EM-5 Flue Gas Analyzer
Overview
EM-5 series flue online gas analyzeris a series of self-developed gas analysis products for online gas analysisof domestic as well as foreign environmental protection and industrial control. Based on UV Differential Optical Absorption Spectroscopy (DOAS) technology and chemometrics algorithm (PLS), it is able to measure the gas concentration of SO2, NO, NO2, O2, NH3, Cl2, O3, H2S, Ch3 and etc.
Features Of EM-5 Flue Gas Analyzer
High measurement accuracy
Minimum detection limit of SO2, NO, NO2 can reach 1mg/m3 (15m optical path)
Ultraviolet has no moisture absorption, undisturbed by moisture and dust
No cross interference between measured gases (refer to table 1)
Measure NO and NO2 simultaneously without converter
Low detection limit
Measuring gas Interference |
SO2 |
NO |
NO2 |
O2 |
SO2 (500ppm) |
/ |
<1ppm |
no |
no |
NO (500ppm) |
no |
/ |
no |
no |
NO2 (500ppm) |
no |
<1ppm |
/ |
no |
H2O (no dew) |
no |
no |
no |
no |
CO (1000ppm) |
no |
no |
no |
no |
CO2 (20%) |
no |
no |
no |
no |
O2 (21%) |
no |
no |
no |
/ |
High reliability
Small zero drift and span drift
Modular design
No optical moving parts, without vibration influence
Strong gas chamber, low cost
Automatic adjustment spectrum technology, long maintenance-free period
Adopt pulse light source with 10-year service life
Technical Parameter Of EM-5 Flue Gas Analyzer
Measurement Principle |
UV-DOAS+PLS |
|||||||
Versions |
Regular range |
Low range |
Ultra-low range |
|||||
Ranges |
Min range |
Max range |
Min range |
Max range |
Min range |
Max range |
||
Component |
SO2 |
0-300ppm |
0-3000ppm |
0-100ppm |
0-300ppm |
0-50ppm |
0-100ppm |
|
NO |
0-300ppm |
0-3000ppm |
0-100ppm |
0-300ppm |
0-50ppm |
0-100ppm |
||
NO2 |
0-500ppm |
0-4000pp |
0-300ppm |
0-1000ppm |
0-100ppm |
0-200ppm |
||
O2 (ECD or ZrO2) |
0-5% |
0-25% |
0-5% |
0-25% |
0-5% |
0-25% |
||
Linearity |
≤±3%F.S. |
|||||||
Repeatability |
≤2% |
|||||||
Zero Drift |
≤±2%F.S./7d |
|||||||
Span Drift |
≤±2%F.S./7d |
|||||||
Response Time(T90) |
≤50s |
|||||||
Working Temperature |
-20℃~+50℃ |
|||||||
Preheating Time |
No preheating |
20min |
40min |
|||||
Sample Gas Interface |
Φ6 Bi-Lok |
|||||||
Sample Gas Flow |
Range: (0.5~2)L/min, fluctuation<25% |
|||||||
Sample Gas Pressure |
Current ambient pressure ±0.1Bar |
|||||||
SampleGas Temp. |
0℃~+50℃ |
|||||||
Sample Gas Humidity |
No condensation (under sample gas temperature) |
|||||||
4-20mA Input |
3 , configurable, 100Ω load |
|||||||
4-20mA Output |
5, output content can be configured, maximum load capacity ≤800Ω |
|||||||
Switching valueInput |
6 , configurable |
|||||||
Relay Output |
14, output content can be configured. DC30V2A |
|||||||
Digital I/O |
1×Rs232, 1×Rs485 (Support Modbus protocol) |
|||||||
Installation Method |
19’panel |
|||||||
Supply Voltage |
220VAC±10% |
|||||||
Rated Power |
About 100W |
About 120W |
Application Of EM-5 Flue Gas Analyzer
Coal-fired power plant
Cement plant
Industrial furnace
DeSOX process monitoring
DeNOX process monitoring
Waste incineration plant
PVC process in chlor-alkali plant
Titanium dioxide production process
Sulfur recovery process
Natural gas purification process
Methyl iodide analysis for the coal chemical industry
On-line air monitoring
With features of high measurement accuracy, high reliability, fast response time, wide application scope, it can be widely applied in occasions of environment online monitoring, industrial process control, safety monitoring and etc.
