Medical Face Mask flammability Test machine
This Medical Face Mask flammability Tester is mainly used to test the flame retardant performance of medical masks. The combustion performance of the mask is measured through a head mold wearing a mask device to contact with the flame at a certain linear speed.
The device is mainly used in the field of medical protection, and also can also be used for
testing flame retardant properties of other textile coating materials.
GB 19083-2010 Technical requirements of
medical protective masks
YY 0469-2011 Technical requirements of
medical surgical masks-Blood penetration
test device
GB 2626-2006 Respiratory protective products, Self - priming filtering particulates respirator-flammability
BS EN136-1998 Respiratory protective devices -Full face masks - Requirements testing, marking
Items Parameters
Linear velocity of head automatic movement (60±5)mm/s
Flame height 40±4mm
Flame temperature measurement Thermocouple detection
Burner height adjustment range 30mm
Metal head mold surface thickness 2~3mm,Resistance to flame combustion
Combustion timer 0~9999.9s
Accuracy ±0.1s
Power supply AC220V,50Hz,500W
Weight About 30kg
When the flame is (20±2)mm above the burner, the temperature is (800±50)℃.
distance between the top of the burner and mask lowest point is(20±2)mm.
在线联系供应商
Other supplier products
| Medical Face Mask flammability Test machine | This Medical Face Mask flammability Tester is mainly used to test the flame retardant performance of medical masks. The combustion performance of t... | |
| Medical Mask Differential Pressure Tester | Mask Differential Pressure Tester also be used to determine the gas exchange pressure difference of other textile materials. Medical Face Mask Air... | |
| Full Face Helmet Flame Resistance Tester | Full Face Helmet Flame Resistance Tester is the special test equipment mainly used for testing medical masks flame retardant properties. Instrument... | |
| Anti Synthetic blood penetration tester | The medical face mask blood penetration resistance test equipment, medical face mask blood penetration resistance test device and medical face mask... | |
| Medical masks touch flame retardant performance tester | The Medical masks touch flame retardant performance tester uses a needle burner of specified size (Φ 0.9mm) and uses specific gas (butane) to i... |
Same products
| Air Permeability Tester STD- F8 | 卖方: Standard International Group (HK) Limited | The Air Permeability Tester is designed to quickly and accurately measure the breathability and p... | |
| Surface Performance Tester STD-FB4 - A | 卖方: Standard International Group (HK) Limited | Introduction TheSurface Tester analyzes finger movements-particularly, strokes-performed by arti... | |
| Compression Tester STD - FB3 - A | 卖方: Standard International Group (HK) Limited | TheCompression Tester analyzes hand movements-particularly, pushing with a finger-performed by ar... | |
| Single - Strand Bending Tester STD - FB2 - SH | 卖方: Standard International Group (HK) Limited | Standards ASTM A370. ASTM A416. ISO6934.4 The Single Fiber Bending Tester makes it possible to ... | |
| Bending Tester STD- FB2 - S | 卖方: Standard International Group (HK) Limited | Compliance Standards ASTM D790 (Plastics Flexural Properties) ISO 178 (Flexural Strength of Rig... |















