Thrombite Clot Retriever Device
What Is a Stent Retriever?
Thrombite™ Clot Retrieval Devices
HELICAL OPEN-SIDE STRUCTURE
HIGHER ACUTE RECANALIZATION RATE
The Thrombite™ clot retrieval device, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.
Thrombite™ Clot Retriever Device
PRODUCT FEATURES
HELICAL OPEN-SIDE STRUCTURE
enables Thrombite™ retriever to efficiently entwine and clamp the clot
assures clot retention for confident removal and revascularization
OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE
increases contact surface with thrombus and maximizes clot integration
EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION
optimizes clot retention during smooth navigation through the tortuous anatomies
PRODUCT FEATURES
Radiopaque markers on the distal end of the device increase device visibility
3 markers for the sizes with 3.0 and 4.0mm diameter
4 markers for the sizes with 5.0 and 6.0mm diameter
Advanced stent surface treatment process
RADIAL FORCE
High radial force is designed for clot integration at the initial stage of stent expansion
Low radial force at nominal stent diameter ensures atraumatic retrieval
RADIAL FORCE
How a Retriever StentProcedure Is Performed
Stent retriever procedureis generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retrievalproductreached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever devicewill be extracted along with the clot and finally leave your body.
If you want to know more about tonbridge news live, please visit our website.
在线联系供应商
Other supplier products
Peripheral Drug-eluting Stent System | OVERVIEW Peripheral Drug-eluting Stent System ZENFLEX® Pro Peripheral Drug-eluting Stent System, the 3rd peripheral drug-eluting stent in the... | |
Balloon Guiding Catheter(BGC) | Balloon Guiding Catheter For more information about bgc balloonsand bgc medical, please feel free to contact us! Zylox tonbridgeare a leading... | |
Peripheral Drug-eluting Stent System | OVERVIEW Peripheral Drug-eluting Stent System ZENFLEX® Pro Peripheral Drug-eluting Stent System, the 3rd peripheral drug-eluting medicated st... | |
Neuro Interventions | The continued innovation and development in neuro interventions bring more choices and possibilities to physicians and patients. ZyloxTonbridge, on... | |
Peripheral Vascular Treatment | Peripheral Vascular Treatment What Is Peripheral Vascular Disease? Peripheral Vascular Disease (PVD) refers to conditions that affect blood ves... |
Same products
Maternity and baby products of Different Brands | 卖方: O&K GROUP LIMITED | Okwishing supplies all kinds of Maternity and baby products of Different Brands. Okwishing () is ... | |
Medical Equipment of Different Brands | 卖方: O&K GROUP LIMITED | Okwishing supplies all kinds of Medical Equipment of Different Brands. Okwishing() is a cross-b... | |
MECHANIC ROBOT 6560T-B11HD 三目立体显微镜 | 卖方: 深圳维客修科技有限公司 | 描述 机械师标准版6560T-B11三目立体显微镜,放大倍数6.5-60X,45度倾斜360度旋转观察头,带WF10X25可调目镜。非常适合维修手机、平板电脑、手表等电子产品,适用于电子电路板、... | |
Outdoor Sports First Aid Kit | 卖方: Dongyang City Yonoel Outdoor Products Co., Ltd. | Tactical First Aid Kit, Outdoor Sports First Aid Kit, Camping Survival Bag, Medical Supplies: Fir... | |
ZM-6552TH 0.65X - 5.2X 双目三目立体显微镜,适用于主板维修 | 卖方: 深圳维客修科技有限公司 | 描述 Greenough ZM-6552TH 0.65X-5.2X双目/三目立体变焦显微镜适用于手机主板/电子电路板CPU BGA焊接维修、珠宝鉴定修复、实验室观察、学术研究等。ZM-6552T... |