Chrom-LinX® Empty Chromatography Column

Chrom-LinX® large glass chromatography columnscan be divided into two designs: single and double adjustable cylinder. The single adjustable cylinder design mainly consists of adjustable cylinder, column tube and fixed cylinder. The double adjustable cylinder design replaces the fixed cylinder with an adjustable cylinder to extend the volume range that can be loaded. Chrom-LinX® laboratory grade chromatographic column is standard with 10 μm screen (optional 5 μm screen) and is compatible with common tomographic fillers of different particle sizes.

Chrom-LinX® laboratory grade chromatographic columns are made of biocompatible materials with good chemical tolerance. It is compatible with common aqueous solutions and most organic solvents, but does not tolerate chlorinated hydrocarbons, acetone and other ketones, fatty esters and phenol, etc. At the same time, it is prohibited to use under the condition of containing more than 2 M NaOH, 1 M HCl, other strong inorganic acids, 75% acetic acid solution.

Please be advised that this product is only available for sale and after-sales support in certain regions. For further details, kindly consult with your local sales representative. Thank you for your understanding.

Features and Benefits of Chrom-LinX Laboratory Grade Empty Columns

User-friendly design: Ergonomically design the components for easy grasping and handling.

Clear view: Equipped with a measurement scale of glass tube for easy to predict and reach a predefined bed height and improving process reproducibility.

High pressure resistance: compatible with common resins of different particle sizes allowing operation up to 20 bar* (2 MPa, 290 psi) pressure.

Various sizes: Glass tubes with inner diameter (i.d.) of 10 mm, 16 mm, 26 mm or 50 mm, and bed height of 200 mm, 400 mm, 700 mm or 1000 mm provide a wide range of column volumes.

High flexibility: Equipped with single/double adjustable capital for flexible expansion of column volumes.

Easy to clean: Each component for easy assembling removing and cleaning.

Compatibility: Supplied with tubing and connectors suitabling for a variety of common laboratory tomographic systems.

*The columns withstands pressures up to 7 bar (0.7 MPa, 101.5 psi) with 50 mm inner diameter.

Product Characteristics of Chrom-LinX Laboratory Grade Empty Columns

Chrom-LinX® laboratory grade empty chromatography columnare divided into two designs: single adjustable capital and double adjustable capital. The design of single adjustable capital mainly consists of an adjustable capital, a chromatography column tube and a fixed capital. The design of double adjustable capital replaces the fixed capital with an adjustable capital to extend the column volume (Fig 2).

Chrom-LinX® laboratory grade empty chromatography columnsis standard equipped with 10 μm net ring (5 μm net ring being also optional), which is compatible with common resins of different particle sizes.

Chemical Resistance of Chrom-LinX Laboratory Grade Empty Columns

Chrom-LinX® laboratory gradechromatography columns emptyare made of biocompatible materials with good chemical tolerance. The columns can be used in aqueous solutions and almost all the organic solvents commonly used in liquid chromatography of macromolecules. The columns intolerant of chlorinated hydrocarbons, acetone and other ketones, aliphatic esters, and phenol. The columns are not allowed to use the solution containing more than 2 M NaOH, 1 M HCl, other strong mineral acids, or 75% acetic acid.

Specifications of Empty Chromatography Column

Empty columns

Table 1. Parameter of the Chrom-LinX® laboratory scale empty columns

Product code*

Column**

Column height (mm)

Bed height (mm)

Bed volume (ml)

