.

Solid electrolyte analysis system

Whats/App: +86 156 1874 6768

Web: standard-groups.com

The Solid Electrolyte Analysis System is a precision testing platform designed to evaluate the ionic conductivity, electrochemical impedance, and interface resistance of solid-state and liquid battery electrolytes. By providing high-accuracy, non-destructive measurements under controlled temperature and environmental conditions, the system supports advanced R&D, quality control, and material characterization for lithium-ion, sodium-ion, and solid-state batteries. It enables multi-sample testing, rapid analysis, and seamless integration with data processing software.

Application

(1) Measurement of ionic conductivity and impedance of lithium-ion, sodium-ion, and solid-state battery electrolytes.

(2) Characterization of solid polymer electrolytes, ceramic electrolytes, and hybrid electrolytes for R&D and quality assurance.

(3) Interface resistance analysis between electrodes and solid electrolytes for battery performance optimization.

(4) Non-destructive testing of electrolyte materials to preserve sample integrity.

(5) High-throughput multi-sample testing (up to 16 samples simultaneously) for comparative studies and material screening.

(6) Temperature-dependent conductivity and impedance testing under controlled conditions (-20°C to 80°C).

(7) Integration into battery development workflows using LabVIEW, MATLAB, or Python for data analysis and visualization.

(8) 3D mapping of ionic diffusion pathways for advanced research and publication-quality analysis.

Standards

(1) ISO 9001:2015 – Quality management system for laboratory and R&D equipment.

(2) ASTM E1970-21 – Standard guide for electrochemical impedance spectroscopy.

(3) IEC 62660-2 – Secondary lithium-ion cells for propulsion of electric road vehicles.

(4) RoHS Compliance – Restriction of hazardous substances in electronic equipment.

(5) CE Certification – Conformité Européenne for safety and electromagnetic compliance.

Features

(1) Sub-micron precision ionic conductivity measurement with ±0.01% error margin.

(2) Advanced electrochemical impedance spectroscopy (EIS) with frequency range up to 10 MHz.

(3) Rapid testing workflow with AI-driven automation, completing analyses up to 80% faster than traditional systems.

(4) Multi-sample parallel testing capability (up to 16 samples).

(5) Intuitive touchscreen interface with multi-language support (English, Chinese, German, Japanese, etc.).

(6) Modular architecture for easy upgrades and maintenance.

(7) Military-grade IP67 enclosure for dust, moisture, and vibration resistance.

(8) Overvoltage/overcurrent protection with real-time self-diagnostics.

(9) Cloud-based data synchronization with AES-256 encryption and software integration for LabVIEW, MATLAB, and Python.

(10) Non-destructive testing preserving sample integrity with contactless impedance measurement.

(11) Precision Peltier temperature control system (-20°C to 80°C ±0.1°C stability).

(12) 3D visualization software for mapping ionic diffusion pathways and interface resistance.

Parameters

ParameterSpecification
Ionic Conductivity Range 10⁻⁸ S/cm to 10⁻² S/cm
Frequency Range 10⁻³ Hz – 10 MHz
AC Amplitude 1 mV – 1 V (adjustable)
Measurement Time 0.5 – 600 s (user-definable)
Data Resolution 24-bit ADC, 16 million data points per test
Temperature Control -20°C to 80°C (±0.1°C stability)
Power Supply 100–240V AC, 50/60 Hz (universal adapter)
Dimensions (W×D×H) 420 × 350 × 180 mm
Weight 12.5 kg (net) / 15 kg (gross)

Accessories

(1) High-Sensitivity Probe Kit: Platinum-iridium electrodes (2mm/5mm/10mm diameters) and non-conductive ceramic sample holder.

(2) Software Suite: SolidAnalyzer Pro license for Windows/macOS/Linux with 1-year cloud analytics access.

(3) Safety & Maintenance: Anti-static gloves (3 pairs), ISO 17025 certified calibration fluid (100 mL), cleaning kit (lint-free wipes, alcohol solution).

(4) Portability: Reinforced aluminum carrying case with custom foam inserts and universal detachable power cord.

Test Procedures

(1) Install the electrolyte sample in the ceramic sample holder and connect electrodes.

(2) Select or create a testing protocol specifying frequency range, AC amplitude, temperature, and duration.

(3) Start the test; the system performs impedance spectroscopy and records ionic conductivity, resistance, and related parameters.

(4) Monitor real-time data on the touchscreen interface or cloud platform.

(5) Export test results for R&D, quality control, or publication purposes.

Maintenance Information

(1) Inspect electrodes, ceramic holders, and connectors regularly for wear or contamination.

(2) Calibrate the system periodically using certified calibration fluids to maintain measurement accuracy.

(3) Keep the touchscreen, control system, and data acquisition hardware clean and dry.

(4) Verify overvoltage and overcurrent protection systems before operation.

(5) Store the system in a clean, vibration-free environment when not in use.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Automotive & Electronics Touch Perception Testing System | Factory Direct China
Automotive & Electronics Touch Perception Testing System | Factory Direct China Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features (1) Multi-parameter measurement of roughness, indentation, rebound,...
Standard light source sample table
Standard light source sample table Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO 3664:2009: Meets international standards for graphic arts and photography vi...
Oxidizing Solids Tester
Oxidizing Solids Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Conforms to UN Recommendations on the Transport of Dangerous Goods - Manual of Tests and Cr...
Automated thermal property analyzer for high-temperature materials
Automated thermal property analyzer for high-temperature materials Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The tester is suitable for: Scientific research laboratories studying thermal...
Benchtop tracking index tester
Benchtop tracking index tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Tracking Tester is suitable for testing the tracking resistance of various...
供应产品

Same products

PH-2398  pH/EC/ORP/温度 多参数测试仪
PH-2398 pH/EC/ORP/温度 多参数测试仪 卖方: 科立龙电子股份有限公司 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或...
ORP-2026S  防水型 土壤ORP&温度 二合一测试仪
ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 卖方: 科立龙电子股份有限公司 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV...
防水型 EC /TDS/温度三合一参数测试仪
防水型 EC /TDS/温度三合一参数测试仪 卖方: 科立龙电子股份有限公司 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ...
EC-98330 电导率营养测试棒
EC-98330 电导率营养测试棒 卖方: 科立龙电子股份有限公司 本营养测试仪适用于水培和农业应用,能够准确测量水中的营养液电导率(EC)单位为mS/cm,以及总溶解固体(TDS)转换为百万分之一(ppm)。 适合需要较高EC值的植物,该测试仪具有高达6.0...
PH-808防水笔式土壤PH计
PH-808防水笔式土壤PH计 卖方: 科立龙电子股份有限公司 两点按键校准,自动识别pH标准缓冲液 自动温度补偿确保全量程范围的精确测量。 自动电源关闭,有效节省电池能耗。 可替换型电极降低仪表维护与使用成 全防水性能保障在恶劣环境中对仪表的完整保...