YTA110 Temperature Transmitter
YTA110 Temperature TransmitterFeature :The YTA110 is the high performance temperature transmitter that accepts Thermocouple,Website:, RTD, ohms orDC milivolts inputs and converts it to a 4 to 20 mA DC signal for transmission. The YTA110 supports eitherBRAIN or HART communication protocol. The YTA110 in it standard configuration is certified byTU ¨ V as complying with SIL2 for safety requirement. Specifications :Accuracy(A/D accuracy/span + D/A accuracy) or 0.1 % ofcalibrated span, whichever is greater.See Table 1. on page 3.Cold Junction Compensation Accuracy(For T/C only)± 0.5˚C (± 0.9 ˚F)Ambient Temperature Effect (per 10 ˚C change)± 0.1 % or ± (Temperature Coefficient /span),whichever is greater. See Table 2. for TemperatureCoefficient.StabilityRTD:0.1% of reading or 0.1°C per 2 years,whichever is greater at 232°C.T/C:0.1% of reading or 0.1°C per year,whichever is greater at 232°C.5 Year StabilityRTD:0.2% of reading or 0.2°C,whichever is greater at 232°C.T/sC:0.4% of reading or 0.4°C,whichever is greater at 232°C.RFI EffectTested per EN 50082-2, field intensity up to 10 V/m.Power Supply Effect±0.005 % of calibration span per voltVibration Effect10 to 60 Hz 0.21 mm peak displacement60 to 2000 Hz 3GPosition EffectNone FUNCTIONAL SPECIFICATIONSInputInput type is selectable: Thermocouples, 2-, 3-, and4-wire RTDs, ohms and DC milivolts. See Table 1.on page 3.Span & Range LimitsSee Table 1. on page 3.Input signal source resistance (for T/C, mV)1 k or lowerInput lead wire resistance (for RTD, ohm)10 per wire or lowerOutputTwo wire 4 to 20 mA DC. Output range: 3.68 mA to20.8 mABRAIN or HART ® protocol is superimposed on the4 to 20 mA signal.Any single value from the followings can be selectedas the analog output signal.Sensor 1, Terminal Temperature.Also, up to three of the above values can be displayed on LCD display or read via communication.IsolationInput/Output/GND isolated to 500 V DC Teachnical parameters : Products Show :Why chose us :
Other supplier products
|
|
wika Diaphragm pressure gauge high overpressure safety 432.56,Website:, 432.36Applications■ For measu... |
|
|
Capsule pressure gauge Stainless steel Special features■ High overpressure safety up to 50 x full scale value■ Measuri... |
|
|
2088 Pressure TransmitterFeature :Proven Reliability for Gage and Absolute Applications• Available protocols include 4-... |
|
|
EJA510A EJA530A Absolute and Gauge PressureFeatures :The absolute and gauge pressure transmitter model EJA510A ... |
|
|
EJA110A Differential Pressure TransmitterFeatures: The high performance differential pressure transmitter ... |
供应产品
Same products