Salt Spray Test Machine
The Salt Spray Tester is used to create and maintain the salt spray (fog) test environment, and test the anti-corrosion quality of all the materials surfaces after the rust-proof of painting, coating, electroplating, anodizing and rust-proof of greasing.
Our salt spray testers available in two capacities meet ASTM-B117, JIS-D0201, JIS-H8502, JIS-H8610, JIS-Z2371 and other International Standards test methods. Power supplied can be configured upon request.
Feature & Parameters
1. The whole system using PVC plate, lined with the use of advanced three-dimensional reinforcement ring technology, structure and strong real, never deformation.
2. Five direction heating system to ensure heat distribution within ±1oC.
3. Highly advanced spray nozzle with accuracy of spray misting within ±0.3ml/80cm2.
4. Saturated air with Henry's law. In order to heated humidification, and provided the necessary laboratory humidity.
5. Temperature control uses P.I.D temperature controller within ±0.3oC accuracy.
6. The only use of early warning device test solution is too low, when the test solution is only enough for 5 hours and then spray the buzzer supplement will notify the user to ensure that the test of the value of the continuous spray.
7. The only use the full detection system, when a failure occurs, you can display or alarm lights inform.
8. With a spray and standing time period setting (for CAPA, SAE, ASTM).
9. Meets ASTM B117-03 the new improved design.
Application:
Corrosion resistance test for products after treated by plating, anodized, spraying, and anti-rust.
Standard:
ASTM B-117, DIN50021-75, JIS H8502, IEC 68-2-11, MIL-STD-750, ISO 9227,ISO 12944-6,ISO 20340,ISO 7253
1. The whole system using PVC plate, lined with the use of advanced three-dimensional reinforcement ring technology, structure and strong real, never deformation.
2. Five direction heating system to ensure heat distribution within ±1oC.
3. Highly advanced spray nozzle with accuracy of spray misting within ±0.3ml/80cm2.
4. Saturated air with Henry's law. In order to heated humidification, and provided the necessary laboratory humidity.
5. Temperature control uses P.I.D temperature controller within ±0.3oC accuracy.
6. The only use of early warning device test solution is too low, when the test solution is only enough for 5 hours and then spray the buzzer supplement will notify the user to ensure that the test of the value of the continuous spray.
7. The only use the full detection system, when a failure occurs, you can display or alarm lights inform.
8. With a spray and standing time period setting (for CAPA, SAE, ASTM).
9. Meets ASTM B117-03 the new improved design.
|
MODEL
|
STD-9701
|
STD-9701C
|
|
|
TEST APPLICABLE
|
NSS, ACSS, CASS
|
CORK
|
|
|
TEST TEMPERATURE
|
35oC±1oC or 50oC±1oC
|
38oC±1oC 80%~99%RH
|
|
|
INSIDE DIMENSION
|
900x600x500(WxDxH) mm
|
900x600x500(WxDxH) mm
|
|
|
OUTSIDE DIMENSION
|
1420x780x1280(WxDxH) mm
|
||
|
VOLUME
|
270 LITER
|
||
|
WEIGHT
|
150KGW
|
||
|
TEST SPECIMAN (150x70mm)
|
at angle of 20o±5
|
48 PCS
|
|
|
SOLUTION TANK
|
CAPACITY
|
30 LITER
|
|
|
TESTING TIME
|
180HR
|
||
|
POWER CONSUMPTION
|
220V SINGLE PHASE 3KW
|
||
在线联系供应商
Other supplier products
| Chin Strap Testing Machine | Standard GB/T 2812-2006: Safety Helmets GB/T 2811-2019: Head Protection – Vocabulary and Test Methods Equivalent Compliance: ISO/EN 397 ... | |
| Internal shoe size tester | Meet the standard: ISO 9407 Product Introduction: While external shoe size markings provide a general guide, the actual space inside a shoe di... | |
| High temperature vacum friction & wear tester | Main uses: High temperature vacuum friction and wear testing machine is mainly used to study the friction and wear characteristics of materials in... | |
| Model Coin-cell Swelling System | Standard ASTM E83: Standard Test Method for Verification of Linear Displacement Measuring Systems ISO 12417-1: Mechanical Testing of Metals &ndas... | |
| Oil-Water Separation Tester | Applicable Standards: (1)ISO/ TS 16332-2006 Diesel engine diesel filters Fuel Water Separation Efficiency Assessment Method. (2) ISO 4020-2001 Te... |
Same products
| KL‑016A Benchtop High‑precision pH Meter | 卖方: 科立龙电子股份有限公司ctron Co.Ltd | Product Description: Large‑screen display with high resolution and precision for con... | |
| Large Naïve VHH Library | 卖方: AlpVHHs | Large Naïve VHH Library VHHare single-domain antibodies derived from the variable regions o... | |
| PH-2398 pH/EC/ORP/温度 多参数测试仪 | 卖方: 科立龙电子股份有限公司 | 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或... | |
| ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| 防水型 EC /TDS/温度三合一参数测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ... |