Depended on years of flue gas analyzer research experience and combined with practical experience of thousands of successful application cases, the analyzer has derived multiple types (standard type, low emission type, ultra-low emission type, and customized type) to meet different index requirements in different working condition.
UV DOAS technology. The optical technology platform consists of a light source, gas chamber, optical fiber and spectrograph (including the diaphragm, a holographic grating, linear array detector) and other optical components.
Ultraviolet light emitted by light source enters the gas chamber by an optical window and absorbed by measured sample gas flowed through the gas chamber. The light carrying sample absorption information will be gathered by the lens and coupled into an optical fiber and then transmits into spectrometer through fiber. After light splitting and photo-voltaic conversion, the gas absorption spectrum is obtained.
The corresponding component concentration in the gas can be calculated by analyzing the spectrum.
Note: the difference among standard analyzer, low emission analyzer, and ultra-low analyzer is the different optical path length of gas chamber; for standard analyzer, it adopts dual lens collimation system with 0.25m optical path; for low emission analyzer, it adopts multiple return structure with 1m optical path; for ultra-low emission analyzer, it uses white cell structure.
Zetian Group has high-quality continuous flue gas analyzerfor sale, flue gas analyser for saleand gas analyzer for sale,contact us now.
Our company is good at flue gas analyser working principleand we also produce air quality monitor,online flue gas analyzer,online gas analyzerand online gas analyser.
在线联系供应商
Other supplier products
EM-5P Portable Flue Gas Analyzer | Overview EM-5P portable gas monitoring system mainly consists of gas monitoring sensors (SO2, NOx, CO, CO2), sample conditioning unit, sampling uni... | |
EQMS VOCs Online Monitoring System | What is 2.5 monitor? Volatile Organic Compounds (VOCS) are carbon based compounds that pose a significant health hazard due to their toxicity. VOCs... | |
WDet-5000UVI Immersion UV Water Analyzer | Overview Of WDet-5000UVI Immersion UV Water Analyzer WDet-5000UVI is the first full-spectrum (200-800nm) immersion UV portable water quality analy... | |
HM-200 Hygronom | Overview Hygronom is used to measure the humidity of flue gas emitted by pollution sources. According to measured humidity, it converts wet gas con... | |
Zetian technology is the only high and new technology company with a full set of intellectual property rights of flue gas monitoring. Its independent research and development products include ultravio | Overview Inhalable particle content is one of the most important indexes for measuring air quality. Combining years of experience in developing en... |
Same products
EQMS-200 VOCs Online Monitoring System | 卖方: HANGZHOU ZETIAN TECHNOLOGY CO., LTD | Overview EQMS-200 VOCs online monitoring system adopts PID (photoionization detector ) for gas de... | |
EM-5P Portable Flue Gas Analyzer | 卖方: HANGZHOU ZETIAN TECHNOLOGY CO., LTD | Overview EM-5P portable gas monitoring system mainly consists of gas monitoring sensors (SO2, NOx... | |
EM-5Hg Stack Mercury Continuous Monitoring System | 卖方: HANGZHOU ZETIAN TECHNOLOGY CO., LTD | Overview Based on cold vapor atomic fluorescence spectrophotometer technology, we have developed ... | |
EM-5 Flue Gas Analyzer | 卖方: HANGZHOU ZETIAN TECHNOLOGY CO., LTD | Overview EM-5 series flue online gas analyzeris a series of self-developed gas analysis products... | |
DPM-6000 PM Monitor PM2.5/PM10 | 卖方: HANGZHOU ZETIAN TECHNOLOGY CO., LTD | Overview Inhalable particle content is one of the most important indexes for measuring air qualit... |