Pendulum Impact Testing Machine For Plastic Film
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Applications
This advanced Pendulum Impact Tester is specifically tailored for evaluating the impact resistance of various materials, including plastic film, composite film, metallic foil, and more. With applications ranging from scientific research and academic education to laboratory use, research institutes, and quality control departments, Pendulum Impact Tester is a versatile solution for precise and reliable testing.
Film:It is suitable for testing the resistance of plastic film, thin film and composite film to pendulum impact. Such as food and drug packaging bags with PE/PP composite film, aluminum plating film, aluminum plastic composite film, nylon film, etc
Paper, Sheet Testing:It is suitable for testing the impact resistance of paper and paperboard, such as aluminized paper for cigarette packaging and aluminum-plastic paper composite material for Tetra Pak packaging.
Standards
ASTM D3420:Standard Test Method for Flexural Properties of Plastics
ASTM D256:Standard Test Method for Izod Impact Strength of Plastics and Reinforced Plastics
ASTM D4812:Standard Test Method for Tensile Properties of Thermoplastic Films and Sheeting
ASTM D6110:Standard Test Method for Tensile Properties of Rubber and Elastomers (Dumbbell Shapes)
ISO 180:Plastics — Determination of Izod impact strength
ISO 179:Plastics — Determination of Charpy impact strength
ISO 8256:Plastics — Cellular plastics — Determination of tensile properties
ISO 7628:Fibre-reinforced plastics — Determination of flexural properties
ISO 9854:Textiles — Determination of tensile properties — Part 1: Breaking force and elongation at break
DIN 53453:Kunststoffe — Bestimmung der Schlagzähigkeit (Charpy-Verfahren)
DIN 53753:Kunststoffe — Bestimmung der Biegeeigenschaften
Features
1. Multi-Energy Range and High-Precision Testing
The equipment supports three adjustable impact energy levels: 1J, 2J, and 3J, with a resolution up to 0.001J, meeting the testing needs of flexible packaging materials ranging from thin to thick.
Punch sizes are available in Φ12.7mm, Φ19mm, and Φ25.4mm, while clamp diameters are compatible with Φ60mm and Φ89mm, accommodating samples of varying thicknesses and structures.
2. Constant Impact Velocity and Pneumatic System
The impact velocity is constant at 2.5m/s, ensuring repeatability of test results.
The pneumatic clamping and pendulum release system effectively reduces human error and improves test stability.
3. Intelligent Data Management
Equipped with a microcomputer control system, it supports parameter setting, automatic data statistics, and visualized result display.
Compatible with the Lystem™ laboratory data sharing system, enabling one-click generation and unified management of test reports.
Technical Parameters
| Technical Parameter | Specification |
|---|---|
| Applications | Impact Testing, Sample Testing, Strength Testing |
| Materials | Aluminum, Composites |
| Weight | 110 kg |
| Dimensions | 630×500×760 mm (W×D×H) |
| Power | 110-240VAC, 50-60hz |
| Display | 160 x 128 dots graphic LCD module with alphanumeric keypad |
Accessoriess
Izod Vice
Charpy Rest
Tension Impact Rest (Specimen in bed method)
Puncture Impact Fixture
Pipe Rest
Component fixture to customer requirements
Variable weight impact hammers up to 50 Joules
Thermal printer
Full safety enclosure
Low-temperature chamber
在线联系供应商
Other supplier products
| Flooring Materials Abrasion Resistance Tester | Standard ASTM D3884(Abrasion Resistance of Textile Fabrics) ISO 5470-1(Rubber or Plastics-Coated Fabrics - Abrasion Resistance) EN 660-2(Abrasio... | |
| Catheter Flow Meter | The Catheter Flow Meter is specifically designed for measuring the water flow rate of medical catheters, including non-vascular catheters, intravas... | |
| Diaper Side-Leakage Prevention Performance Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Meet the standard: Compliant with GB: GB/T 28004.1 Diapers Part 1: Baby Diapers. GB/T 280... | |
| Fabric Textile Ultraviolet Ray Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Assessing SPF value, UVA/UVB absorption, and UV protection of fabrics, sunscre... | |
| Material Surface Performance Comprehensive Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Material Surface Performance Comprehensive Tester is a modular instrument designed for ... |
Same products
| Medical Splint RDJ013 | 卖方: Hengshui Runde Medical Instruments Co.,Ltd | Medical Splint RDJ013 This medical aluminum splintis made of two layer IXPE and core aluminum al... | |
| Chest Seal | 卖方: Hengshui Runde Medical Instruments Co.,Ltd | Chest Seal The chest sealis an advanced occlusive wound dressing for open chest wounds. Thisches... | |
| Israel Bandage RDJ020 | 卖方: Hengshui Runde Medical Instruments Co.,Ltd | Israel Bandage RDJ020 Israel BandageRDJ020is an Israeli battle dressingwith non-adhesive dressin... | |
| Gen 7 Tourniquet RDJ006 | 卖方: Hengshui Runde Medical Instruments Co.,Ltd | Gen 7 Tourniquet RDJ006 Tourniquet Gen 7 tourniquet is a first aid and medic gearitemthat has be... | |
| First Aid Kit | 卖方: Hengshui Runde Medical Instruments Co.,Ltd | First Aid Kit This First Aid Kitis designed for rapid, effective emergency response in severe tr... |