2110-1111

Chrom-LinX 10/200

200

0-155

0-12

2110-1112

Chrom-LinX 10/400

400

225-355

18-28

2110-1122

Chrom-LinX 10/400P

400

0-355

0-28

2116-1111

Chrom-LinX 16/200

200

0-155

0-31

2116-1112

Chrom-LinX 16/400

400

225-355

45-71

2116-1122

Chrom-LinX 16/400P

400

0-355

0-71

2116-1113

Chrom-LinX 16/700

700

525-655

105-132

2116-1123

Chrom-LinX 16/700P

700

355-655

71-132

2116-1114

Chrom-LinX 16/1000

1000

825-955

166-192

2116-1124

Chrom-LinX 16/1000P

1000

655-955

132-192

2126-1111

Chrom-LinX 26/200

200

0-155

0-82

2126-1112

Chrom-LinX 26/400

400

225-355

119-188

2126-1122

Chrom-LinX 26/400P

400

0-355

0-188

2126-1113

Chrom-LinX 26/700

700

525-655

278-347

2126-1123

Chrom-LinX 26/700P

700

355-655

188-347

2126-1114

Chrom-LinX 26/1000

1000

825-955

438-507

2126-1124

Chrom-LinX 26/1000P

1000

655-955

347-507

2150-1111

Chrom-LinX 50/200

200

0-155

0-304

2150-1112

Chrom-LinX 50/400

400

225-355

441-697

2150-1122

Chrom-LinX 50/400P

400

0-355

0-697

2150-1113

Chrom-LinX 50/700

700

525-655

1030-1285

2150-1123

Chrom-LinX 50/700P

700

355-655

697-1285

2150-1114

Chrom-LinX 50/1000

1000

825-955

1619-1874

2150-1124

Chrom-LinX 50/1000P

1000

655-955

1285-1874

Instructions of Chrom-LinX® Empty Chromatography Column

Chrom-LinX® laboratory grade empty chromatography columns may be used at temperatures from 4° C to 40° C and pressures up to 20 bar (2 MPa, 290 psi) with inner diameters of 10 mm, 16 mm and 26 mm, and 7 bar (0.7 MPa, 101.5 psi) with an inner diameter of 50 mm.

Always clean the column and components with purified water before using.

When packing the column, the double top cap can be rotated, and the threaded shaft moves axially. This operation makes the resins easy to compress. If necessary, column packing can be performed using either a packing tube (Fig 4) or an extra column tube attached with a packing connector.

As a professional lifescience company, BioLinkis committed to continuously providing customers with high-quality innovative products and solutions.



在线联系供应商

至: 百林科 Bio-Link
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Depth Filtration Bioprocess Fixture Type M
Depth Filtration Bioprocess Fixture Type M The depth filtration system is designed to remove large cell particles in the preparation of biological products, such as cell clar- ification (in ...
Puredex G Series Resins for Size Exclusion Chromatography
Puredex G Series Resins for Size Exclusion Chromatography Puredex G is a series of sephadex size exclusionwith a cross-linked dextran-based matrix, which can separate different molecules by molecular weigh...
Chrom-LinX® Empty Chromatography Column
Chrom-LinX® Empty Chromatography Column Chrom-LinX® large glass chromatography columnscan be divided into two designs: single and double adjustable cylinder. The single adjustable cyl...
3D Round Plastic Lab Support Bucket
3D Round Plastic Lab Support Bucket 3D Round Plastic Lab Support Bucket Round plastic laboratory bucketare designed for small volume buffers, intermediates. Our lab bucket can be mat...
BioHub Aseptic Connector & Disconnector
BioHub Aseptic Connector & Disconnector Single-use solutions are increasingly being used in bioprocessing production. For single-use bioprocessing, reliable connection and disconnection o...
供应产品

Same products

Chlortetracycline Premix
Chlortetracycline Premix 卖方: Hebei Shengxue Dacheng Pharmaceutical Co., Ltd. Precautions for the use of Chlortetracycline Premix in livestock feed 1. Strict compliance: &midd...
Chlortetracycline Premix
Chlortetracycline Premix 卖方: Hebei Shengxue Dacheng Pharmaceutical Co., Ltd. Chlortetracycline Premix in livestock and poultry feed: 1. Purpose: · Promote the growth o...
Chlortetracycline Premix
Chlortetracycline Premix 卖方: Hebei Shengxue Dacheng Pharmaceutical Co., Ltd. Uses of Chlortetracycline Premix ·Livestock and poultry health: Chlortetracycline Premix i...
Chlortetracycline Premix
Chlortetracycline Premix 卖方: Hebei Shengxue Dacheng Pharmaceutical Co., Ltd. Characteristics of Chlortetracycline Premix ·Natural fermentation products: Chlortetracycl...
Chlortetracycline Premix
Chlortetracycline Premix 卖方: Hebei Shengxue Dacheng Pharmaceutical Co., Ltd. Chlortetracycline Premix is a feed additive that combines chlortetracycline with premix technolog...