Battery Adiabatic Calorimeter
Reference Standards
GB/T 36276 - 2023 *Lithium - ion Batteries for Electric Power Energy Storage
UL 9540A ASTM E1981 - 98(2012) SN/T 3078.1 - 2012 *Guidelines for the Evaluation of Thermal Stability of Chemicals - Part 1: Accelerated Calorimetry Method
USABC SAND99 - 0497. July 1999: 3.2 Thermal Stability Tests SAE J2464 - R2009: 4.4.2 Thermal Stability Tests Freedom CAR SAND 2005 - 3123: 4.1 Thermal stability UL 1973 GB 38031 - 2020 *Safety Requirements for Power Batteries of Electric Vehicles
Product Features
Precision: The self - heating detection sensitivity is far better than the standard detection threshold of 0.02°C/min. It has high thermal insulation performance and a small temperature difference between the wall and the sample. Efficiency: With an innovative heating wire assisted heating solution, the experimental efficiency can be increased by up to 5 times.
Safety: It is equipped with safety protection measures such as burst discs, pressure relief valves, and explosion - proof boxes. The professional alarm system design comprehensively ensures the safety of personnel and equipment. Innovation: It has the innovative function of adiabatic thermal runaway - gas production combined analysis, enabling a comprehensive acquisition of the characteristic parameters of battery thermal runaway.
Technical parameters:
Adiabatic chamber effective size: diameter 800mm, depth 520mm
Self-exothermic detection sensitivity: better than 0.02℃/min
Constant temperature wall sample temperature difference: ≤ 1℃
Temperature control range: RT ~ 300℃, configuration of low temperature module up to -25℃
Working pressure range: 0 ~ 2MPa
Temperature tracking rate: 0.02 ~ 15℃/min
Needle maximum stroke: stroke software can be set up
Charge and discharge electrode column overcurrent capacity: -1000A ~ 1000A
在线联系供应商
Other supplier products
| Paper smoothness meter | Paper smoothness meter - Other test instrument - standard Product Information: Implementation standards: ISO 5627 Paper and board - Determinatio... | |
| Bio-absorbable Internal Fixation Plates and Screws Tester | Standard YY/T 0509-2009 (China): Specifies mechanical testing protocols for orthopedic plates/screws made of hydrolyzable polymers, including ax... | |
| KES - G5 Compression Tester | Content The Compression Tester analyzes hand movements-particularly, movements by finger-performed by artisans and professionals when judging a ... | |
| Total Hip Joint Prostheses Wear Tester | Standard YY/T 0651.1-2016 (China): Specifies wear testing parameters for total hip prostheses, including angular motion, loading modes, and envi... | |
| HapLog Finger Tactile Sensor | HapLog sensor is a “sensor that measures natural finger operations” with a built-in contact force sensor and a 3-axis acceleration sens... |
Same products
| PH-2398 pH/EC/ORP/温度 多参数测试仪 | 卖方: 科立龙电子股份有限公司 | 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或... | |
| ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| 防水型 EC /TDS/温度三合一参数测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ... | |
| EC-98330 电导率营养测试棒 | 卖方: 科立龙电子股份有限公司 | 本营养测试仪适用于水培和农业应用,能够准确测量水中的营养液电导率(EC)单位为mS/cm,以及总溶解固体(TDS)转换为百万分之一(ppm)。 适合需要较高EC值的植物,该测试仪具有高达6.0... | |
| PH-808防水笔式土壤PH计 | 卖方: 科立龙电子股份有限公司 | 两点按键校准,自动识别pH标准缓冲液 自动温度补偿确保全量程范围的精确测量。 自动电源关闭,有效节省电池能耗。 可替换型电极降低仪表维护与使用成 全防水性能保障在恶劣环境中对仪表的完整保... |