Disposable Biopsy Forceps

Intended use
Tissue sampling in digestive and respiratory tracts.
Features
Special sharpness treatment on cups,Website:, easier to sample. Innovational 4-bar linkage design, offering an excellent rigidness. Tiny interval between jaws, large occlusal force and outstanding fitness. Smooth jaws, effectively decrease the friction to working channel. Standard cups design with proper sampling capacity, small tissue harm.
Specifications●Disposable Biopsy Forceps(without coating)
Model
O.D. (mm)
Length (mm)
Endoscope Channel (mm)
Characteristics
JHY-FB-18-105-O-O
1.8
1050
≥2.0
without spike, uncoated
JHY-FB-18-105-W-O
1.8
1050
≥2.0
with spike, uncoated
JHY-FB-18-160-O-O
1.8
1600
≥2.0
without spike, uncoated
JHY-FB-18 -160-W-O
1.8
1600
≥2.0
with spike, uncoated
JHY-FB-23-160-O-O
2.3
1600
≥2.8
without spike, uncoated
JHY-FB-23 -160-W-O
2.3
1600
≥2.8
with spike, uncoated
JHY-FB-23-180-O-O
2.3
1800
≥2.8
without spike, uncoated
JHY-FB-23-180-W-O
2.3
1800
≥2.8
with spike, uncoated
JHY-FB-23-200-O-O
2.3
2000
≥2.8
without spike, uncoated
JHY-FB-23-200-W-O
2.3
2000
≥2.8
with spike, uncoated
JHY-FB-23-230-O-O
2.3
2300
≥2.8
without spike, uncoated
JHY-FB-23-230-W-O
2.3
2300
≥2.8
with spike, uncoated
Specifications●Disposable Biopsy Forceps(with coating)
Model
O.D. (mm)
Length (mm)
Endoscope Channel (mm)
Characteristics
JHY-FB-18-105-O-P
1.8
1050
≥2.0
without spike, coated
JHY-FB-18-105-W-P
1.8
1050
≥2.0
with spike, coated
JHY-FB-18-160-O-P
1.8
1600
≥2.0
without spike, coated
JHY-FB-18-160-W-P
1.8
1600
≥2.0
with spike, coated
JHY-FB-23-160-O-P
2.3
1600
≥2.8
without spike, coated
JHY-FB-23-160-W-P
2.3
1600
≥2.8
with spike, coated
JHY-FB-23-180-O-P
2.3
1800
≥2.8
without spike, coated
JHY-FB-23-180-W-P
2.3
1800
≥2.8
with spike, coated
JHY-FB-23-200-O-P
2.3
2000
≥2.8
without spike, coated
JHY-FB-23-200-W-P
2.3
2000
≥2.8
with spike, coated
JHY-FB-23-230-O-P
2.3
2300
≥2.8
without spike, coated
JHY-FB-23-230-W-P
2.3
2300
≥2.8
with spike, coated
Other supplier products
|
|
|
Innovational triple anti-drop design at Hydrophilic tip,Website:, with no risk of drop-off.Anti-twist innerNiti core wire, offering an excellent tw... |
|
|
|
FeaturesSpecial designed loop with thinner wire,Website: a clean cut.Suitable for diminutive polypectomy.SpecificationsModelO.D(mm)Length(mm)Loop W... |
|
|
|
Intended useGrasp and remove foreign bodies from digestive tract.SpecificationsModelO.D.(mm)Length(mm)Endoscope Channel(mm)NET Size (mm)JHY-FG-18-1... |
|
|
|
Name:(Disposable) Endoscopic Spray CatheterUsage: combined use with endoscope,Website:, spray catheter is used for spraying hemostasis medicine, st... |
|
|
|
SpecificationsBiopsy ValveModelCharacteristicsJHY-BV-A1Disposable,Website:, for Olympus & Fujinon EndoscopeJHY-BV-B1Disposable, for Pentax Endoscope |
供应产品
Same products