with three parts,luer lock or luer slip... | |
| Class I Sterile Test Tube PET Plastic Body Fluid Collection Clinical Use | 卖方: Hebei Zongkai Technology Co., LTD | Description of Disposable syringe: 1) Disposable syringe with three parts,luer lock or luer slip... |