Thrombite Clot Retriever Device
What Is a Stent Retriever?
Thrombite™ Clot Retrieval Devices
HELICAL OPEN-SIDE STRUCTURE
HIGHER ACUTE RECANALIZATION RATE
The Thrombite™ clot retrieval device, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.
Thrombite™ Clot Retriever Device
PRODUCT FEATURES
HELICAL OPEN-SIDE STRUCTURE
enables Thrombite™ retriever to efficiently entwine and clamp the clot
assures clot retention for confident removal and revascularization
OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE
increases contact surface with thrombus and maximizes clot integration
EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION
optimizes clot retention during smooth navigation through the tortuous anatomies
PRODUCT FEATURES
Radiopaque markers on the distal end of the device increase device visibility
3 markers for the sizes with 3.0 and 4.0mm diameter
4 markers for the sizes with 5.0 and 6.0mm diameter
Advanced stent surface treatment process
RADIAL FORCE
High radial force is designed for clot integration at the initial stage of stent expansion
Low radial force at nominal stent diameter ensures atraumatic retrieval
RADIAL FORCE
How a Retriever StentProcedure Is Performed
Stent retriever procedureis generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retrievalproductreached the position and passing through the clot. Then release to capture the clot. After that, the stent retriever devicewill be extracted along with the clot and finally leave your body.
If you want to know more about tonbridge news live, please visit our website.
在线联系供应商
Other supplier products
One of the top neurology medical device companies in China The pursuit of excellence is the best expression of care for life and our corporate conscience. | The continued innovation and development in neuro interventions bring more choices and possibilities to physicians and patients. Zylox-Tonbridge, o... | |
Aspira Catheter Instructions | Aspira Catheter Instructions What Is An Aspiration Catheter? The Cylone™ Aspiration Catheter is intended for use in the removal/aspiratio... | |
PTA Balloon Catheter | EASY ACCESS TO THE MOST CHALLENGING ANATOMIES The PTA cathetersare non-reusable semi-compliant coaxial design catheters consisting of an OTWballoo... | |
Peripheral Drug-eluting Stent System | OVERVIEW Peripheral Drug-eluting Stent System ZENFLEX® Pro Peripheral Drug-eluting Stent System, the 3rd peripheral drug-eluting medicated st... | |
Peripheral Vascular Treatment | Peripheral Vascular Treatment What Is Peripheral Vascular Disease? Peripheral Vascular Disease (PVD) refers to conditions that affect blood ves... |
Same products
RF4系列三目立体显微镜摇臂支架 | 卖方: 深圳维客修有限公司 | RF4 RF-FX23A RF-FX35A 7-50X连续变倍三目显微镜带折叠自由摆臂支架。RF4 RF-FX35A 7-50X三目立体显微镜带370mm摆动支架和RF-P016大硅胶焊盘,用于... | |
Medical Polyisoprene rubber pad for soft transfusion bag | 卖方: Taizhou KangLong Medical Treatment Technology Co., Ltd. | Medical Polyisoprene rubber pad for soft transfusion bag Stable production, Mature technology, Q... | |
The 51-piece Emergency Survival First Aid Bag | 卖方: Dongyang City Yonoel Outdoor Products Co., Ltd. | This Compact And Well-Organized First Aid Kit Is Designed To Provide A Wide Range Of Medical Supp... | |
RELIFE RL-M6T Pro B11 6.5X-65X Trinocular Stereo Microscope | 卖方: Phonefix | RELIFE RL-M6T Pro-B11 6.5X-65X Continuous Zoom Trinocular Stereo Microscope with B11 large area b... | |
Smoke Toxicity Tester | 卖方: 千实精密机电仪器检测设备有限公司 | TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi ... |