Adiabatic Rate Calorimeter
Product Description
Battery Isothermal Calorimeter is a professional instrument developed based on the principle of power compensation isothermal calorimetry for testing the thermal characteristics of various types of lithium batteries, capable of realizing the measurement of the thermal characteristics of lithium batteries' charging and discharging as well as the thermal and physical parameters, providing accurate, stable and reliable basic thermal data for the thermal simulation of batteries, the optimization of the design of the thermal management system, as well as the assessment of the thermal safety performance of batteries.
Product Features
1. In an isothermal environment, it is compatible with the power compensation method and the heat - flow method to measure the heat generated during battery charging and discharging. This not only ensures the accuracy of thermal characteristic measurement for relatively large - sized batteries but also improves the sensitivity of heat measurement for relatively small - sized batteries.
2. It has an instrument calibration mode, which can calibrate the measurement accuracy of charging and discharging thermal behavior parameters under different conditions.
3. It is equipped with a heat capacity measurement mode. By using the comparative method to measure heat capacity, it reduces the operational requirements for heat capacity testing and can accurately measure the heat capacity of batteries at different temperatures.
4. The integrated battery charging and discharging module enables the switching of charging and discharging modes, the setting of constant - current/constant - voltage charging modes, the setting of charging/discharging currents, and the real - time calculation of battery power.
5. Network communication is adopted to achieve remote operation of the instrument and remote data transmission, ensuring the safety of testers.
6. It can simultaneously record voltage, current, and temperature data during the battery charging and discharging process.
7. An optional nitrogen purging module can be selected to ensure the accuracy of low - temperature measurement and effectively suppress the problem of low - temperature condensation.
Technical Specifications
|
Calorimeter Body |
(5~40)°C, <85%RH |
|
Operating Environment |
(-40~100)ºC |
|
Oil Bath Temperature Control Range |
Isothermal Power Compensation Mode, Isothermal Heat Flow Mode, Specific Heat Capacitance Mode |
|
Experimental Modes |
±0.005°C |
|
Temperature Stability |
|
|
Temperature Resolution |
L345mm×W230mm×H100mm |
|
Maximum Cell Size |
200W |
|
Maximum Compensated Power |
10mW (power compensation mode); 0.2mW (heat flow mode) |
|
Calorimetric Sensitivity |
±1% (power compensation mode); ±2% (heat flow mode) |
|
Absorption and Expiration Enthalpy Measurement Accuracy |
10mW (Power Compensation Mode); 0.2mW (Heat Flow Mode) |
|
Baseline Noise |
Standard with 2 channels |
|
Heating Channels |
Standard with 8 channels |
|
Temperature Measurement Channels |
RJ45 |
|
Instrument Interfaces |
(5~25)L/min |
|
Adjustable Gas Flow Rate |
AC220V/50Hz |
|
Power Supplied Power Supply |
600W |
|
Maximum Power |
(-55~200 )°C |
|
Oil Bath |
±0.01°C |
|
Setting Temperature Range |
|
|
Temperature Stability |
3kW |
|
Display Resolution |
|
|
Heating Power |
12×11/16cm |
|
Refrigeration Power |
5L |
|
Bath Openings/Size |
Serial port |
|
Charging |
(5~40)°C, <85%RH |
|
Calorimeter Body |
(-40~100)ºC |
在线联系供应商
Other supplier products
| Perspiring Thermal Artificial Foot | Perspiring Thermal Artificial Foot - Full Body 3D Scanning and Manikin - standard Standards: Applications: The sensory experience of sho... | |
| Double Plate Thermal Conductivity Apparatus | Standards: GB/T 10294-2008 ?Determination of Steady State Thermal Resistance and Related Properties of Thermal Insulation Materials GB/T 3399-19... | |
| Carpet Dynamic Load Tester | Instrument Features - Provide information on the reduction in the thickness of carpet pile - Imitate the pressure and shearing effects genera... | |
| Drawer slide durability testing machine | Meet the standard: ANSI/BIFMA X5.5 EN 15338 ISO 7170 Product Introduction: Drawer slides are fundamental components in furniture, cabinetr... | |
| In situ expansion analysis system | Standard ASTM E83: Standard Test Method for Verification of Linear Displacement Measuring Systems ISO 12417-1: Mechanical Testing of Metals &ndas... |
Same products
| PH-2398 pH/EC/ORP/温度 多参数测试仪 | 卖方: 科立龙电子股份有限公司 | 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或... | |
| ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| 防水型 EC /TDS/温度三合一参数测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ... | |
| EC-98330 电导率营养测试棒 | 卖方: 科立龙电子股份有限公司 | 本营养测试仪适用于水培和农业应用,能够准确测量水中的营养液电导率(EC)单位为mS/cm,以及总溶解固体(TDS)转换为百万分之一(ppm)。 适合需要较高EC值的植物,该测试仪具有高达6.0... | |
| PH-808防水笔式土壤PH计 | 卖方: 科立龙电子股份有限公司 | 两点按键校准,自动识别pH标准缓冲液 自动温度补偿确保全量程范围的精确测量。 自动电源关闭,有效节省电池能耗。 可替换型电极降低仪表维护与使用成 全防水性能保障在恶劣环境中对仪表的完整保... |