Serum Separation Tubes
Golden VacTM SST serum lab tubegold-top vacuum blood tubes for serum determinations in chemistry, immunology, and serology tests. The Serum Separation Tube is Serum Blood Collection Tube.
Description of Serum Separation Tubes
01
Coated with ultrasonically spray-dried microscopic silica particles which activate blood clotting.
02
Contain an inert polymer gel that separates the serum from the blood clot during centrifugation, preventing contamination of the serum.
03
Gently mix the blood collection tube by inverting 5-6 times immediately to activate clotting after blood drawing.
04
Allow the tube to stand for 30 minutes or until the clot is formed before centrifuging.
05
Centrifugation: 1800-2200 g for 8-15 minutes at 18-25° C.
Specification of Serum Separation Tubes
Volume/ml |
Size/mm |
Additive |
Separator |
Material |
Cap Color |
Closure |
|
GD040SGC |
13X75 |
Clot Activator |
Gel |
PET/GLASS |
gold top serum separator tube |
Safety Cap+Rubber |
|
GD040SGC2 |
13X100 |
Clot Activator |
Gel |
PET/GLASS |
Safety Cap+Rubber |
||
GD050SGC |
13X100 |
Clot Activator |
Gel |
PET/GLASS |
Safety Cap+Rubber |
||
GD060SGC |
13X100 |
Clot Activator |
Gel |
PET/GLASS |
Safety Cap+Rubber |
||
GD080SGC |
16X100 |
Clot Activator |
Gel |
PET/GLASS |
Safety Cap+Rubber |
||
GD080SGCR |
16X100 |
Clot Activator |
Gel |
PET/GLASS |
Rubber Stopper |
||
GD085SGC |
16X100 |
Clot Activator |
Gel |
PET/GLASS |
Safety Cap+Rubber |
||
GD085SGCR |
16X100 |
Clot Activator |
Gel |
PET/GLASS |
Rubber Stopper |
All serum collection vialare supplied in 1000pcs or 1200 pcs/ctn.
Gongdong Medical offers a gold-top SST tube.
Customization is supported.
To know more about serum gel separator tube, click "What is a yellow-top serum separation tube".
How Do You Separate Serum from SST Tube?
When using a serum gel blood tube, collect the specimen using standard venipuncture technique. Gently invert the tube five times to mix the clot activator with the blood. Allow the tube to clot for 20-30 minutes in a vertical position. Centrifuge the tube for 10-15 minutes at about 1300-1800 xg. The centrifuge RPMs will differ depending on the centrifuge and rotor used. The gel barrier will develop, keeping the serum and clot apart.
Why Are Serum Separator Tubes Used?
The sst gold top tubeis used when they want to test the serum of the blood. For tests like (NA, K, CL, CO2, LD, HDL) any type of chemistry. It is also used for tests like neonatal bilirubin or an AFP non maternal. There is special gel that separates blood cells from serum, as well as particles to cause blood to clot quickly. The blood sample may then be centrifuged, allowing the clear serum to be removed for testing.
As a professional lab consumables manufacturer, Bohao has high-quality medical consumables. Welcome to contact us if needed.
在线联系供应商
Other supplier products
Sampling Loop | GongdongTM disposable sterile disposable loopsand sterile disposable needles, are made from high-quality plastics with high precision molding proce... | |
Vacutainer Holder (Blood Tube Holder) | Blood collection tube holderfor taking blood samples. Safety blood draw needle holderspecialized for venipuncture. Transparent tubes for optimal ob... | |
Cell Culture Plate Non-Treated | We supply OEM cell culture platewith treated culture surface and plates with surface for suspension culture. Description of Cell Culture Plate N... | |
Glucose Tube | Golden VacTM glucose tube is used for blood glucose, glucose tolerance, red blood cell electrophoresis, sugar hemoglobin, etc. The Glucose Tube is ... | |
Sharps Container | Standard disposable sharps container used to collect sharps waste, including syringes, infusion sets, hypodermic needles, surgical needles, etc. ... |
Same products
Vibration Fiber Fineness Tester | 卖方: G238BB Electronic Crockmeter | TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi ... | |
Fiber Length Analyzer | 卖方: G238BB Electronic Crockmeter | TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi ... | |
Fiber Crimp Elasticity Tester | 卖方: G238BB Electronic Crockmeter | TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi ... | |
Precision Fiber Microtome | 卖方: G238BB Electronic Crockmeter | TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi ... | |
Ozone aging chamber | 卖方: G238BB Electronic Crockmeter | TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi ... |