The thoracic drainage tester is widely applied in the medical field, mainly used for monitoring and evaluating the performance of thoracic drainage devices and the thoracic drainage situation of patients. The following is a detailed introduction to the main uses, compliance standards, and technical parameters of the thoracic drainage tester:
Main Uses
Monitoring and Assessment: The thoracic drainage tester can comprehensively monitor and assess thoracic drainage, covering multiple key indicators such as drainage volume, drainage speed, and the pressure in the drainage tube. The accurate measurement and monitoring of these data help doctors promptly understand the changes in patients' conditions, thus enabling them to make more precise treatment decisions.
Enhancing Treatment Efficacy: By providing accurate data and references for clinicians, the tester contributes to improving the treatment efficacy and recovery rate of patients. Doctors can carry out personalized treatment for patients based on the data provided by the tester and optimize the treatment plans. Surgical Monitoring and Condition Evaluation: After thoracic drainage surgery, the tester can promptly monitor the drainage status, assisting medical staff in understanding the surgical outcome and guiding further treatment. Meanwhile, through continuous monitoring of patients' physiological parameters, the tester helps medical staff evaluate patients' conditions and formulate more reasonable treatment plans. Adaptability Testing: Some thoracic drainage testers are also equipped with an adaptability testing function, which is used to assess the adaptability indicators of thoracic drainage devices, ensuring the stability and reliability of the devices when simulating changes in thoracic pressure.
Standards
The design, manufacture, and use of thoracic drainage testers should comply with relevant medical industry standards to ensure the accuracy and reliability of test results. Common compliance standards includeYY/T 0583.1. etc.
Technical Parameters
Pressure Range:The pressure range of the tester is usually wide to adapt to the needs of different thoracic drainage devices and patients. For example, the pressure range can reach -10020kPa (-10010kPa, depending on the specific model), with an accuracy of 0.5%FS.
Flow Range:The flow range is also one of the important technical parameters of the tester, used to evaluate the drainage capacity of thoracic drainage devices. For instance, the flow range can be 0 - 1000mL/min, with the same accuracy of 0.5%FS.
Air Source Pressure and Interface:The tester is typically equipped with an air - source interface for connecting to air - source equipment (such as an air compressor) to supply the required air pressure for testing. The air - source pressure generally does not exceed 0.7MPa (the user needs to provide the air source), and the air - source interface is usually a Φ6mm or Φ8mm polyurethane tube.
Power Supply:The power supply of the tester usually supports a wide voltage range, such as AC100 - 240V, 50/60Hz, to adapt to the electrical standards of different countries and regions.
Operation Interface and Display:The tester is usually equipped with a color touch - screen operation interface, supporting Chinese - English switching (or other languages). The interface is clear and straightforward, making it easy for medical staff to operate and use. Meanwhile, the tester also has real - time data display and recording functions, facilitating medical staff to view and analyze test results.
External Dimensions and Weight:The external dimensions and weight of the tester vary depending on the model, but it is generally designed to be compact and lightweight for easy portability and use. For example, the external dimensions may be 390mm(L)×410mm(W)×190mm(H) (the specific dimensions depend on the model), and the weight is moderate, which is convenient for medical staff to move and operate.
Other Functions:Some testers are also equipped with additional functions such as automatic calibration, fault diagnosis, data export, and printing to improve testing efficiency and convenience.
在线联系供应商
Other supplier products
| Solid Auto - ignition Point Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com This tester determines the self - ignition characteristics of solid chemical products by pl... | |
| ASTM G99 Wide-Range Load Friction and Wear Testing Machine for Tribology Research | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Wide-Range Load Friction and Wear Testing Machine is a versatile tribolog... | |
| Chest Drainage Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The thoracic drainage tester is widely applied in the medical field, mainly used for monito... | |
| Scrub Abrasion Test device | Whats/App: +86 156 1874 6768 Web: standard-groups.com T107 Scrubbing Tester, It is suitable for various abrasion and wet scrubbing tests, which i... | |
| Bench-top Mechanical load testing machine for photovoltaic modules | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The machine is widely used for mechanical performance testing and structural v... |
Same products
| PH-2398 pH/EC/ORP/温度 多参数测试仪 | 卖方: 科立龙电子股份有限公司 | 大显示,可同时进行水质PH、氧化还原电位、电导率、温度的测量; 带背光LCD显示清晰,功能齐全,精度高; 仪表采用微电脑测量与控制技术,具有自动校准功能,方便实用。 内置蓝牙,可以与电脑或... | |
| ORP-2026S 防水型 土壤ORP&温度 二合一测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV... | |
| 防水型 EC /TDS/温度三合一参数测试仪 | 卖方: 科立龙电子股份有限公司 | 范围 EC ~19.9mS TDS Temp 0~50℃ 分辨率 ... | |
| EC-98330 电导率营养测试棒 | 卖方: 科立龙电子股份有限公司 | 本营养测试仪适用于水培和农业应用,能够准确测量水中的营养液电导率(EC)单位为mS/cm,以及总溶解固体(TDS)转换为百万分之一(ppm)。 适合需要较高EC值的植物,该测试仪具有高达6.0... | |
| PH-808防水笔式土壤PH计 | 卖方: 科立龙电子股份有限公司 | 两点按键校准,自动识别pH标准缓冲液 自动温度补偿确保全量程范围的精确测量。 自动电源关闭,有效节省电池能耗。 可替换型电极降低仪表维护与使用成 全防水性能保障在恶劣环境中对仪表的完整保... |